LW 300 E / LW 450 E
Page A - 18
A
L O C A T I N G T H E U N I T
Installation in closed rooms
For installation in closed rooms, observe the following:
• Install the unit horizontally and level. The floor must be vibration-free and capable of taking the
load of the system weight.
• The compressor room must be clean, dry, dust free and as cool as possible. Avoid direct exposure
to sunlight. If possible, install unit in such a manner that the compressor fan can intake fresh air
from outside. Ensure adequate ventilation and exhaust air opening.
• When locating the compressor in rooms of less than 30 m³ space where natural ventilation is not
ensured or other systems having high radiation are operating in the same room, measures must
be taken to provide artificial ventilation.
• Intake air must be free from noxious gas e.g. smoke, solvent vapours, exhaust fumes etc.
• Observe the specified operating temperature (see "Technical Data")!
Danger
No operation in explosion-hazard areas.
The unit is not approved for operation in areas prone to explosion.
!
Version: 261012-001 E