This appliance and its pressure regulator must be isolated from the gas supply piping system by closing 
its individual manual shutoff valve during any pressure testing of the gas supply piping system at test  
pressures equal to or less than 1/2 PSIG (3.45KPA). For the protection of you and your property, we  
recommend a qualified installing agency install this unit. They should be familiar with gas installations  
and your local gas company requirements. In any case, your gas company should be called to approve  
the final installation. Detailed instructions should be posted in a prominent location, to be followed  
in the event the operator smells gas. Obtain the instructions from the local gas supplier.

GAS PIPING

Gas piping will need to be installed correctly and be an appropriate size to provide a supply of gas  
sufficient to meet the full gas input of the appliance. If the appliance is to be connected to existing  
piping, it will need to be checked to determine if it has adequate capacity before installation. Joint  
compound should be used sparingly and only on the male threads of the pipe joints. Any compounds  
used will need to be resistant to LP and Natural gases. 

Any loose dirt or metal particles which are allowed to enter the gas lines on this appliance will damage  
the valve and affect its operation. When installing this appliance, all pipe and fittings must be free from  
loose dirt. 

MANUAL SHUT-OFF VALVE

A manual shut-off valve should be installed upstream from the union and within six [6] feet (1.829 m)  
of this unit. 

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with each griddle. It should be connected to the inlet  
pipe at the rear of the unit. The gas supply line is then connected to it. It is shipped set for 5-inch  
water column manifold pressure for use with natural gas. For LP use, the pressure will need to be  
adjusted as directed in the steps below.  

GAS CONVERSION

This griddle is equipped with fixed orifice hoods and is shipped from the factory for use on natural
gas or LP. To convert to LP [propane] from natural gas [or vice versa], install the alternate burner  
orifice hoods located in the grease drawer, using the following procedure.

i. Remove the front panel by removing the screws located on the front and bottom.

ii. Remove the burners from the orifice hoods. This is accomplished by removing the burner mounting   
    screws and sliding the burners off the hoods.

iii. Remove the natural gas orifice hoods and install the propane hoods the were provided.
iv. Reinstall the burners.

v. Reinstall the front panel.

vi. Remove the slotted, or hex-headed, plug from the pressure regulator. Invert the plug and reinstall.

 The letters “LP” should now be visible on the plug. The regulator is now set for 10-inch water column   
  manifold pressure. To check pressure, a 1/8-inch pipe plug on the manifold can be removed for  
  attaching a pressure gauge. 

Summary of Contents for 424T

Page 1: ...Exploded view s as well as any available parts list s and wiring diagram s pertaining to the unit s covered by this manual are also included This manual must be read and understood by all persons usin...

Page 2: ...product within 50 miles 80 5 km of an authorized service agency Time and expense charges for anything beyond that distance will be the reponsibility of the owner All labor will need to be performed du...

Page 3: ...2M Z22112 Rev Owner s Manual for Lang 4xx Series Gas Griddles TABLE OF CONTENTS Warranty i General Information 1 Installation and Gas Connection 2 4 Daily Operation 5 Specifications 6...

Page 4: ...iii NOTES...

Page 5: ...rmation in the above elds ready when you call to ensure a faster service Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability Due to periodic change...

Page 6: ...e first time ensure to clean the unit properly Refer to the Daily Operation section for cleaning instructions VENTILATION Make certain not to obstruct the flow of combustion and ventilation air Provis...

Page 7: ...appliance will damage the valve and affect its operation When installing this appliance all pipe and fittings must be free from loose dirt MANUAL SHUT OFF VALVE A manual shut off valve should be insta...

Page 8: ...d impurities are burned off Use the following procedure to light all pilots i Turn off the main valve to the unit and wait 5 minutes to clear gas ii Turn off all knobs and pilot valves iii Turn on the...

Page 9: ...wer is removed by pulling forward until it is released from its track The grease pan on the front is hot and contains hot grease Take care when removing and emptying the tray The tray should be checke...

Page 10: ...556 lb 252 kg 472 18 in 457 mm 72 1 in 1 83 m 33 7 in 856 mm 180 000 120 2 240 787 lb 357 kg 642 lb 291 kg CLEARANCES The sides and back must be at least six 6 inches 152 mm from any wall or surface...

Page 11: ...2M Z21001 Rev Owner s Manual for IRCS4 Impingement Radiant Split Belt Conveyor Toaster 7 2M Z22112 Rev Owner s Manual for Lang 4xx Series Gas Griddles...

Page 12: ...in the U S A 2M Z22112 Rev 02 2017 Specifications are subject to change without notice LANG MANUFACTURING www langworld com 10 Sunnen Drive Saint Louis Missouri 63143 Telephone 314 678 6315 Fax 314 7...

Reviews: