IMPORTANT READ 

FIRST IMPORTANT 

 

CAUTION 

THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER 
SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE 
MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR 
PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO 
THE PLACE OF INSTALLATION.

 

 

CAUTION 

ANY STAND, COUNTER OR OTHER DEVICE ON WHICH THE UNIT WILL 
BE LOCATED MUST BE DESIGNED TO SUPPORT THE WEIGHT OF THE 
UNIT.

 

 

CAUTION 

SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN 
CUT.

 

 

DANGER 

THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.  
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN 
ELECTROCUTION AND DEATH. 

WARNING 

INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL 
QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING.  IMPROPER 
INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE 
TO EQUIPMENT.  UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL 
APPLICABLE CODES. 

 

NOTICE 

The data plate is located on the left side of unit behind the control door. 
The unit voltage, wattage, gas specifications, serial number, and 
clearance specifications are on the data plate.  This information should be 
carefully read and understood before proceeding with the installation.  

 

NOTICE 

The installation of any components such as a vent hood, grease 
extractors, fire extinguisher systems, must conform to their applicable 
National, State and locally recognized installation standards. 

 

NOTICE 

Do not install the Cheesemelter over a Charbroiler or any other open 
flame appliance. 

 

NOTICE 

During the first few hours of operation you may notice a small amount of 
smoke coming from the unit, and a faint odor from the smoke.  This is 
normal for a new unit and will disappear after the first few hours of use. 

 

CAUTION 

ALWAYS KEEP THE AREA NEAR THE APPLIANCE FREE FROM 
COMBUSTIBLE MATERIALS.

 

 

CAUTION 

KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN AND DRY.  IF SPILLS 
OCCUR, CLEAN IMMEDIATELY, TO AVOID THE DANGER OF SLIPS OR 
FALLS. 

 

WARNING 

KEEP WATER AND SOLUTIONS OUT OF CONTROLS.  NEVER SPRAY OR 
HOSE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC. 

 

CAUTION 

MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS 
MEMBRANES AND CLOTHING.  PRECAUTIONS SHOULD BE TAKEN TO 
WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND 
PROTECTIVE CLOTHING.  CAREFULLY READ THE WARNING AND 
FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE 
USED

.

 

 

Summary of Contents for 236CM

Page 1: ...cturing 10 Sunnen Drive St Louis MO 63143 Part 2M 60803 02 Phone 314 678 6315 Fax 314 781 2714 Rev C www langworld com July 22 2008 Installation Operation Maintenance Model 236CM 248CM Gas Infrared Ch...

Page 2: ...D MAY RESULT IN MINOR OR MODERATE INJURY NOTICE Helpful operation and installation instructions and tips are present FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS...

Page 3: ...FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL TABLE OF CONTENTS CHAPTER PAGE TABLE OF CONTENTS 3 READ FIRST 4 SAFETY PROCEDURES 6 EQUIPMENT DESCRIPTION 7 UNPACKING 8 INSTALLATION 9 INI...

Page 4: ...fications are on the data plate This information should be carefully read and understood before proceeding with the installation NOTICE The installation of any components such as a vent hood grease ex...

Page 5: ...G service agent nearest you WARNING BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED WIRED INTO A LIVE RECEPTACLE BEFORE CLEANING SERVICING OR REPLACING ANY PARTS...

Page 6: ...ntrol and interlocks on an appliance and attendant components of installation cannot in and of themselves assure absolute safety of operation Diligent capable well trained operators and maintenance pe...

Page 7: ...ation for efficiency and reduced heat loss Interior The interior dimensions are 10 25 4cm High 14 36 8cm deep and 33 45 83 8cm 114 3cm Wide The melter comes standard with one rack which can be placed...

Page 8: ...the carrier s agent Concealed loss or damage means loss or damage which does not become apparent until the merchandise has been unpacked If concealed loss or damage is discovered upon unpacking make a...

Page 9: ...e legs so that burners are level Leg adjustment is made by turning the adjustable foot at the bottom of each leg Ensure that the leg does not turn while adjusting the foot WALL HUNG INSTALLATIONS The...

Page 10: ...off valve must be installed to the appliance and located in an accessible area In the event of a significant drop in gas pressure turn the shut off valve off and contact your gas supplier This applian...

Page 11: ...at the pilot burner as air must first be purged from the gas line The pilot burner will remain lit even if the Cheese Melter is switched to Off Once the pilot burner is lit allow one minute for pilot...

Page 12: ...e used for quick browning and toasting with the heat decreasing at each lower position In order to change positions simply slide the rack in and out of the slots provided Make sure that the end of the...

Page 13: ...ssible use Constant during peak periods DON TS Do not use the melter as a cooking or baking device it is best suited for finishing dishes immediately prior to serving Do not use the unit to heat or th...

Page 14: ...t tint may be removed using a Carbon Release oven cleaner The oven interior should be cleaned using a mild soap and a non metal scouring pad DO NOT use caustic cleaners Always apply these cleaners whe...

Page 15: ...ise to lengthen the pilot flame The pilot must light the main burner within 5 seconds of gas being available at the burner tiles listen for the solenoid valve to open The pilot must light the main bur...

Page 16: ...ilot valve Burner will not light Auto Constant switch in incorrect position Defective regulator Plugged main orifice Incorrect water column Defective solenoid valve Low pilot No gas to unit Defective...

Page 17: ...ch Check switch for normal operation Defective Power Cord Check Power cord for continuity Defective Regulator Check unit for proper Water Column Plugged Orifice Clean orifice Faulty Solenoid Valve Che...

Page 18: ...ifold Gas Melter 3ft 4ft 5ft Units 2K 80100 10 Manifold Gas Melter 4ft 5ft Units 2K 80100 11 Pilot Burner Assembly 2J 80201 20 Orifice Pilot Burner 010 DRL LP 2A 80401 09 Orifice Pilot Burner 021 DRL...

Page 19: ......

Page 20: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Reviews: