APPENDIX C: PROGRAMMING GENERATION 3
LAN BYPASS
The bypass function is used to link two independent Ethernet ports when the system crashes or powers off.
This means if your system is equipped with a LAN Bypass function, a condition in your system will not
interrupt your network traffic. Different from the previous two generations (Gen1 and Gen2), the Lanner
Bypass Gen 3 employs a programming method to control the bypass function by software. There are typically
two communication status for the bypass function, one is “Normal” and another is “Bypass” status.
Furthermore, the Lanner Bypass software is capable to control the bypass status in the following 3 instances.
1. When the system powers off, it can be forced to enable the LAN Bypass function.
2. When the system is in the just-on state which is a brief moment when it powers up.
3. When the system is running
Please refer to the LAN_Bypass_Watchdog folder on the Driver and Manual CD.
Lanner bypass possess the following features:
1. Communication through SMBUS (I2C)
2. Independent bypass status control for each pair up to a total of 4 pairs
3. Lanner Bypass Modules can bypass systems Ethernet ports on a host system during three instances: Just-
on (Just-on is the brief moment when the internal power supply turns on and booting process starts), System
off, or upon software request (during run-time).
4. Software programmable bypass or normal mode
5. Software programmable timer interval:
- JUST-ON watchdog timer, used during JUST-ON, has timer setting of 5~1275 seconds of timer interval.
- Run-Time watchdog timer, used during run-time, has setting of 1~255 seconds of timer interval.
6. Multiple Watchdog Timers:
-Two for run-time: It is designed to give you a more variety of controls of the bypass on port basis. By using
dedicated watchdogs for different pairs of bypass, you have the flexibility to manage the bypass status for
them differently.
-One for just-on: It is designed to give you the precise control of the bypass during this phase. You can use
this timer to delay enabling the bypass in just-on state.
For sample LAN bypass code and the Bypass Manual, see the
LAN_Bypass
folder on the
Driver and Manual
CD or
http://www.lannerinc.com/download-center/
download
center
and look for
Lanner LAN Bypass Watchdog User Manua
l under the
Accessories folder
.
For a description of the physical LAN ports equipped with this function, refer to
Front Panel Features
in
Chapter1 Introduction
.
Summary of Contents for NCA-5210
Page 1: ...NCA 5210 User Manual Version 1 7 Date of Release 2021 09 16 Network Appliance Platform...
Page 31: ...31 3 Slide and pull the top cover backwards a little bit 4 Lift the top compartment...
Page 53: ...53 HW Monitor This option allows you to view hardware health status...
Page 65: ...65 SATA1 enable or disable the SATA1 port SATA2 enable or disable the SATA2 port...
Page 66: ...66 SATA3 enable or disable the SATA3 port SATA4 enable or disable the SATA4 port...
Page 68: ...68 You may select Enabled Disabled or Auto...
Page 71: ...71 Memory Configuration Memory Configuration provides memory configuration parameters...
Page 81: ...81 Discard Changes and Exit exit system setup without saving the configuration changes...
Page 82: ...82 Restore Defaults restore load factory default setting for all setup parameters...
Page 83: ...83 Boot Override You may select a device under Boot Override for this function...
Page 84: ...84...
Page 93: ...93...