Landis & Gyr Ultrasonic UH50 General Information Manual Download Page 5

UH50 Ultrasound Heatmeter 

 

Configuration Instructions 

UH 106-101c 

Page 5 / 13 

24 V safety extra-low voltage  

Voltage 

12..36 V AC or 12..42 V DC

 

Frequency  

50 / 60 Hz or DC 

Galvanic isolation 

1000 V DC 

Power consumption 

maximal 0.8 VA

 

Terminals 

2 x 1.5 mm² 

For connecting cable 

about, Ø 5.0..6.0 mm

 

110 V or 230 V alternating voltage  

Voltage 85..121 

V AC

 

          or 

196..253 

V AC

 

Type 

Safety class II 

Frequency  

50 / 60 Hz 

Line voltage 

max. 10% of the nom. 

fluctuations voltage 
Overvoltage category 

II 

per EN60010 

2500 V impulse voltage 

Power consumption 

maximal 0.8 VA 

Relative humidity 

less than 93 % for T < 50°C 

Cable length 

1.5 / 5 / 10 m 

Fuse protection 

6 A MCB

 

 

Interfaces of the electronic unit 

The UH50 heat meters are equipped with an optical 
interface per EN 62056-21:2002 as standard. 
Moreover, up to two of the following communication 
modules can be used for remote reading (for 
restrictions, see Page 5): 

 

Pulse module (pulses for quantity of heat / 
volume / unit status / tariff register 1 / tariff 
register 2; isolated, bounce-free) 

 

CL module (passive 20 mA current loop per EN 
62056-21:2002) 

 

M-bus module per EN 1434-3, fixed and 
extended, variable protocol (also for coupling 
with a suitable heating controller) 

 Analog 

module 

 Radio 

module 

 Multi-module 

(external) 

These modules are have no effect on consumption 
metering and can therefore also be replaced at any 
time without violating the adhesive label. 

Terminals 

2-pole and 4-pole terminals are used for connecting 
external cables to the modules. 

Strip-back length: 

5 mm 

Connection capacity 

  rigid or flexible, 0.2 – 2.5 mm² 

  flexible with end ferrules, 0.25 - 1.5 mm² 

  conductor sizes 26 - 14 AWG 

Multiple-conductor connection (2 conductors of 
same cross-section) 

  rigid or flexible, 0.2 – 0.75 mm² 

  flexible with end ferrules without plastic 

sleeve, 0.25 – 0.34 mm² 

  flexible with TWIN ferrules with plastic 

sleeve, 0.5 – 0.75 mm² 

Recommended screwdriver: 0.6 x 3.5 mm 
Tightening torque:  0.4 Nm 

 

Permissible combinations of modules 

Slot for module #2 is equipped 

with...

 

Pulse 

module

 

AM = Analog module
MB = M-bus module
CL = CL module 
RM = Radio module 

AM

 

“st

a

n

d

a

rd

“ 

“f

ast

” *)

 

MB CL RM 

AM

 

yes 

yes 

yes 

yes (4) 

yes 

yes 

“standard” 

yes (3) 

yes (2) 

yes (4) 

yes 

yes 

yes 

Pulse module **)

 

“fast” 

no 

no 

no 

no 

no 

no 

MB

 

yes 

yes 

yes 

yes 

(4) 

yes 

(1) 

yes 

CL

 

yes 

yes 

yes 

yes 

(1) 

no 

yes 

Slot for module  #1 can be equipped with ...

 

RM

 

no 

no 

no 

no 

no 

no 

Restrictions: 
*) only 1 module with fast pulses is possible; 
  only permissible on slot 2; 
  min. pulse duration : 
  - 2 ms, if pulse module 1 not fitted 
  - 5 ms, if pulse module 1 fitted 
**) Subsequent mounting of a further pulse module 
in module slot 1 can result in changed output values 
for module 2! 
 (1)  For M-bus with controller coupling, the CL read-
out can take up to 40 s 
(2)  Pulse length of the fast pulses min. 5 ms 
(3)  The first and second channel can be 
parameterized individually 
(4)  The secondary address for both modules can 
only be changed via module No. 1 

Pulse module 

Pulse module

Pulse output:

Channel 1,
Channel 2 

 

The pulse module permits the output of pulses that 
can be derived from the quantity of heat, the volume, 
tariff register 1 or tariff register 2. Two channels are 
available whose functions can be parameterized 
with the PappaWin software. 
Output takes the form of standard pulses or “fast 
pulses”. The pulse duration is identical for channel 1 
and channel 2. 
Note: If two pulse modules are plugged, please note 
the restrictions! 

Summary of Contents for Ultrasonic UH50

Page 1: ...temperature 20 to 60 C Max height 2000 m above MSL Ambient temperature 5 to 55 C Ambient humidity 93 rel Housing degree of prot IP 54 per EN 60529 Safety class Line 110 230 V AC II per EN 61558 Line 24 V ACDC III per EN 61558 Response threshold f T0 2 K Temperat difference T 3 K to 120 K Temperat meas range 2 180 C Sensors Type Pt500 or Pt100 per EN 60751 Temperature range 0 150 C 45 mm overall le...

Page 2: ...r outlet sections are necessary However if the heat meter is installed in the shared return of two heating systems e g heating and hot water the mounting location must be a sufficient distance from the T element that forms the junction min 10 DN to allow the different water temperatures to mix well The sensor can be mounted in ball valves or in pockets The sensors must be inserted at least up to t...

Page 3: ...d of the loop Accumulated quantity of heat with tariff status Tariff register 1 optional Accumulated volume Segment test Error message with error code number LCD button 1 is used to switch the display from the user loop to the selection of service loops LOOP 1 n Service loop selection Service loop 1 Service loop 2 LOOP n Service loop n LCD button 1 advances the display to the next loop After the l...

Page 4: ...re difference flow temperature and return temperature with their date stamps on a yearly set day Monthly values The electronic unit stores the meter readings for quantity of heat volume the tariff register missing time and flowrate measuring time as well as the monthly maxima for flowrate power temperature difference flow temperature and return temperature with their date stamp for 18 months on th...

Page 5: ... end ferrules 0 25 1 5 mm conductor sizes 26 14 AWG Multiple conductor connection 2 conductors of same cross section rigid or flexible 0 2 0 75 mm flexible with end ferrules without plastic sleeve 0 25 0 34 mm flexible with TWIN ferrules with plastic sleeve 0 5 0 75 mm Recommended screwdriver 0 6 x 3 5 mm Tightening torque 0 4 Nm Permissible combinations of modules Slot for module 2 is equipped wi...

Page 6: ...conducting Pulses for operating states Ready pulsed conducting i e 100 200 µs pulse duration 500 ms period Fault constantly non conducting Fast pulses Note In battery operation a D cell is required For applications such actuating controllers or as flowrate transmitters higher pulse rates are required The parameters required for this pulse significance pulse duration can be configured with the Papp...

Page 7: ...and maximum power measuring period with maxima for power flowrate and temperatures actual values for power flowrate and temperatures F0 pre warning setting and resetting a user lock setting the date and time and the primary and secondary address Special version with minimum update rate of 30 s can be supplied WZU MB 30 but it has a shorter battery life Data scope for fast readout Update after a mi...

Page 8: ...l mode The data are packed and output in various telegram types Data content All telegrams are preceded by the time stamp date and time and the property number Telegram type Content Basic Cumulated values and error status Previous year Cumulated previous year s values and error status Previous month Cumulated previous month s values and error status Extended Current instantaneous values stored max...

Page 9: ...ated or all tariffs can be deactivated Surcharge quantity tariff by means of return temperature tariff T12 The quantity of heat is summated depending on the return temperature in tariff registers 1 or 2 The summated quantity of heat is calculated from the difference of the return temperature from the defined return temperature threshold instead of from the temperature difference Above return thres...

Page 10: ...thly set day parameterized 21 Master reset performed 22 All times deleted 23 Missing time deleted 24 Event occurs Maxima deleted Read out is performed via the optical interface with the PappaWin software Data logger optional The data logger permits the archiving of data that the user can select from a predefined set of values The data logger contains four archives whose 8 channels can be assigned ...

Page 11: ... length 190mm nominal pressure PN16 connection G 1 B 23 Nominal flowrate 1 5 m h length 190mm nominal pressure PN25 connection flanged DN 20 24 Nominal flowrate 1 5 m h length 190mm nominal pressure PN25 connection G 1 B 25 Nominal flowrate 2 5 m h length 130mm nominal pressure PN16 connection G 1 B 36 Nominal flowrate 2 5 m h length 130mm nominal pressure PN25 connection G 1 B 37 Nominal flowrate...

Page 12: ... mounted in the tube F Sensor Pt500 removable mounting in the tube as an option G Sensor Pt500 removable mounted in the tube within a pocket H Sensor Pt100 not removable not mounted in the tube N Sensor Pt100 not removable mounted in the tube P Sensor Pt100 not removable mounting in the tube as an option R Sensor Pt100 not removable mounted in the tube within a pocket S Hardware dependent features...

Page 13: ...supply 24V AC DC with plug WZU ACDC24 00 Communication modules Code Analog module WZU AM CL Module WZU CL M bus module WZU MB M bus module with 30s minimum reading cycle WZU MB 30 M bus module with guaranteed data set WZU MB GR Pulse module WZU P2 Pulse module with OptoMOS WZU P2L Radio module WZU RM Radio module with external antenna WZU RM EXT Notes Regulations on the use of heat meters must be ...

Reviews: