INSTALLATION CONT’D

 

IF SETTING THE UNIT ON A COUNTER: 

Split the back into two pieces. 

Remove the screws from the rear of the cheese-melter; screw the stainless steel 
portion of the back to the cheese-melter with the off-set at the top. 

Reinstall the two back halves together and replace the screws around the edge. 

When installing on a counter the legs 

must be

 installed before using the unit, as 

they will provide the required clearance for the bottom of the unit. 

Place the unit in location, and level using leg adjustments. 

Observe minimum clearances at all times. 

4.1 Electrical Connection 

Electrical service routing may be made through either of two 1 1/4 inch knockouts 
provided.  One may be found along the bottom edge of the back panel.  The second 
knockout is located on the bottom of the unit. 

4.2 Cheese-melter Voltage 

The model MM36C-3-CLS Cheese-melter is shipped from the factory wired for 220 
volts.   

4.3 Phasing 

All cheese-melters are shipped from the factory set up for a 

single phase

 service. 

4.4 Elements 

Elements for all electric Cheese-melters are shipped, packaged separately, within the 
shipping crate. 

These should be inspected upon opening of the shipping carton.  If an element is found 
damaged or broken, notify the Freight Company immediately.   

Installation of the elements is not a warrantable expense.  The installer or a qualified 
service company should complete installation.  Damage to elements or equipment 
resulting from incorrect or improper installation will be the responsibility of the 
equipment owner or individual installing elements. 

WARNING: 

DUE TO THE HIGH HEAT EXPOSURE EXPERIENCED AT 
CONNECTIONS, USE OF NON-CERAMIC WIRE NUTS IS NOT 
RECOMMENDED.  DAMAGE TO EQUIPMENT, OR INJURY TO 
PERSONNEL MAY RESULT. 

 

 

CHEESE-MELTER SPECIFICATIONS 

NOMINAL AMPS PER LINE 

SINGLE PHASE 

MODEL 

NUMBER 

TOTAL 

kW 

240 VOLT 

WEIGHT 

MM36C-I-CLS  

 

3.6 15 

135 

lbs. 

Summary of Contents for MM36C-I-CLS

Page 1: ...y 6500 Merrill Creek Parkway Everett WA 98203 Phone 425 349 2400 Fax 425 349 2733 WWW LANGWORLD COM Copyright 2000 Installation Operation Maintenance Troubleshooting Model MM36C I CLS Electric Cruise...

Page 2: ...NING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALL...

Page 3: ...APTER PAGE 1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 UNPACKING 6 4 INSTALLATION 7 5 OPERATION 9 6 CLEANING MAINTENANCE PROCEDURES 10 7 TROUBLESHOOTING 11 8 PARTS LISTS 13 9 EXPLODED VIEW 14 10 WIRING DIA...

Page 4: ...DONE BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTI...

Page 5: ...this or any other LANG appliance must be performed by qualified personnel only Consult your authorized service station directory or call the factory at 1 800 224 LANG 5264 or WWW LANGWORLD COM for th...

Page 6: ...normally associated with moving it through hallways and doorways 3 3 Un crating The cheese melter will arrive completely assembled inside a wood frame covered by cardboard box and strapped to a skid R...

Page 7: ...of the unit in the lower front corner The voltage wattage serial number wire size and clearance specifications are on the data plate This information should be carefully read and understood before pro...

Page 8: ...model MM36C 3 CLS Cheese melter is shipped from the factory wired for 220 volts 4 3 Phasing All cheese melters are shipped from the factory set up for a single phase service 4 4 Elements Elements for...

Page 9: ...choice of cooking positions for a variety of applications The top position is very hot and can be used for quick browning and toasting with the heat decreasing at each lower position In order to chan...

Page 10: ...ater solution Discoloration or heat tint may be removed with any of the following cleaners Penny Bright Copper Bright Du Bois Temp or Past Nu Steel Always apply these cleaners when the unit is cold an...

Page 11: ...of failure then to the Possible Cause for the items to be checked To test for a possible cause refer to the TEST section and locate the Possible Cause then refer to test to identify test procedures SY...

Page 12: ...Y PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY If an item on the list is followed by an asterisk the work should be done by a factory authorized service representative Possible Cause TEST...

Page 13: ...06 51 1 14 MM36 Rack 50200 14 1 15 Black Threaded Boot for Metal Toggle Switch 30303 15 1 16 Metal Handle Toggle Switch On On DPDT 30303 14 1 17 Panel Assembly MMCL 191 1 1 18 2 Pole Contactor 30 Amp...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19 WIRING DIAGRAM...

Page 20: ...ted by the repair Quartz elements are warranted for ninety 90 days from the date of installation II Damage during shipment is to be reported to the carrier is not covered under this warranty and is th...

Reviews: