Page A - 39
A
LW 225 E / LW 245 B
Version: 19.11.2015
R E M E D Y I N G F A U L T S
Compressor overheated
Cause of fault
Remedy
Inlet filter cartridge contaminated
Replace
Ambient temperature too high
Improve room ventilation /
Reduce operation times
Cooling air inlet and outlet insufficient
Observe minimum distances (see Installation
Instructions)
Air intake hose too long
Reduce length of the air intake hose
Air intake hose diameter too small
Use a larger diameter
Wrong compressor rotation direction
Ensure correct phase rotation,
observe rotation direction arrow!
Inlet and outlet valves contaminated / defective
Clean, replace if necessary
Safety valve leaks
Cause of fault
Remedy
Inlet and outlet valves of the following pressure
stage defective
Clean, replace if necessary
Sinter filter of the following water separator
blocked
Replace
Safety valve leaky
Replace
Oil taste in the air
Cause of fault
Remedy
Mole carbon filter cartridge saturated
Replace
Compressor oil unsuitable
Use prescribed oil quality
Filter cartridge unsuitable
Use prescribed filter type
Cylinder(s), piston(s) or piston ring(s) defective
Replace
Summary of Contents for LW 225 E
Page 3: ...A Operating Instructions Breathing Air Compressor LW 225 E LW 245 B Version 02 14 E ...
Page 15: ...A S A F E T Y P R E C A U T I O N S ...
Page 22: ...A I N S TA L L AT I O N ...
Page 31: ...A O P E R AT I O N ...
Page 39: ...A R E M E D Y I N G FA U LT S ...
Page 44: ...A M A I N T E N A N C E A N D S E R V I C E ...
Page 73: ...A M A I N T E N A N C E R E C O R D S ...
Page 82: ...B ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS ...
Page 111: ...C O P T I O N S Version 11 12 D ...
Page 113: ...C A U T O S H U T D O W N D 2 LW 225 E 245 B ...
Page 116: ...C A U T O M A T I C C O N D E N S AT I O N D R A I N D 5 LW 225 E 245 B ...
Page 118: ...C S W I T C H O V E R D E V I C E 2 0 0 3 0 0 B A R D 7 LW 225 E 245 B ...
Page 121: ...C A D D I T I O N A L F I L L I N G H O S E D 10 LW 225 E 245 B ...