5.3 Installation and start-up
In order to start up the supervision software, VT100 terminal or a VT100 terminal
emulation program should be correctly set up.
The tables below show examples of
TERM95
and
HYPERTERMINAL
setup. If another
program is used, the user should set the appropriate parameters based on the user manual
of the program:
Transmission speed
9600
Data bits
8
Parity
none
Stop bits
1
Flow control
none
Emulation VT100
Table 10.
VT100 terminal settings for "TERM95" program
TERM95
Speed 9600
number of data bits
8
number of stop bits
1
flow control
none
local echo
none
terminal type
VT100
Table 11.
VT100 terminal settings for "HYPER TERMINAL" program
HYPERTERMINAL
bits per second
9600
Data bits
8
Parity none
Stop bits
1
flow control
none
Font terminal
local echo of entered characters
none
5.4 Beginning the terminal operation
After the device is started up and RS-232 interfaces are connected, enter the
START
command
and press the
ENTER
button.
The command may be entered in small or capital letters.
When the command is identified, TM-77 opens the first window specifying the device type
and its address. Then the password entry window opens. It allows the user to enter the password
protecting from unauthorized access to the device. If the password is not active, it is sufficient
to press ENTER
.