Recommended fuses for 360 - 500 V operating voltage
Nominal motor power
Fusing start A
Connection in mm²
[kw]
[A]
Direct
Star/Delta
Contactor supply S/D* to Motor
4
8,5
20
16
2,5
1,5
5,5
11,3
25
20
2,5
1,5
Electrical Installation LW 225 E
The compressor comes fully wired with cable and plug. An installation is not necessary.
Recommended fuses for 220 - 240 V operating voltage
Nominal motor power
Fusing start A
Connection in mm²
[kw]
[A]
Direct
Star/Delta
Contactor supply S/D* to Motor
4
14,8
25
20
2,5
1,5
5,5
19,6
35
25
4
2,5
* S/D - Star / Delta.