Operating and  
Installation Instruction 

 

Ultrasonic heating and cooling meter 
ULTRAHEAT

®

T230

 

 

 

 

13.06.2017 

Translation 

 

T230 

 

 

Gyr GmbH 

Subject to change without prior notice 

13.06.2017 

 

Note: 

In the following text, the term meter refers to both 

the  heat  meter  and  the  cooling  meter  unless  they  are 
otherwise differentiated. 

1. 

General 

1.1 

Use 

The T230 is used as a meter for heating or cooling consump-
tion measurement in systems with water. 
The meter consists of a high-tech plastic volume measurement 
unit, two temperature sensors connected in a fixed position and 
an electronic unit that calculates the energy consumption from 
the volume and temperature difference.  
The  meter  combines  modern  microcomputer  technology  with 
innovative  ultrasonic  measuring  technology  for  which  no  me-
chanically moving parts are necessary. 
This  technology  is  thus  wear  free,  robust  and  largely  mainte-
nance  free.  High  precision  and  long-term  stability  guarantee 
precise and equitable cost accounts. 

 

Note:

  The  meter  cannot  be  opened  without  damaging 

the security seal. 

1.2 

General notes 

The meter left the factory in a faultless condition where safety 
is  concerned.  The  manufacturer  will  provide  additional  tech-
nical support on request. Calibration relevant security seals on 
the  meter  must  not  be  damaged  or  removed.  Otherwise  the 
guarantee and calibration validity of the meter will lapse. 

 

Keep the packaging so that you can transport the meter in 
its original packaging following expiry of the calibration va-
lidity. 

 

Lay all cables at a minimum distance of 500 mm to high 
voltage and high frequency cables.  

 

A relative humidity of < 93% at 25 °C is permissible (without 
condensation). 

 

Avoid cavitation in the whole system due to overpressure 
i.e. at least 1 bar at qp and approx. 2 bar at qs (applies for 
approx. 80 °C). 

2. 

Safety Information 

 

The  meters  may  only  be  used  in  building  service 
engineering  plants  and  only  for  the  applications  de-
scribed. 

 

The  local  regulations  (installation  etc.)  must  be  ad-
hered to. 

 

Adhere  to  the  operating  conditions  according  to  the 
dial  plate  during  use.  Non-adherence can  cause  haz-
ards and the guarantee will lapse. 

 

Do not under any circumstances carrying out welding, 
drilling or soldering work close to the meter.

 

 

The  meter  is  only  suitable  for  circulating  water  in 
heating systems.

 

 

The meter is not suitable for drinking water.

 

 

Adhere to the AGFW requirements regarding circulat-
ing water (FW510).

 

 

 

Only  personnel,  trained  in  the  installation  and  opera-
tion  of  meters  in  heating  and  cooling  systems,  may 
install and remove the meter.

 

 

Only  install  or  remove  the  meter  when  the  pipes  are 
pressure-less.

 

 

After  installing  the  meter,  check  the  leak-tightness  of 
the system.

 

 

Guarantee  and  calibration  validity  will  lapse  if  the 
calibration relevant security seal is broken.

 

 

Only  clean  the  meter  from  outside  with  a  soft,  lightly 
wetted cloth. Do not use any spirit or cleaning solvent.

 

 

As far as disposal is concerned, the  meter is a waste 
electronic  appliance  in  the  sense  of  European  Di-
rective  2012/19/EU  (WEEE)  and  it  must  not  be  dis-
posed  of  as  domestic  waste.  The  relevant  national, 
legal  regulations  must  be  observed  as  the  appliance 
must be disposed of via the channels provided for this 
purpose. The local and currently valid legislation must 
be observed.

 

 

The meter contains lithium batteries. Do not dispose of 
the  meter  and  the  batteries  with  domestic  waste. 
Observe the local stipulations and laws on disposal. 

 

You can return the lithium batteries to the manufactur-
er  for  appropriate  disposal  following  use.  When  ship-
ping  please  observe  legal  regulations,  in  particular, 
those  governing  the  labelling  and  packaging  of  haz-
ardous goods.

 

 

Do  not  open  the batteries.  Do  not  bring batteries  into 
contact  with  water  or  expose  to  temperatures  above 
80 °C.

 

 

The  meter  does  not  have  any  lightning  protection. 
Ensure  lightning  protection  via  the  in-house  installa-
tion.

 

3. 

Installation 

To install the meter proceed as follows: 

 

Determine the place of installation in line with the inscrip-
tion on the meter. 

 

Note:

 At a 

heating meter

 the mounting place of the 

flow  sensor  cold  side  is  equivalent  to  return 

The  mounting  place  of  the  flow  sensor  hot  side  is 

equivalent to flow 

 

Note: 

At a 

cooling meter

 the mounting place of the 

flow sensor hot side is equivalent to the return 

The  mounting  place  of  the  flow  sensor  cold  side  is 

equivalent to flow 

 

Observe the dimensions of the meter and check whether 
there is sufficient space available. 

 

Rinse the system thoroughly before installing the meter. 

 

Fit the meter vertically or horizontally between two slide 
valves so that the arrow on the housing and the flow direc-
tion match. Also observe the installation situations and the 
following examples of installation. 

 

Note:

  Only  use  the  rubber  EPDM  flat  seals  that  are 

supplied. 

3

2

 1

8

 1

0

1

 0

0

3

 g

 

Summary of Contents for ULTRAHEAT T230

Page 1: ...systems The meter is not suitable for drinking water Adhere to the AGFW requirements regarding circulat ing water FW510 Only personnel trained in the installation and opera tion of meters in heating and cooling systems may install and remove the meter Only install or remove the meter when the pipes are pressure less After installing the meter check the leak tightness of the system Guarantee and ca...

Page 2: ...the seal with cupling nut is sufficient Recommendation Do not install the meter on the pressure side of a pump Maintain a minimum distance of 10 x DN on the pressure side Note During installation it must be ensured that no water can enter the electronic unit during operation Examples of installation directly immersed sensor You can install the meter in any position e g vertically or hori zontally ...

Page 3: ...git LCD displaying various values Fig 6 LCD Number Description 1 Identification previous year value 2 Previous year value 3 Maxima 4 Previous month value 5 Identification previous month value 6 Activity display at flow 7 Calibrated value Switching the display Proceed as follows to switch between the display values Press the button briefly for less than 2 sec to show the next line of the current lo...

Page 4: ...ation thresholds are exceeded and flow and temperature difference are positive the meter summates the energy and the volume If the operate margin is gone below a u is displayed at a leading point for the flow power and temperature display For a positive flow the activity display appears in the user loop in the LCD All segments of the display are switched on for control purpos es during the segment...

Page 5: ...5 mm Temperature range 0 95 C Volume measurement unit Protection class IP 65 according to EN 60529 Mounting place Hot side cold side Installation position Any Flow straightening None Measuring range 1 100 Temperature range 5 90 C National type approvals may be different Maximum overload qs 2 x qp permanent Nominal pressure PN16 1 6 MPa PS16 qp m h Overall length and connection 0 6 110 mm 3 4 1 5 1...

Page 6: ...Landis Gyr GmbH Subject to change without prior notice 13 06 2017 6 10 Declaration of conformity Landis Gyr GmbH Humboldtstrasse 64 90459 Nuremberg Germany ...

Reviews: