![Landis+Gyr FOCUS kWh Technical Manual Download Page 22](http://html1.mh-extra.com/html/landis-gyr/focus-kwh/focus-kwh_technical-manual_673719022.webp)
5.
Overview of Electronic Hardware
Delete “Optical” below
5.1.1.
LCD Display
Figure 18 – Liquid Crystal Display
The
kWh FOCUS
LCD shows the digital power indicator, nominal service voltage and various
selectable metrics.
5.1.2.
Display Scroll Sequence:
The display scroll sequence is programmable at the factory or by the user with
Focus Configuration
Tool
. The scroll sequence can consist of up to 16 individual displays. The display choices are:
•
+kWh
•
-kWh
•
NET kWh
•
ADDED kWh (Security)
•
Segment Check with Active DPI
•
Line Voltage(s)
Duplicate display choices are permitted as long as the total number of display choices in the scroll
sequence does not exceed 16.
The time of display can be programmed from 1 to 15 seconds in one-second increments.
When internal meter errors occur, error codes will be added to the end of the scroll sequence.
13
13