Possible Cause

TEST

Product is cooked too long

 

No test available, operational condition

Failed thermostat

 

Check poles on thermostat for continuity

Failed element

 

Remove the wires and check for continuity
across the element

Failed heat contactor

 

Remove the wires from the contactor coil and
check for continuity across the contactor coil
connection

 

Ensure the contactor moveable points move
freely up and down

 

Check for 24 volts at the contactor coil when
the computer is running

*

Failed temperature sensor

 

Check resistance of sensor for accuracy

Failed pilot light

 

Check light for resistance

Failed transformer

 

Check coils on transformer for correct
resistance

CAUTION:

   

USE OF ANY REPLACEMENT PARTS OTHER THAN
THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED
DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE
OPERATOR AND DAMAGE TO THE EQUIPMENT AND
WILL VOID ALL WARRANTIES.

Summary of Contents for CLR36R-GB-S

Page 1: ...ek Parkway Everett WA 98203 Phone 425 349 2400 Fax 425 349 2733 WWW LANGWORLD COM Copyright 2000 Installation Operation Maintenance Troubleshooting Model CLR36R GB S Electric Cruise Line Grooved Gridd...

Page 2: ...NING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALL...

Page 3: ...PTER PAGE 1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 UNPACKING 6 4 INSTALLATION 7 5 INITIAL START UP 8 6 OPERATION 9 7 CLEANING 10 8 TROUBLESHOOTING 11 9 PARTS LISTS 13 10 EXPLODED VIEWS 15 11 WIRING DIAG...

Page 4: ...WITH ELECTRICITY IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located behind t...

Page 5: ...this or any other LANG appliance must be performed by qualified personnel only Consult your authorized service station directory or call the factory at 1 800 224 LANG 5264 or WWW LANGWORLD COM for th...

Page 6: ...emove the wood crating carefully Improper use of tools can result in damage to the equipment Remove and discard the plastic wrap Desiccant bags on top of the range should also be discarded Protective...

Page 7: ...National State and locally recognized installation standards 4 1 Electrical Connection with an Overhead Switch Box Electrical connection must be accomplished with 3 separate connections on remote swi...

Page 8: ...from in and around the Range The smoke may be repeated somewhere around 350 Preservation oils and oil accumulated during manufacturing may be coming off as smoke in these temperature ranges Do no be...

Page 9: ...ory baking can be done The oven will not bake uniformly if not sufficiently preheated After preheating let the oven cycle 2 or 3 times to ensure complete heating of the entire oven cavity The Roasting...

Page 10: ...ith the grooved griddle cleaning tool to remove any carbonized grease The griddle surface should be cleaned and re seasoned Use a griddle stone griddle pad or liquid cleaner Rub with the grain of the...

Page 11: ...e then refer to test to identify test procedures SYMPTOM POSSIBLE CAUSE Indicator is not lit No power to unit Failed switch Failed pilot light Range will not heat Failed element Switch is not ON Faile...

Page 12: ...is cooked too long No test available operational condition Failed thermostat Check poles on thermostat for continuity Failed element Remove the wires and check for continuity across the element Faile...

Page 13: ...4 Stainless Steel Hex Head Cap Screw 3 8 16 20104 53 1 15 Spring Piston XLHCL 119 1 16 Hood Type Compression Spring 51002 01 1 17 Spring Tube Assembly CLR 480 1 18 Spring Tube Cap and Bearing Retaine...

Page 14: ...e Plate specify top grooves location if desired CLR 520 1 42 Element Pan CLR 513 4 43 Inner Element 440V 1850W 11045 09 4 44 Outer Element 440V 1650W 11045 08 4 45 Element Plate CLR 511 4 46 Element P...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21 WIRING DIAGRAM...

Page 22: ...ted by the repair Quartz elements are warranted for ninety 90 days from the date of installation II Damage during shipment is to be reported to the carrier is not covered under this warranty and is th...

Reviews: