background image

LA65D

IMPORTANT SAFETY INSTRUCTIONS

Page

2 / 20

WARNING:

 When using electrical products, basic cautions should always be followed, including the following:

1. 

Read these instructions. 

2. 

Keep these instructions safe.

3. 

Heed all warnings.

4. 

Follow all instructions.

5. 

Do not use this apparatus near water. 

6. 

Clean only with a dry cloth.

7. 

Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 

8. 

Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including  amplifiers) that produce heat.

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider 

than the other. A grounding type plug has two blades and a third grounding plug. The wide blade or third prong is provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10. 

Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit from the apparatus.

11. 

Only use attachments/accessories provided by the manufacturer.

12. 

Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when 

moving the cart/apparatus combination to avoid injury from tip-over.

13

Unplug this apparatus during lightning storms 

or when unused for long periods of time.

14. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when power-supply 

cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not 
operate normally, or has been dropped.

15. 

Never break off the ground pin. Connect only to a power supply of the type marked on the unit adjacent to the power supply cord.

16. 

If this product is to be mounted in an equipment rack, rear support should be provided.

17. 

Note for UK only: If the colours of the wires in the mains lead of this unit do not correspond with the terminals in your plug‚ proceed as follows:

     a) The wire that is coloured green and yellow must be connected to the terminal that is marked by the letter E‚ the earth  symbol‚ coloured green or
         coloured green and yellow.
     b) The wire that is coloured blue must be connected to the terminal that is marked with the letter N or the colour black.
     c) The wire that is coloured brown must be connected to the terminal that is marked with the letter L or the colour red.

18.

This electrical apparatus should not be exposed to dripping or splashing and care should be taken not to place 

objects containing liquids, such as vases, upon the apparatus.

19. 

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably in 

susceptibility to noise-induced hearing loss, but nearly everyone will lose some hearing if exposed to sufficiently 
intense noise for a sufficient time.
    The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the following 
permissible noise level exposures: According to OSHA, any exposure in excess of the above permissible limits could 
result in some hearing loss. Earplugs or protectors to the ear canals or over the ears must be worn when operating 
thisamplification system in order to prevent a permanent hearing loss, if exposure is in excess of the limits as set 
forth above. To ensure against potentially dangerous exposure to high sound pressure levels, it is recommended that 
all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system 
be protected by hearing protectors while this unit is in operation.

An apparatus with Class I construction shall be connected to a mains socket outlet with a protective connection. Do not defeat the safety purpose of the 

polarized or grounding-type plug.

The mains plug or appliance coupler is used as the disconnect device and shall remain readily operable.

 

The user should allow easy access to any 

mains plug, mains coupler and mains switch used in conjunction with this unit thus making it readily operable. 

Duration Per Day

In Hours

8
6
4
3
2

1 ½

1

½

¼ or less

Sound Level dBA, 

slow response

90
92
95
97

100
102
105
110
115

Summary of Contents for LA65D

Page 1: ...OPERATING INSTRUCTIONS 1 2 ...

Page 2: ... the wires in the mains lead of this unit do not correspond with the terminals in your plug proceed as follows a The wire that is coloured green and yellow must be connected to the terminal that is marked by the letter E the earth symbol coloured green or coloured green and yellow b The wire that is coloured blue must be connected to the terminal that is marked with the letter N or the colour blac...

Page 3: ...e ci doit être contrôlée si elle a subit des dommages de manipulation d utilisation ou de stockage humidité 15 Ne déconnectez jamais la prise de terre de votre unité 16 Si votre unité est destinée a etre montée en rack des supports arriere doivent etre utilises 17 Note pour les Royaumes Unis Si les couleurs de connecteurs du cable d alimentation ne correspond pas au guide de la prise secteur procé...

Page 4: ...iensttechnikern durchführen Eine Wartung ist erforderlich wenn das Gerät in irgendeiner Art beschädigt wurde etwa wenn das Netzkabel oder der Netzstecker beschädigt wurden Flüssigkeit oder Gegenstände in das Gerät gelangt sind das Gerät Regen oder Feuchtigkeit ausgesetzt wurde nicht normal rbeitet oder heruntergefallen ist 15 Der Erdungsstift darf nie entfernt werden Schließen Sie nur an die Strom...

Page 5: ...to ha caído dentro del aparato el aparato ha sido expuesto a la lluvia o la humedad no funciona de manera normal o ha sufrido una caída 15 Nunca retire la patilla de Tierra Conecte el aparato sólo a una fuente de alimentación del tipo marcado al lado del cable de alimentación 16 Si este producto va a ser enracado con más equipo use algún tipo de apoyo trasero 17 Nota para el Reino Unido solamente ...

Page 6: ...auses warnen die von Ausrichender Starke sind um einen elektrischen Schlag verursachen zu konnen Intended to alert the user of the presence of important operating and maintenance Servicing instructions in the literature accompanying the product Dieses Symbol soll den Anwender vor unsolierten gefahrlichen Spannungen innerhalb des Gehauses warnen die von Ausrichender Starke sind um einen elektrische...

Page 7: ...0 15 3 4 515 20 1 4 346 13 3 4 H W D Unit Weight 100W Output Power Rating 65W Digital Chorus with Adjustable Rate Depth Digital 10K Input impedance Input sensitivity 600mV Nom Channel 1 Mic Aux In XLR 6 3 Jack Combo Socket Mic XLR i p sensitivity 3 5mV Nom Mic I P Impedance 1K 15V Phantom Power on Mic XLR Aux In Jack i p sensitivity 200mV Nom Aux I P Impedance 47K Separate LO 12dBu 50Hz shelving H...

Page 8: ...st began building valve amplifiers in my parent s garage Since then we have moved on from strength to strength developing an extensive range of guitar bass public address and keyboard amplification products along with a list of Laney endorsees that includes some of the world s most famous and respected musicians At the same time we believe we have not lost sight of the reason Laney was founded in ...

Page 9: ... to an external FX Controller for processing or via the DI Out to a mixing desk etc Its 65 watt power section drives a pair of Custom Designed 8 Drivers with co axial tweeters optimized especially for acoustic performers A detailed description to allow easy use of all the controls follows The LA65D benefits from our distinctive cosmetic treatment kickback styling Chocolate Brown fascia added to th...

Page 10: ...vent the guitar from overloading the preamplifier PRESHAPE GAIN Controls the gain level of Channel 2 EQ The four band graphic equalizer allows you to easily modify your tone and effectively see the response you are getting There are four sliders covering Low Low Mid High Mid High in the 80Hz 3KHz range When the slider is in the central position the signal at that frequency is unaffected or flat Mo...

Page 11: ...plified signal removing the problem of destructive interference However sometimes the low frequencies being in phase can cause acoustic feed back problems to avoid this try operating the phase reversal switch Most times this will cure the problem One thing to point out is that the audience does not hear any phase problems as by the time the sound wave reaches them any phase differences have been c...

Page 12: ...same size and rating is installed and it in turn blows the amplifier has suffered a malfunction internally and needs immediate service from a qualified technician DO NOT TRY USING A FUSE OF HIGHER RATING Using a fuse that is too large in current rating may cause serious irreparable damage to the amplifier and presents a serious fire hazard The mains fuse ratings are detailed in the specs section o...

Page 13: ...itar output whereas rack mount FX are designed for the higher signal level obtained from an FX send This socket can also be used as a Line Level Out BY PASS LEVEL SWITCH This switch allows the effects loop to be by passed if not in use it also gives you the option of running the FX loop at 0dB 750mV or at 10dB 250mV to suit your processor EFFECTS LOOP RETURN Connect the output from your external e...

Page 14: ...won t do your gear justice Employez cette caractéristique de conception avec prudence en raison de la facilité avec laquelle l amplificateur peut être déplacé entre directement et des positions de contrecoup seulement utilisation l amplificateur sur une surface de niveau et stable N actionnez pas l amplificateur sur un bureau une table une étagère ou une plate forme nonstable autrement peu convena...

Page 15: ...g European Regulations Directives Rules CE Mark 93 68 EEC Low Voltage 72 23 EEC EMC 2004 108 EEC RoHS EU2002 95 EC WEEE EU2002 96 EC BLOCK DIAGRAM D I OUT PAD ON OFF HEADPHONE SOCKET GAIN GAIN GRAPHIC EQUALISER LO LM HM HI INSTRUMENT XLR 6 3 JACK COMBO MIC AUX IN XLR 6 3 JACK COMBO ON OFF RATE DEPTH ANTI FEEDBACK ON OFF DIGITAL REVERB LEVEL FREQUENCY FX RETURN LINE OUT FX SEND BYPASS 0 dB 10dB GRO...

Page 16: ... 1 9 3 10 4 6 0 5 8 2 MIC AUX IN GAIN 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 8 2 PAD LO HM LM HI EQUALISATION 500 25 125 ANTI FEEDBACK SHIMMER 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 8 2 CHORUS RATE DEPTH CHANNEL 1 CHANNEL 2 VOLUME 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 8 2 PRESHAPE PEAK PHASE ON ON CD MP3 Player Guitar Mic 2nd Guitar Keyboard ...

Page 17: ...LINE OUT FX RETURN 10dBu GND LINK PHONES 0 SERIAL NO DESIGNED AND ENGINEERED IN THE UK N15039 Power To The Music WWW LANEY CO UK L Z B1 2 3 4 Page 17 20 Mixer Desk Headphones Footswitch Input Output FX Controller LA65D or straight Combo MAXIMUM POWER CONSUMPTION 100 WATTS 50 60Hz SUPPLY VOLTAGE FUSE RATING ...

Page 18: ...2 7 1 9 3 10 4 6 0 5 8 7 1 9 3 10 4 6 0 5 8 7 1 9 3 10 4 6 0 5 8 7 1 9 3 10 4 6 0 5 8 2 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF GAIN LO HI REVERB REVERB 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 8 2 INSTRUMENT LA65D ACOUSTIC AUX IN MIC AUX IN GAIN PAD LO HM LM HI EQUALISATION 500 25 125 ANTI FEEDBACK SHIMMER 7 1 9 3 10 4 6 0 5 8 2 7 1 9 3 10 4 6 0 5 ...

Page 19: ...NOTES Page 19 20 LA65D ...

Page 20: ...In the interest of continued product development Laney reserves the right to amend product specification without prior notification w w w l a n e y c o u k LA N E Y AM P L I F I C A T I O N ...

Reviews: