MAINTENANCE & CLEANING CONT’D 

 

Use recommended Pane Bella grill cleaner in a diluted form for cast iron 
plates. This process will clean the grill surface and not strip the grill to the 
metal thus removing seasoned finish. 

 

For grills with heavy carbon build-up, from continuous weeks of use without 
cleaning, it may be necessary to scrape the grill thoroughly and use 
recommended grill cleaner full strength, stripping finish to the metal. Only 
then it may be necessary to “re-season” after this procedure. 

 

Heavy carbon build-up on grill plates will negatively affect surface 
temperature and grill performance. 

 

 

9.2 Component Access 

The thermostats, timers, indicator lamps, power cord and lower cooking surface 
heating elements are located inside the body of the grill.  Access to these 
components is achieved through the bottom of the unit.  Gently tip the entire grill 
onto its side and remove the four screws holding the bottom to the body.  Take care 
not to damage the power cord exiting the rear of the grill. 

The upper surface heating elements are located in the upper grill assembly.  To 
access, remove the four screws and one knob holding the curved cover onto the 
upper assembly. 

The upper cooking surface assist springs are located at the top rear of the unit under 
the handle pilot cover.  To access, remove one screw located at the back of the 
cover then slide the cover to one side. 

The grill temperature will vary by as much as 50 degrees from the bottom to the top 
of the groove.  Take all temperatures at the bottom of the groove. 

Allow the grill to operate at temperature for 1 hour before attempting to check the 
calibration. 

Place a surface thermometer in the center of each lower cooking section at the 
bottom of the groove. 

Record the temperatures at which the thermostat indicator lamp just turns On then 
Off, disregard any temperatures other than On and Off. 

Average the On and Off temperatures, if the temperature average is within 25 
degrees of the set temperature the thermostat need not be replaced.

 

 

 

Summary of Contents for PB-24

Page 1: ...ll Creek Parkway Everett WA 98203 Part Number 60801 17 Phone 425 349 2400 Fax 425 349 2733 WWW LANGWORLD COM Copyright 1999 1 Installation Operation Concept Training Maintenance Troubleshooting Model...

Page 2: ...IDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE POST IN A PROMINENT LOCATION WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH REA...

Page 3: ...E 1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 EQUIPMENT DESCRIPTION 6 4 UNPACKING 8 5 INSTALLATION 9 6 INITIAL START UP 11 7 OPERATION 12 8 MAINTENANCE CLEANING PROCEDURES 14 9 TROUBLESHOOTING 16 10 PARTS...

Page 4: ...USE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located on the back of each griddle The griddle voltage watta...

Page 5: ...ING SURFACE WHILE THE GRIDDLE IS HOT THE GRILL IS MADE OF CAST IRON AND MAY CRACK FROM A RAPID TEMPERATURE CHANGE NOTICE Service on this or any other LANG appliance must be performed by qualified pers...

Page 6: ...66cm Wide The grill surface is made of an upper and lower gray iron casting grill surface Operation Each twelve inch section has its own thermostat and timer Controls Each PANE BELLA Grill comes with...

Page 7: ...ny components such as a vent hood grease extractors and or fire extinguisher systems must conform to the there applicable nationally recognized installation standards Electrical Specifications ELECTRI...

Page 8: ...ractical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways 4 3 Un crating The griddle will arrive completely assembled in...

Page 9: ...such as a vent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards 5 1 Electrical Connection Follow the recep...

Page 10: ...tion of any components such as a vent hood grease extractors and or fire extinguisher systems must conform to the there applicable nationally recognized installation standards 5 3 Hood Stop Place the...

Page 11: ...mplate out of the copy 2 Place the template so that the TOP is at the top of the label and that the template is resting between the top and bottom metal trim pieces and between the existing timers 3 H...

Page 12: ...roduct sticking To season set the dial to position 2 Once at temperature the indicator lamp will go Off spray the upper and lower cooking surfaces with a non salted vegetable oil such as Pam Allow the...

Page 13: ...glow until the cooking surfaces reach the set temperature Once at the set temperature the indicator lamp will go Off Conservation Hint Close the upper cooking surfaces during preheat and idle times Th...

Page 14: ...tips to keep your grill looking like new After the seasoning process use any vegetable non stick spray sparingly maybe not ever Vegetable oil sprayed on the grill surface continually throughout the da...

Page 15: ...holding the bottom to the body Take care not to damage the power cord exiting the rear of the grill The upper surface heating elements are located in the upper grill assembly To access remove the four...

Page 16: ...e checked To test for a possible cause refer to the TEST section and locate the Possible Cause then refer to test to identify test procedures SYMPTON POSSIBLE CAUSE Hood not getting hot Failed element...

Page 17: ...ING ANY PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY POSSIBLE CAUSE TEST Product not being removed when timer sounds No test available operational condition No power Check for correct inco...

Page 18: ...PB 24 4 3 6 7 9 8 19 9 10 19 20 21 22 25 43 45 46...

Page 19: ...ed PB 24G 2F 50800 98 2 Plate Grill Lower Smooth PB 24 14 2P 51001 31 2 Spring Upper Grill Assist 15 2R 70701 52 2 Knob Crumb Tray 16 2R Y7555 4 Foot 17 2A 73500 04 8 Collar Set 1 2 I D STL 7 8 18 I9...

Page 20: ...Pin 3 16 x 1 3 8 PLTD NI 2H PB 812 2 Hood Insulation NI 2K 70801 21 1 Strain Relief Bushing Heyco NI 2H PB 719 2 Bottom Plate Insulation Double Bottom NI 2J 30801 02 2 Timer Mechanical 15 Minute NI 2...

Page 21: ...20 WIRING DIAGRAM PB 24...

Page 22: ...21 WIRING DIAGRAM PB 12 120V...

Page 23: ...22 WIRING DIAGRAM PB 12 208 240V...

Page 24: ...23 NOTES...