Chapter 3:     Installation

To ensure a long-term and stable performance of the switch, please pay 

attention to the following before the installation.

Precautions

1) Safety Requirements:

3.1

Before cleaning the switch, cut off the power supply. Do not 

clean it by the waterish cloth, and never use any other liquid 

cleaning method.

Take waterproof measures during storage, transportation and 

operation of the equipment.

Use only the power cord provided with the switch.

Make  sure  the  voltage  of  the  power  supply  meets  the 

requirement of the input voltage of the switch.

Do not push any objects into the openings of the switch.

Ensure the vent hole is well ventilated and unblocked.

Do not open or remove the cover of the switch.

Figure 4. Switch Rear Panel Sketch

Grounding Terminal:

 

LP-SW2400S

 already comes with Lightning 

Protection Mechanism. You can also ground the switch through the 

PE (Protecting Earth) cable of AC cord or with Ground Cable. For 

detail information, please refer to section 

3.3 Connect to Ground

.

AC Power Socket:

 Connect the female connector of the power cord 

here, and the male connector to the AC power outlet. Please make 

sure the voltage of the power supply meets the requirement of the 

input voltage.

Rear Panel

2.2

The rear panel of 

LP-SW2400S

 features a power socket and a Grounding 

Terminal (marked with      ).

Summary of Contents for SW2400S

Page 1: ...full duplex bandwidth capability for high speed data processing Innovative Energy Smart technology saves power up to 70 Hassle free setup no configuration required 200 Mbps Small Form Factor can be in...

Page 2: ...ademarks of their respective holders No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without...

Page 3: ...1 2 Features 5 1 3 IEEE 802 1p QoS 6 1 4 Priority levels Table 7 Chapter 2 Identifying External Components 7 2 1 Front Panel 7 2 2 Rear Panel 8 Chapter 3 Installation 8 3 1 Precautions 8 3 2 Installa...

Page 4: ...ound in your box a One LP SW2400S switch b One power cord c Installation Guide d 1 Set of screws for attaching two L brackets used for mounting on 19 inch racks Make sure that the package contains the...

Page 5: ...ork to a 100Mbps network It will boost your network performance up to full duplex data transfer The LP SW2400S switch supports Energy Smart technology with power saving features to help make your netw...

Page 6: ...ets and the eight IEEE 802 1p priority tags defined by the standard are mapped to the four level queues used on the switch TC3 has the highest priority of the four priority level queues while TC0 has...

Page 7: ...r supply and connection Link Act LED The LED indicates Link Active status The corresponding LED indicator will light solid green when connected to a network device It flashes green when data is being...

Page 8: ...ement of the input voltage of the switch Do not push any objects into the openings of the switch Ensure the vent hole is well ventilated and unblocked Do not open or remove the cover of the switch Fig...

Page 9: ...witch will be accessible and that the cables can be easily connected Position the switch away from water and moisture sources Be sure to provide an acceptable temperature and humidity operating enviro...

Page 10: ...n 3 2 2 1 Secure the supplied rack mounting brackets to each side of the switch with supplied screws as illustrated in the following figure 4 Upturn the switch and connect it to the network devices wh...

Page 11: ...rackets are attached to the switch use suitable screws not provided to secure the brackets to the rack as illustrated in the following figure Figure 6 Attaching Brackets Figure 7 Mounting Switch 3 Con...

Page 12: ...g Bar or connecting to the Ground via the power cord Please connect the switch to ground in the optimum way according to your specific operation environment If the switch is installed in the equipment...

Page 13: ...he application and principle The power plug you get from the package and the socket in your situation will comply with the regulation in your country so they may differ from the figure above The LP SW...

Page 14: ...X UTP category 5 5e cable maximum 100m EIA TIA 568 100 STP maximum 100m Number of Ports 24 10 100Mbps Auto Negotiation RJ 45 ports Safety Emissions CE LED indicators Power Link Act Transfer Method Sto...

Page 15: ...power source is ON 2 The Link Act LED is not lit when a device is connected to the corresponding port Make sure that the cable connectors are firmly plugged into the switch and the device Make sure th...

Page 16: ...panies LanPro products are made in one of the following countries USA China Taiwan Thailand and Korea The exact country of origin is unknown LanPro and LanProfessional are US registered brands LanPro...

Reviews: