background image

10

11

Diaphragm Cap

Diaphragm

ComfortFit™ Breast Flange

Assembling the Breastmilk Expression Set

Your Breastmilk Expression Set comes preassembled in Lansinoh product packaging. 
Clean Breastmilk Expression Set parts (except tubing and tubing connector) as 
described in the “Cleaning Instructions” section (see page 9). Once all parts are clean 
and completely dry, assemble the expression set as follows:

White Valve

5 oz Breastmilk 
Collection Container

Breast Flange Body

Pumping Tips

The most important part of successful pumping is the ability to trigger the let-down 
reflex. This is when your milk begins to flow freely. Warm wet compresses applied 
to the breasts and gentle, circular massaging of the breasts prior to and/or during 
a pumping session can help encourage this natural reflex. Thinking of or looking at 
your baby, or a photo of your baby if you are apart, can also be helpful.
Some moms can achieve more than one let-down during a pumping session. You 
may be able to achieve a second or third let-down during your pumping session 
by returning to the Stimulation phase by pressing the Stimulation/Expresion Toggle 
Button        .

How Long To Pump

Double pumping, compared to single pumping, will reduce the time you spend 
expressing your milk.  Breastmilk is produced on a supply and demand basis and 
by expressing your breastmilk regularly, your body will be stimulated and you will be 
able to maintain your milk supply. Just like with breastfeeding, it is not necessary to 
time your pumping sessions though you will get a better sense of the time it takes 
for your body to express your milk using a breast pump. If you have any breastfeed-
ing or breastpump related questions, consult with an International Board Certified 
Lactation Consultant (IBCLC), breastfeeding counselor, or other healthcare provider 
such as your primary physician.

Pumping and Feeding Tips

  You may pump one breast while nursing the baby on the other. This allows you 

to maximize pumping effectiveness using the let-down reflex stimulated by your 
baby’s sucking.

  You may pump into any standard sized screw-top bottle or container.

  Should you choose to use the Lansinoh bottle with a nipple of your own, please 

take the following precautions:

 

 

Always test the temperature of any liquid before feeding your baby.

 

 

Do not let a child take a bottle to bed or self-feed for long periods.

 

 

To prevent possible choking hazard, test strength of the nipple by pulling    

 

on the bulb portion. Discontinue use if any tear or crack appears.

 

 

You may also want to to try the Lansinoh

®

 mOmma

®

 bottle, featuring the    

 

NaturalWave™ nipple - which is clinically proven to help babies maintain    

 

established breastfeeding patterns - allowing your baby to go from breast    

 

to bottle and back.

The Adjustable Difference 

Your Lansinoh Affinity

®

 Pro Double Electric Breast Pump allows you to select     

suction levels and pumping rhythm mode separately to identify the settings that are 
most comfortable for you.  You would use the + and – symbols to adjust the suction 
level and set the power of the pump while using the pumping rhythm mode to set 
the pumping rhythm that is most comfortable and efficient for you      . 

Using the Lansinoh Affinity

®

 Pro 

Double Electric Breast Pump

1.

 Place purple diaphragm on top of breast flange body. Ensure lips on diaphragm 

fit tightly into gaps on the flange body per the illustration above. Then, place 
the diaphragm cap over the purple diaphragm ensuring that the slits in the 
diaphragm cap are aligned over the lips on the purple diaphragm. You will then 
need to twist the diaphragm cap to the right to ensure it is snugly in place, 

  enclosing the purple diaphragm.

2.

 Push ComfortFit™ breast flange into breast flange body.

3.

 Gently Push white valve into the bottom of breast flange body so that is securely 

attached. Your breast milk will flow through this white valve into the collection bottle.

 

Note:

 Use caution when handling and cleaning the small white valve (see page 9).

4.

 Screw collection container onto breast flange body.

5.

 Insert tubing into back of Diaphragm Cap; ensure tight fit.

6.

 Insert tubing connector, at end of tubing, into tubing input on the pump.

Summary of Contents for Affinity PRO

Page 1: ...1 AFFINITY PRO DOUBLE ELECTRIC BREAST PUMP INSTRUCTIONS FOR USE ...

Page 2: ... has a range of adjustable pumping rhythms and suc tion strengths that can be customized to your preferences a key difference in the Lansinoh Affinity Pro Double Electric Breast Pump If you have any questions please call our customer service department at 800 292 4794 or email customerservice lansinoh com Important Safeguards 4 Pump Diagram 6 Affinity Pro Breast Pump Parts 8 Cleaning Instructions ...

Page 3: ...p the cord away from heated surfaces Never use while sleeping or drowsy Never drop or insert any object into any opening or tubing Do not use this product if it is broken or any parts are missing Do not allow small children or pets to play with the pump unit AC adaptor etc Do not use outdoors with the AC adapter or operate where aerosol spray products are being used or where oxygen is being admini...

Page 4: ...crease Control Button 3 Pumping Rhythm Mode Toggle Button 4 LCD Display with Timer 5 Stimulation Expression Toggle Button 6 Suction Level Decrease Control Button 7 Stimulation Expression Phase Indicator Pump Diagram 1 2 3 4 5 6 7 11 10 9 8 12 Pump Diagram 13 Tubing input 14 Battery compartment for 6 AA batteries not included 15 AC adapter input AC Adapter AA Battery Compartment underneath pump 14 ...

Page 5: ... for 10 minutes Note Ensure you use enough water to keep parts afloat while boiling Note Do not boil the tubing and tubing connector 2 Remove all parts from water immediately after boiling 3 Completely air dry before assembly and next use Note Partially dried parts may affect operation of the pump Please ensure parts are completely dry before use Cleaning Set aside the tubing and tubing connector ...

Page 6: ...g effectiveness using the let down reflex stimulated by your baby s sucking You may pump into any standard sized screw top bottle or container Should you choose to use the Lansinoh bottle with a nipple of your own please take the following precautions Always test the temperature of any liquid before feeding your baby Do not let a child take a bottle to bed or self feed for long periods To prevent ...

Page 7: ...vided three different pumping rhythms so you can maximize your milk production and comfort You should try all three modes to determine which works best for you Note if at any time the suction on your breast reaches uncomfortable levels re duce the suction level by pressing the button on the left side of the LCD screen You can control suction levels in both phases by pressing the and buttons 4 The ...

Page 8: ...al safety can only be achieved when the breast pump is connected to the AC Power Adapter supplied with the product See Technical Data section page 15 16 Breastmilk Storage Guidelines Note DO NOT store breastmilk in freezer door The door tends to be the warmest part of the freezer Date all breastmilk and use the oldest breastmilk first Thawing Thaw frozen milk in the refrigerator or place the conta...

Page 9: ...Technical Data Warranty Limited Consumer Product Warranty United States This product is warranted to the original consumer purchaser the purchaser to be free from defects in material and workmanship which are not commercially acceptable for the period of one year from the date of purchase on the pump mechanism and the period of 90 days on all other product components Warranty coverage terminates i...

Page 10: ...s wireless home network devices mobile phones cordless telephones and their base stations walkie talkies can affect this equipment and should be kept at least a distance 3 5m away from the equipment Stacking This device should not be used adjacent to or stacked with other equipment And if adjacent or stacked use is necessary this device should be observed to verify normal operation in the configur...

Page 11: ...tor de leche eléctrico doble Lansinoh Affinity Pro es un artículo personal y por razones de higiene nunca se debe compartir ni revender a otras madres Cualquiera de esas acciones anulará la garantía Si usted tiene hepatitis B hepatitis C o el virus de inmunodeficiencia humana VIH extraer la leche materna por medio del Extractor eléctrico doble Lansinoh Affinity Pro no disminuirá ni eliminará el ri...

Page 12: ...ura 1 Si prefiere saltarse la Fase de estimulación de dos minutos que ya viene programada o si le baja la leche antes de los dos minutos presione el interruptor Estimulación extracción para cambiar a la Fase de extracción El Extractor de leche eléctrico doble Lansinoh Affinity Pro comenzará a funcionar en la Fase de estimulación y luego de dos minutos cambiará automáticamente a la Fase de extracci...

Page 13: ...a blanca Affinity Pro 2 2 extra 53401 b6 Biberón Affinity Pro de 5 oz 150 ml 2 50414 c Anillo 2 y disco 2 del biberón Affinity Pro 50406 d Adaptador cable de CA Affinity Pro 50409 e Base de biberón Affinity Pro 2 53404 Se incluyen dos válvulas blancas adicionales Puede adquirir por separado copas de succión de mayor tamaño Para solicitar piezas de repuesto o copas de succión de mayor tamaño llame ...

Page 14: ...de extracción de leche materna por primera vez desármelo y hierva por 10 minutos todas las piezas que entran en contacto con la leche incluye b1 b2 b3 b4 b5 y b6 Nota Asegúrese de usar agua suficiente para mantener todas las piezas a flote durante el hervor Nota No hierva el tubo ni su conector 2 Retire todas las piezas del agua inmediatamente después de hervirlas 3 Séquelas completamente antes de...

Page 15: ...veces durante su sesión de extracción si presiona el botón de estimulación extracción Cuánto debe durar la extracción Si en lugar de la extracción individual utiliza la doble disminuirá el tiempo que dedica a la extracción La producción de leche materna depende de la demanda por eso si extrae su leche regularmente su cuerpo estará estimulado y usted podrá mantener su suministro de leche Como suced...

Page 16: ... el adaptador de CA suministrado con el producto Ver la sección Datos técnicos en la página 32 33 Modo de uso del extractor Affinity Puede cambiar el ritmo de extracción del extractor presionando el botón Modo del ritmo de extracción Al presionar este botón cambiará el modo del ritmo de extracción Todas las mamás son diferentes es por ello que hemos establecido tres ritmos de extracción distintos ...

Page 17: ...terna en la puerta del congelador La puerta tiende a ser el lugar menos frío del congelador Anote la fecha en el recipiente y utilice primero la leche que lleva más tiempo en el congelador Descongelamiento de la leche Descongele la leche en la nevera o coloque el recipiente debajo de un chorro de agua fría y entibie la temperatura del agua gradualmente hasta que la leche se descongele La leche des...

Page 18: ...zas que no sean de Lansinoh pueden anular esta garantía EN LA MEDIDA EN QUE LA LEY LO PERMITA LANSINOH NO SE RESPONSABILIZARÁ POR NINGÚN DAÑO INCIDENTAL O INDIRECTO LO CUAL INCLUYE PERO NO SE LIMITA AL COSTO DE REEMPLAZO RESULTANTE DE LA INFRACCIÓN DE ALGUNA GARANTÍA ESCRITA O IMPLÍCITA Si desea presentar una reclamación en virtud de esta garantía deberá devolver el producto a Lansinoh Laboratorie...

Page 19: ...gún problema con este producto sírvase llamar gratis a la línea de servicio al cliente al 800 292 4794 Nuestro representante tendrá mucho gusto de ayudarle Distributed by Distribuido por Lansinoh Laboratories Inc Alexandria VA 22314 USA 800 292 4794 Lansinoh com Lansinoh is a registered trademark of Lansinoh Laboratories Inc 2012 Lansinoh Laboratories Inc All rights reserved Printed in Turkey Lans...