background image

19

PARTS LIST

 

       

May 14, 2014, Rev A

Some items are included for illustrative purposes only and in certain instances may not be available.

 IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED 

 

                        PAGE   1

 

          INCLUDE MODEL AND SERIAL NUMBER 

 

 

 

            

               

OF     1

Model: 148ZS EnviroZone Selectronic Griddle

Fig No.

Part Number

Quantity

Description

Application

1

K9-142-201-343

1

GRIDDLE PLATE ASSY-4’ ZTD

148ZSD

K9-142-201-43

GRIDDLE PLATE ASSY - 4’ZT

148ZS

2

2N-11030-30

4

ELMNT GRID 208V 1257W

148ZS

2N-11030-30-1

PERIMETER ELEMENT-30”D

148ZSD

3

2N-11030-29

4

ELE GRD 208/240V4.5KW/6KW

148ZS

2N-11030-29-1

DUAL VOLTAGE ELEMENT-30”D

148ZSD

4

K9-XL-429

4

ELEMENT PLATE GUIDE WLDMT

148ZS

K9-XL-429-1

148ZSD

5

K9-XL-424-1

4

ELEMENT PAN INSULATION

148ZS

K9-XL-424-2

ELEMENT PAN INUSL 30” DEEP

148ZSD

6

K9-XL-434-1

4

ELEMENT PAN SPOTWELD

148ZS

K9-XL-434-2

ELEMENT PAN SPOTWELD-30”D

148ZSD

7

K9-XL-532

24

BOLT AND SCREW ASSY

8

2E-41100-17

4

TEMP PROBE SEL LG GRIDDLE

9

K9-142-441

4

RTD PROBE HOLDER

10

2C-20102-12

35

SCRW PHD ST 10-32X3/8

11

2C-20301-11

18

NUT HEX 8-32 PLTD

12

2E-30701-04

3

CONTC 2POLE 30A 24VAC

13

K9-142-152-W41

4

CONTACTOR BRACKET

14

2E-40101-W19

4

CIRBD SI TEMP CONTROL

15

2K-70801-07

12

SPACER SUPPORT 1/2LG

16

2E-30304-22

4

SWTCB175-450°F w/

41100-13

17

2C-20602-04

5

TINNERMAN SPD NUT 1/8 DIA

18

K9-142-242

1

FRONT PNL WELD ASSY, LEFT ZS

19

2M-60301-43

1

DIE CAST PLT LANG SATIN

20

2M-60301-29

4

PNLLBL SELCT SWTDIAL 450o

21

2R-70701-28

4

KNB BLK 1/4BUSH2SETSCW@90

22

Y9-31601-01-1

5

PILOT LT 250V W/TIN CLIP

23

K9-141-161-3W1

2

GREASE DRAWER SLIDE WELD

148ZSD

K9-141-161-W1

148ZS

24

K9-50303-18

2

GREASE DRAWER-EZONE GRID

25

2I-05-07-0013

5

BOOT SWITCH

26

2M-12-07-0038

5

LABEL ON & OFF

27

Z1-70-07-0343

5

SWITCH GUARD

28

2E-30303-06

5

SWT TOG ON-ON DPDT BLK

29

K9-142-232-21

1

FRONT PANEL WELD ASSY, RIGHT

K9-142-232-61

FRONT PANEL WELD ASSY, CENTER ZS

30

K9-142-151-W2

1

24V XFMR AND BRKT ASSY

31

2E-31400-07

1

XFORMR120-208-240/24V40VA

32

2A-72500-20

4

LEG 10.25 WITH ADJ HEX

33

K9-XL-507-2

1

REAR COVER - ZT

34

2C-20103-01

2

SCRW SM PLT 10X7/8 PHIL

35

2E-30500-03

1

TRM STRIP 6POLE 30A 300V

2E-30500-22

TEM STRIP 8POLE 50A/250V

NI

2E-30500-07

1

TRM BLOCK 3PLELRGE 125AM

NI

2M-61114-W71

0

W/D ZS SEL GRID 208/240

Summary of Contents for EnviroZone 124ZD

Page 1: ...IL2799 ENVIROZONE SELECTRONIC ELECTRIC GRIDDLE Commercial 124ZS D 136ZS D 148ZS D 160ZS D 172ZS D Installation and Operation Instructions 2M W1992 Rev B 03 2018 136ZS...

Page 2: ...SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Lang reserves the right to change s...

Page 3: ...shooting Symptoms Possible Causes 12 Possible Causes Test 13 Wiring Diagram 14 Exploded View Parts List 15 20 PROBLEMS QUESTIONS or CONCERNS Before you proceed consult you authorized Lang service agen...

Page 4: ...x 28 2 724 lbs 800 lbs 381mm x 1830mm x 717mm 329 kg 364 kg EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS Model Volts AC Hz Ph Kw TOT Amp 1PH Supply Wire 1 PH Amp 3 Ph Supply Wire 3 PH Kw TOT Amp...

Page 5: ...period and limitations defined in this warranty will at Lang s discretion have the parts replaced or repaired by Lang or a Lang authorized service agency THIS WARRANTY IS SUBJECT TO ALL LISTED CONDITI...

Page 6: ...ts intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways Un crating The griddle will arrive co...

Page 7: ...OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located behind access panel between controls and grease drawer The grill voltage wattage...

Page 8: ...e 208 240 griddle is a dual voltage design Jumper wires on terminal strip next to the main power supply connection determine the griddle voltage For a 208 volt power supply leave the jumpers in place...

Page 9: ...C for another hour and repeat this until it is at 450 F 232 C for hour The unit may emit a small amount of smoke as the cooking surface passes the 300 F 148 C point Do not be alarmed as the smoke is c...

Page 10: ...ct is loaded to the side front or back of the temperature sensor the thermostat will react to the temperature change much slower During slow periods with minimal loads do not load directly over the th...

Page 11: ...surface sparkling clean and performing at top efficiency DO NOT allow grease to accumulate as it will carbonize and become difficult to remove To prevent this condition the following cleaning suggesti...

Page 12: ...locate the possible cause then refer to test to identify test procedures SYMPTOM POSSIBLE CAUSE Whole Griddle will not heat No Power to Griddle Failed Power switch Failed Transformer One Section will...

Page 13: ...F ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES POSSIBLE CAU...

Page 14: ...OOKUP 208V 240V INSTALL JUMPER ITEM 4 REMOVE JUMPER ITEM 4 MODEL VOLTAGE KW AMP TOTALS 3 PHASE AMPS 1 PHASE SERVICE CONNECTIONS THREE PHASE SERVICE CONNECTIONS SINGLE PHASE L1 L2 L2 L3 L1 L3 TOTAL L1...

Page 15: ...15...

Page 16: ...ric Enviro Zone Selectronic Griddle 1 2 4 5 6 7 9 11 12 13 14 18 23 25 26 27 29 28 11 31 30 10 32 33 34 35 10 24 10 19 20 21 22 15 17 16 10 8 10 3 SK2763 Rev 3 10 14 Model 136ZS Electric EnviroZone Se...

Page 17: ...9 142 441 2 RTD PROBE HOLDER 10 2C 20102 12 22 SCRW PHD ST 10 32X3 8 11 2C 20301 11 14 NUT HEX 8 32 PLTD 12 2E 30701 04 2 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 2 CONTACTOR BRACKET 14 2E 40101 W19 2...

Page 18: ...RTD PROBE HOLDER 10 2C 20102 12 25 SCRW PHD ST 10 32X3 8 11 2C 20301 11 14 NUT HEX 8 32 PLTD 12 2E 30701 04 3 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 3 CONTACTOR BRACKET 14 2E 40101 W19 3 CIRBD SI TE...

Page 19: ...3 8 11 2C 20301 11 18 NUT HEX 8 32 PLTD 12 2E 30701 04 3 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 4 CONTACTOR BRACKET 14 2E 40101 W19 4 CIRBD SI TEMP CONTROL 15 2K 70801 07 12 SPACER SUPPORT 1 2LG 16 2...

Page 20: ...0 2C 20102 12 42 SCRW PHD ST 10 32X3 8 11 2C 20301 11 24 NUT HEX 8 32 PLTD 12 2E 30701 04 5 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 5 CONTACTOR BRACKET 14 2E 40101 W19 5 CIRBD SI TEMP CONTROL 15 2K 70...

Page 21: ...301 11 28 NUT HEX 8 32 PLTD 12 2E 30701 04 6 CONTC 2POLE 30A 24VAC 13 K9 142 152 W41 6 CONTACTOR BRACKET 14 2E 40101 W19 6 CIRBD SI TEMP CONTROL 15 2K 70801 07 18 SPACER SUPPORT 1 2LG 16 2E 30304 22 6...

Page 22: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Lang Wells Toastmaster 265 Hobson Street Smithville Tennessee 37166 U S A 314 678 6303 www langworld com www star mfg com...