
8
peuvent causer des pannes totales ou intermittentes. Suivez les procédures de prévention d’ESD lors du
retrait et du remplacement de composants.
Portez un bracelet anti-ESD et veillez à ce qu’il soit bien au contact de la peau. Si aucun bracelet n’est
disponible, reliez votre corps à la terre en touchant la partie métallique du châssis.
Vérifiez régulièrement la valeur de résistance du bracelet antistatique, qui doit être comprise entre 1 et
10 mégohms (Mohms).
Mounting Installation Precautions
The following should be put into consideration for rack-mount or similar mounting installations:
Do not install and/or operate this unit in any place that flammable objects are stored or used in.
The installation of this product must be performed by trained specialists; otherwise, a non-specialist
might create the risk of the system’s falling to the ground or other damages.
Lanner Electronics Inc. shall not be held liable for any losses resulting from insufficient strength for
supporting the system or use of inappropriate installation components.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration
should be given to installing the equipment in an environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow
required for safe operation of the equipment is not compromised.
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition
is not achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
Reliable Grounding - Reliable grounding of rack mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch circuit (e.g.
use of power strips).
Summary of Contents for NCA-5710
Page 1: ...1 NCA 5710 User Manual Version 1 2 Date of Release 2019 06 11 Network Appliance Platform...
Page 58: ...Chapter 3 Software Setup 58...
Page 61: ...NCA 5710 User Manual 61 Trusted Computing TPM2 0...
Page 63: ...NCA 5710 User Manual 63 Trusted Computing PTT Enable...
Page 65: ...NCA 5710 User Manual 65 Super IO Configuration...
Page 80: ...NCA 5710 User Manual 80 NVMe Configuration USB Configuration...
Page 89: ...Chapter 3 Software Setup 89 Server ME Configuration...
Page 92: ...NCA 5710 User Manual 92 Processor Configuration...
Page 101: ...Chapter 3 Software Setup 101 Socket0 PcieBr1D00F0 Port 1A 1C 2A 2C...
Page 113: ...Chapter 3 Software Setup 113 View System Event Log...