Operation
© Gyr
D000029326 en g – E450 PLC 1-phase ZCX100Px – User Manual
In the event of a critical error, the operating display is interrupted and the
F.F register with an error is shown on the display along with the blinking
alarm symbol. The F.F register is displayed as long as no key (display or
reset) is pressed. After pressing the key or clearing the error register, the
meter goes into the operating display mode and it continuous in normal
operation.
5.2.2
Display Menu
The display menu contains the standard display list under the
Std_dAtA
menu and the MID data is listed under the
MId_dAtA
menu item.
The different menu items can be obtained by briefly pressing the display
key.
Fig. 5.3 Display menu
With the
Std_dAtA
menu a pre-configured list of all important metering
data can be shown on the display.
To enter the standard display list, scroll
to the menu item
Std_dAtA
and press the display key for > 2 seconds and
release it, then the first value in the display list appears.
Within the display list the following navigation is available:
•
Briefly pressing the display key navigates form value to value.
•
A long press of the display key (> 2 seconds) skips the previous stored
values or "demands" i.e. the next main value will be shown.
•
If the display key is held down for more than 10 seconds, the display
scrolls through the main values at one second intervals (rapid trav-
erse).
Errors
Standard Display List