37
6.8.2 System Alert - Event
Having ticked the
Syslog
/
SMTP
checkboxes, the event log/email alert will be sent to the
system log server and the SMTP server respectively. Also, Port event log/alert (link up,
link down, and both) can be sent to the system log server/SMTP server respectively by
setting the trigger condition.
System event selection:
There are 3 event types
—Device Cold Start,
Authentication Failure, and X-ring Topology Change. The checkboxes are not
available for ticking unless the
Syslog Client Mode
on the Syslog Configuration tab
and the
E-mail Alert
on the SMTP Configuration tab are enabled first.
System Restart:
When the device executes cold start action, the system will
issue the event log/email alert to the system log/SMTP server respectively.
Power Status:
When the power consumption about PoE was unstable, he
system will issue the event log/email alert to the system log/SMTP server
Summary of Contents for 2204F Series
Page 23: ...16 LC connector to the transceiver ...
Page 31: ...24 ...
Page 37: ...30 IP Addressing interface ...
Page 40: ...33 SNMP Agent Configuration interface ...
Page 48: ...41 ...
Page 52: ...45 Port Statistics interfac ...
Page 59: ...52 6 17 2Aggregator Status You can check the setting of Port aggregation in Status ...
Page 64: ...57 RSTP Port Configuration interface ...
Page 67: ...60 field and click Delete to remove it ...
Page 75: ...68 6 24 2Switch Status You can see the status of VLAN setting in this function ...
Page 80: ...73 highest priority Click Apply to have the configuration take effect ...
Page 91: ...84 6 26 3 3 Port Status You can monitor the port Authorized state in this function ...
Page 92: ...85 6 26 4 MAC Filtering You can block the un authorized MAC by switch in this function ...
Page 93: ...86 6 26 5 Port Security You can block the un authorized MAC by oer port in this function ...
Page 102: ...95 Straight through cables schematic Cross over cables schematic ...