7K458-0221
3-3
Seed Rate Adjustment -
Adjusting the Box Slide
When properly adjusted, with the control handle set at “6”.
The holes in the slide should line up with the holes in the
box.
To make an adjustment, loosen the
control handle on the box, move the slide until the holes
line up. When the handle is moved to “0” the holes in the
box should be completely covered.
If the holes are not covered, loosen the three bolts holding
the seed meter casting and shift it slightly so that the “0”
mark is farther from the control handle. Retighten the
bolts. Move control handle to “0”. Holes in the box should
then be completely covered.
Figure 3-3: Control Handle at “6”
Figure 3-4: Control Handle at “0”
Figure 3-5: Seed meter Casting Bolts
If the holes are not covered
when set at 0, loosen these
three bolts holding the
seedmeter casting and shift
it slightly. Retigthen the bolts.