REMOTE CONTROL COMMAND PROTOCOL
31 / 32
Key Variable
Key Code
Description
0x27
Increase the data of a selected item on the main MEMU .
0x28
Decrease the data of a selected item on the main MENU .
0x32
Switch the power of the Camera ( ON / OFF ) .
KN_R_FAR
0x38
In the manual focus mode , move the Focus lens to “ FAR “ side
slowly . In case of displaying the MENU, operate as the “ Increase
the data of selected item in MENU “.
KN_R_NEAR
0x39
In the manual focus mode , move the Focus lens to “ WIDE “ side
slowly . In case of displaying the MENU, operate as the “ Decrease
the data of selected item in MENU “.
KN_AM_P
0x3F
According to Key selection mode , operate the key such as
“ AUTO / MANUAL Toggle“ or “ Push AUTO “ .
KN_RS_SSCup
0x40
Use for RS-232C Serial Communication :
Scroll up the “ Shutter Speed “ . In case of displaying MENU ,
The AE mode must be “ Shutter Adjust “ , or “ Manual mode “ .
KN_RS_SSCdn
0x41
Use for RS-232C Serial Communication :
Scroll down the “ Shutter Speed “.In case of displaying MENU ,
The AE mode must be “ Shutter Adjust “ , or “ Manual mode “ .
KN_RS_IRISup
0x42
Use for RS-232C Serial Communication :
Scroll up the Iris level of lens . In case of displaying MENU ,
The AE mode must be “ Iris Adjust “ , or “ Manual mode “ .
KN_RS_IRISdn
0x43
Use for RS-232C Serial Communication :
Scroll down the Iris level of lens . In case of displaying MENU ,
The AE mode must be “ Iris Adjust “ , or “ Manual mode “ .
KN_RS_AGCup
0x44
Use for RS-232C Serial Communication :
Scroll up the AGC level . In case of displaying MENU , The AE
mode must be “ AGC Adjust “ , or “ Manual mode “ .
KN_RS_AGCdn
0x45
Use for RS-232C Serial Communication :
Scroll down the AGC level . In case of displaying MENU , The AE
mode must be “ AGC Adjust “ , or “ Manual mode “ .
KN_RS_BRTup
0x46
Use for RS-232C Serial Communication :
Scroll up the Brightness level .
KN_RS_BRTdn
0x47
Use for RS-232C Serial Communication :
Scroll down the Brightness level .
KN_M_UP
KN_M_DN
KN_POWER