Troubleshooting
50
30.11.12
10 Troubleshooting
10.1 Troubleshooting Table
WARNING
Risk of injury caused by defective
parts!
Operating with defective parts
could result in serious injury.
•
Stop operating with defective
parts and return the positioning
system for repair.
Problem
Cause
Measure
Executed by
Positioning
system does not
move
inadequate
electrical
connection
check
connection
between
controller and
positioning
system
qualified
electrician
check
configuration of
the COM-port at
the PC
qualified
electrician
missing voltage
switch on power
supply
qualified
electrician
Vibrations
wrong control
parameter
check control
parameter
qualified
electrician
Unusual friction
noise
particle on
bearing and/or
ball bearing
contact FMD
service
qualified
personnel
insufficient
geometrical
tolerances
check assembly,
adjust applied
devices
qualified
personnel