16
JUMPER
GRIDDLE ELEMENTS
1
2
3
4
5
GRIDDLE PILOT LAMP
GRIDDLE THERMOSTAT
TERMINAL BLOCK
L2
5
L3
L1
4
*
18
26
25
CONN #2 USE LG36
DLG
2
2
3
4
10
17
2
3
12-13-02
LG72: CONN #1 USE LG36
5
2
3
4
5
2
3
4
5
1
1
1
16
15
23
*
31
LG48
LG36
LG24
22
32
8
7
6
5
29
30
22
*
14
21
13
4
3
27
28
20
*
12
19
11
5
1
NOTES:
LG60 & LG72 HAVE TWO POWER SUPPLY CONNECTIONS
LG60: CONN #1 USE LG36
CONN #2 USE LG24
1
9
11
A
B
C
D
DWG. NO:
SHEET
OF
DWN. DATE :
DWN. BY :
CHK. BY :
DESCRIPTION:
LANG GRIDDLE 208-240/220VAC
1
Company
Manufacturing
61114-01
REV:
1
G
1
CAD FILE :
FROM ACAD
CHK. DATE :
REV. BY :
REV. DATE :
E
F
G
H
H
G
F
E
D
C
B
A
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
12
2 POLE THERMOSTAT.
9
17
10
*
18
26
25
1
2
2
1
5
4
3
NOTE: TYPICAL WIRING FOR EACH
SECTION ON UNITS THAT HAVE A
TYPICAL
208-220 V
240V
INSTALL
REMOVE
JUMPER
JUMPER
ELEMENT HOOKUP
(ITEM 4)
(ITEM 4)
AMPS 1
L1-L2
L2-L3
L1-L3
TOTAL
L1
L2
L3
PHASE L1
L2
L3
L1
L2
208
6.0
6.0
12.0
50.0
28.9
28.9
57.7
220
6.7
6.7
13.4
52.9
30.5
30.5
60.9
240
6.0
6.0
12.0
43.3
25.0
25.0
50
208
6.0
6.0
6.0
18.0
50.0
50.0
50.0
86.5
220
6.7
6.7
6.7
20.1
52.9
52.9
52.9
91.4
240
6.0
6.0
6.0
18.0
43.3
43.3
43.3
75
208
12.0
6.0
6.0
24.0
76.0
76.3
50.0
115.4
220
13.4
6.7
6.7
26.8
80.6
80.6
52.9
121.8
240
12.0
6.0
6.0
24.0
66.1
66.1
43.3
100
3,6
1,3,5,7
1,3,5
2,4,6
2,4,6,8
2,4
1,4
2,5
3,6
LG48
LG36
1,4
2
1,4,7
2,5,8
MODEL
LG24
Kw
SERVICE CONNECTIONS
AMP TOTALS
VOLT
THREE PHASE
SINGLE PHASE
3
1,3
Revision Block
REV
ECN NO.
DESCRIPTION
DR.
MFG.
ENG.
DATE
E
REVISED AND REDRAWN
CDS
10/15/2002
F
ADDED 220VAC FOR LGCL
DLG
12/13/2002
G
6170
ADDED WIRING FOR 2 POLE
TSTAT
DJS