D
Version: 25.09.2013
Auto Start Function
The auto start function allows operating the compressor
optionally in automatic or semi-automatic mode by turning
the selector switch.
Semi-automatic operation:
Start the compressor by pushing the Start button. The
compressor automatically shuts off when final pressure is
reached. To restart the compressor, push the Start button
again. The unit can be shut down at any time during
operation by pushing the Stop button.
Automatic operation:
Start the compressor only once by pushing the Start button. The Start button lights up and the unit
automatically shuts off when final pressure is reached. If outlet pressure decreases below the
selected minimum pressure, the unit automatically restarts.
To enable a manual start, shut off automatic operation by pushing the Stop button (Start button
lamp goes out). Now turn selector switch to semi-automatic mode and start the compressor with
the Stop button.
Adjust start pressure (minimum pressure)
The pressure switch for start pressure is located after the
pressure maintaining valve. The pressure can be adjusted
with the upper adjusting screw.
Increasing start pressure: turn adjusting screw clockwise
Reducing start pressure: turn adjusting screw anti-clockwise
Adjust pressure switch in steps of a quarter turn. Check
settings after every adjustment step.
A U T O S T A R T F U N C T I O N
Note
The compressor can not be manually started during automatic operation.
i
Selector switch auto start function
Adjust start pressure
D - 3
LW 230 - 280 - 320 ES
Summary of Contents for LW 230 ES
Page 12: ...A S A F E T Y P R E C A U T I O N S ...
Page 19: ...A I N S TA L L AT I O N ...
Page 26: ...A O P E R AT I O N ...
Page 34: ...A R E M E D Y I N G FA U LT S ...
Page 39: ...A M A I N T E N A N C E A N D S E R V I C E ...
Page 68: ...A M A I N T E N A N C E R E C O R D S ...
Page 76: ...B Operating Instructions ECC Electronic compressor control www uebler net Version 11 12 E ...
Page 96: ...C ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS ...
Page 158: ...D O P T I O N S ...
Page 160: ...D A U T O S T A R T F U N C T I O N D 2 LW 230 280 320 ES ...
Page 165: ...D O I L P R E S S U R E G A U G E D 7 LW 230 280 320 ES ...
Page 168: ...D O I L P R E S S U R E M O N I T O R I N G D 10 LW 230 280 320 ES ...
Page 172: ...D O I L T E M P E R A T U R E M O N I T O R I N G D 14 LW 230 280 320 ES ...
Page 175: ...D I N T E R S TA G E P R E S S U R E G A U G E D 17 LW 230 280 320 ES ...
Page 179: ...D C Y L I N D E R H E A D T E M P E R AT U R E M O N I T O R I N G D 21 LW 230 280 320 ES ...
Page 186: ...D A I R C O O L E R C O N N E C T I O N K I T D 28 LW 230 280 320 ES ...
Page 189: ...D C O N D E N S A T E TA N K 6 0 LT R D 31 LW 230 280 320 ES ...