TF1100-EC/EI Manual
3
8. Metallurgy, Laboratory
9. Energy-conservation, economize on water
10. Food and medicine
11 Heat measures, Heat balance
12 On-the-spot check-up, standard, the data are judged, Pipeline leak detection
1.4 FEATURES
z
Advanced Digital Signal Processor technology and the MultiPulse
TM
transducer
technology
z
TF1100-EC is Clamp-on type, non-invasive system allows solids to pass through the
pipe within effect on meter. Y-strainers or filtering devices are not needed. TF1100-EI
is Insertion type, hot-tapped.
z
Digital cross-correlation technology
z
Since the sensors do not contact the liquid, fouling and maintenance are eliminated.
z
Provides easy and low cost installation by clamping on the outside of existing piping
systems.
z
Clear, user-friendly menu selections make TF1100 simple and convenient to use
z
A pair of sensors can satisfy different materials , wide different pipe diameters
z
4 Lines display, can display total flow, flow rate, velocity and meter run status. Parallel
operation of positive, negative and net flow totalizes with scale factor and 7 digit
display, while the output of totalize pulse and frequency output are transmitted via
open collector.
z
U.S., British and Metric measurement units are available. Meanwhile, almost
all-universal measurement units worldwide may be selected to meet customer’s
requirements.