Table 13.
Interface set-up – alarm severity level values, switch-on and switch-off threshold
values.
Parameter name
Allowed status
Default
value
Description
ES/SES threshold
exceeding alarm
Urgent alarm
Non-urgent alarm
None
Urgent alarm
for SES
counters
Non-urgent
alarm for ES
counters
ES/SES threshold exceeding alarm
activity
Threshold value of
switching on an urgent
alarm after SES was
exceeded in a 15-minute
period
0..900 15
Value for SES in a 15-minute period,
above which an urgent alarm is
switched on
Threshold value of
switching off an urgent
alarm after SES was
exceeded in a 15-minute
period
0..900 0
Value for SES in a 15-minute period,
below which an urgent alarm is
switched off.
Threshold value of
switching on an urgent
alarm after SES was
exceeded in a 24-hour
period.
0..86400 1440
Value for SES in a 24-hour period,
above which an urgent alarm is
switched on
Threshold value of
switching off an urgent
alarm after SES was
exceeded in a 24-hour
period
0..86400 0
Value for SES in a 24-hour period,
below which an urgent alarm is
switched off
Threshold value of
switching on a non-
urgent alarm after ES
was exceeded in a 15-
minute period
0..900 120
Value for ES in a 15-minute period,
above which a non-urgent alarm is
switched on
Threshold value of
switching off a non-
urgent alarm after ES
was exceeded in a 15-
minute period.
0..900 0
Value for ES in a 15-minute period,
below which a non-urgent alarm is
switched off.
Threshold value of
switching on a non-
urgent alarm after ES
was exceeded in a 24-
hour period
0..86400 11520
Value for ES in a 24-hour period,
above which a non-urgent alarm is
switched on
Threshold value of
switching off a non-
urgent alarm after SES
was exceeded in a 24-
hour period
0..86400 0
Value for ES in a 24-hour period,
below which a non-urgent alarm is
switched off
5.5.2.3 15-minute and 24-hour registers
These panels allow the operator to monitor ES, SES, SESFE, BBE and UAS counter
values in 15-minute and 24-hour periods, respectively. The "alarm" columns show the type of