6.15. Volatile Meter State – Upper (Register 036)
The meter displays the most significant eight bits of the
volatile meter state register
. This
register indicates the current state of the following meter functions:
Volatile Meter State Register – Upper
Display Function
1
xxx xxxx
Not Used
x
1
xx xxxx
Not used
xx
1
x xxxx
Not used
Xxx
1
xxxx
Not used
Press ‘036’ to toggle between UPPER set and LOWER sets of 4 numbers
xxxx
1
xxx
Production Engineering Mode Enable
xxxx x
1
xx Not
used
xxxx xx
1
x
Reason for latch hold-back: Overload / Magnetic trip
xxxx xxx
1
Phase direction indicator
6.16. Volatile Meter State – Lower (Register 037)
The meter displays the least significant eight bits of the
volatile meter state register
. This
register indicates the current state of the following meter functions:
Meter State Register – lower
Display Function
1
xxx xxxx
Meter Creep Lock Condition
x
1
xx xxxx
Not used
xx
1
x xxxx
Not used
Xxx
1
xxxx
Tamper Switch State
Press ‘037’ to toggle between UPPER set and LOWER sets of 4 numbers
xxxx
1
xxx Not
Used
xxxx x
1
xx Not
used
xxxx xx
1
x
DC Magnetic Field Detected
xxxx xxx
1
DC Magnetic Field Trip State