To avoid danger or damage incurred to the lens, do not touch the lens or sensor directly with your
fingers. 

Chapter 1     Notes and Safety Requirements 

1.1 Cautions and Notes 

User's Manual   |  CE210T HDMI Microscope

To avoid failure or electric shock hazard and so on, do not disassemble or modify the internal
structure of the device.

Do not plug in or unplug the Power connection port when hands are wet.

Do not use alcohol and other organic solvents to clean.

If the lens or sensor is dirty or damp, you should better use dry and non-linen fabric or professional
lens tissue to wipe them. To avoid scratches on the surface, do not touch the lens with your fingers.
Wipe the lens or sensor lightly.

The products are not specifically designed for an outdoor use. Do not expose it to outdoor
environment without any protection. Excessive temperature and humidity will damage the lens.
Please avoid using the product under the following environment: high temperature or high humidity
environment, places with direct sunlight, dirt or vibration and places near heat source.

Please use and store in the following environment:

         Operating temperature 

0

~ 40

         Storage temperature

-20

~ 60

         Operating Humidity

30~60%RH

         Storage Humidity

10~80%RH

If any foreign matter, water or liquid enter into the device by accident, disconnect the Power line
immediately. Please send it to the maintenance center and do not use the hair dryer to dry it by
yourself.

To prevent microscope from being tripped over or dropped, please put away the device’s connect
cable in use or standby.

To avoid electric shock by accident, please power off microscope before you move your computer or
laptop.

The cleanliness of the device lens will directly affect clarity degree of contents from the computer
screen during preview. Problems like various circles or spots on the screen may mostly be incurred
by dirt on the lens. When cleaning, please use professional lens tissue or other professional detergent
to clear the dirt on the lens.

Registered trademark and copyright: Copyright ownership of this produc belongs to Lanoptik
Technologies Ltd. Without written authorization of this company, any organizations or individuals
shall not photocopy, print, or translation to another language to any part of this document.

www.lanoptik.com

- 1 -

Summary of Contents for CE210T

Page 1: ...HDMI Microscope User s Manual www lanoptik com CE210T...

Page 2: ...ISCLAIMER 18 7 1 ARTICULATING ARM 6 7 2 FOCUS 6 7 3 ILLUMINATION 7 7 4 OPERATING MODE HDMI 7 7 4 1 Recording Media 8 7 4 2 Imaging Modes 8 7 4 3 Photo and Video Modes 8 7 4 4 Photo and Video Settings...

Page 3: ...s near heat source Please use and store in the following environment Operating temperature 0 40 Storage temperature 20 60 Operating Humidity 30 60 RH Storage Humidity 10 80 RH If any foreign matter wa...

Page 4: ...Chapter 2 Packing List User s Manual CE210T HDMI Microscope www lanoptik com 2 Adapter HDMI Microscope Screwdriver USB cable Screw HDMI cable Quick installation guide Wired controller...

Page 5: ...in the mode of photographing and recording activates the mode of cross line shortcut key 1 HDMI port Connect to the display with HDMI to realize signal transmission 2 USB port Connect to the adapter w...

Page 6: ...e 4 1 Name and Function for Each Part of Microscope PC connection Use the USB cable to connect microscope and computer 4 1 1 Connection Methods HDMI connection 1 As shown in Figure 1 use the HDMI cabl...

Page 7: ...fication 0 11X 0 79X Working Distance 44mm 230mm Depth of Field 0 8mm 6 5mm Observation Scope 7mmx4mm 49 4X to 45mmx25mm 4 5X Camera Resolution 2 0 MP 1920 x 1080 pixels Sensor Type Sony IMX291 CMOS c...

Page 8: ...ously using the locking knob Before adjusting the arm be sure to support the microscope with a hand Next loosen the locking knob until the arm joints are loose enough to easily move Position the micro...

Page 9: ...power the microscope using AC power plug the included AC USB adapter into an AC outlet then plug the USB cable s type A connector into the USB port on the adapter Alternatively a 5V USB power bank can...

Page 10: ...buttons for 2 seconds will activate specific functions depending on the mode While no menu is displayed pressing the right button will cycle through the imaging modes 7 4 3 Photo and Video Modes Phot...

Page 11: ...of view and attempts to achieve a middle grey Single Auto mode performs the same function as Auto but only at the time it is selected rather than continuously Manual allows you to select a value from...

Page 12: ...e vertically Color allows you to toggle the color mode between Normal color and Black White for a greyscale image Capture Mode determines allows you to set a delay between the time you press the captu...

Page 13: ...es the image Flip inverts the image vertically Color allows you to toggle the color mode between Normal color and Black White for a greyscale image Resolution sets the video image size and frame rate...

Page 14: ...en overlay to aid in measurements segmenting and counting Reticle1 is a simple crosshair Reticle2 is a grid of squares Reticle3 is a crosshair with concentric circles Frequency sets the capture freque...

Page 15: ...Chinese and Traditional Chinese Date Time allows you to set the current date and time which can be included in timestamps Default Setting will return the system s settings to their factory defaults Fo...

Page 16: ...h page in Photo and Video modes includes Display Time and Version Display Time determines whether the time will be displayed on screen This can be toggled between on and off Version displays the curre...

Page 17: ...ous file Press the bottom button to display the next file Press the left button to open the menu When the menu is closed the buttons control the following functions Press the top button to navigate up...

Page 18: ...h Simplified Chinese and Traditional Chinese Date Time allows you to set the current date and time which can be included in timestamps Default Setting will return the system s settings to their factor...

Page 19: ...ove the power switch to the I on position Once a PC connection is detected the microscope will enter PC mode If the microscope is connected to an HDMI display a blue screen will be displayed stating t...

Page 20: ...ease carefully read the instructions disclaimers and safety instructions provided with this product before using it The company reserves the right to update the above documents Please operate the prod...

Page 21: ...reet Lejia Road Baiyun District Guangzhou China 510400 Phone 86 20 3898 6017 Fax 86 20 3847 6076 Website http www lanoptik com Email info lanoptik com Specifications are subject to change without any...

Reviews: