7
25 GND
Ground
26 GND
Ground
27
RxEC-
Negative LVDS differential clock, (Even clock)
28
RxEC+
Positive LVDS differential clock, (Even clock)
29
RxE3-
Negative LVDS differential data, CH3 (Even data)
30
RxE3+
Positive LVDS differential data, CH3 (Even data)
6. OSD
The OSD board and its push buttons are shown in the following figure:
Power
Menu
-
+
Down
Up
LED
There are six push buttons on the OSD board. The functions of the buttons are summarized below:
POWER
Turns the LCD power on and off.
MENU
Brings up the OSD menu and activate the selected item to enter the next Menu.
UP & DOWN Moves through various adjustments in each OSD Menu. Also after the selected
adjustment is activated, use Up & Down buttons to increase & decrease the
setting.
+
Hot key to active the AUTO SETUP function in the OSD Main Menu.
-
Reserved for future use. For the current Version A, this button has no function.
The POWER button
When the POWER button is pushed on, the LED turns to green and the LCD screen is turned on.
Push the POWER button off turns off the LED and the video connection. If the inverter On/Off
control is connected to Pin #3 of CN8, then the inverter/backlight will be turned off.
The OSD Menu
When the MENU button on the OSD board is pressed, the Main Menu appears on the screen: