14
Focus kWh provides two scalable TTL-level pulse outputs for interfacing with pulse accumulating AMR modules.
Each output is user configurable to function in one of two operating modes.
Mode 1:Quadrature Pulse
AMR pulse output #1 responds to energy accumulation in the +kWh register. AMR pulse output #2 responds to
energy accumulation in the –kWh register. The relative timing of the two pulses satisfies the requirements of a
disk pickup application with the ability to determine the direction of disk rotation. The energy represented by
each pulse is scaled by the meter’s Ke value.
Mode 2: DifferkWh Pulse
AMR pulse outputs #1 & #2 respond to energy accumulation in the +kWh register. The output #2 pulse polarity
is opposite of the output #1 pulse polarity (consistent with form C outputs). The energy represented by each
pulse is scaled by the meter’s Ke value.