Page A - 39
A
LW 100 Series
Version: 29.03.2016
R E M E D Y I N G F A U L T S
Filter life not sufficient
Cause of fault
Remedy
Pressure maintaining valve settings not correct
Adjust as prescribed
Filter cartridge unsuitable
Replace by a prescribed filter cartridge type
Filter cartridge too old
Observe expiration date
Filter cartridge packaging incorrect / damaged /
already opened. Filter cartridge already partly
saturated before change
Store filter cartridges properly, dispose defective
cartridges
Cylinder(s), piston(s) or piston ring(s) defective
Replace
Operating temperature too high
Ensure sufficient ventilation
Oil consumption too high
Cause of fault
Remedy
Cylinder(s), piston(s) or piston ring(s) defective
Replace
Compressor oil unsuitable
Use prescribed oil quality
Operating temperature too high
Observe prescribed operating temperatures
Oil leak at the compressor block
Tighten corresponding mounting screws, if
necessary replace corresponding paper sealing /
o-ring / shaft seal
Summary of Contents for LW 100 B
Page 3: ...A Operating Instructions Breathing Air Compressor LW 100 series Version 29 03 2016 ...
Page 14: ...A S A F E T Y P R E C A U T I O N S ...
Page 21: ...A I N S TA L L AT I O N ...
Page 29: ...A O P E R AT I O N ...
Page 37: ...A R E M E D Y I N G FA U LT S ...
Page 42: ...A M A I N T E N A N C E A N D S E R V I C E ...
Page 68: ...A M A I N T E N A N C E R E C O R D S ...
Page 77: ...B ERSATZTEILLISTEN SPARE PARTS LISTS DETAILANSICHTEN DETAILED VIEWS ...
Page 118: ...C O P T I O N S Version 11 12 D ...
Page 120: ...C A D D I T I O N A L F I L L I N G H O S E C 2 LW 100 Series ...
Page 122: ...C S W I T C H O V E R D E V I C E 2 0 0 3 0 0 B A R C 4 LW 100 Series ...
Page 126: ...C A U T O M A T I C C O N D E N S AT I O N D R A I N C 8 LW 100 Series ...
Page 130: ...C A U T O S H U T D O W N C 12 LW 100 Series ...
Page 135: ...C S P E C I A L M O T O R S C 17 LW 100 Series ...
Page 144: ...C S P E C I A L V O LTA G E C 26 LW 100 Series ...