TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
BURNER WILL
NOT LIGHT
(continued)
Heavy sooting on coil and burner
can cause interruption of air flow
and shorting of electrodes.
Clean as required.
Improper electrode setting
Clean and set according to diagram in Operator's
Manual.
Fuel not reaching combustion
chamber
Check fuel pump for proper flow. Check solenoid flow
switch on machines with spray gun control for proper
on-off fuel flow control.
Clogged burner nozzle
Replace.
Water not flowing through flow
switch
Open spray gun to allow water to flow.
Flow switch malfunction
Remove reed and test for continuity. Replace if needed.
Fuel solenoid malfunction
Replace if needed.
UNIT SMOKES
Improper fuel or water in fuel
Drain tank and replace contaminated fuel.
Improper air adjustment
Readjust air bands on burner assembly.
Low fuel pressure
Call technical support.
Air leaks in fuel lines
Check fuel lines for leaks or air bubbles. Tighten or
replace as needed.
Plugged or dirty burner nozzle
Replace.
Faulty burner nozzle spray pattern
Replace nozzle.
Heavy accumulation of soot on
coils and burner assembly
Remove coils and burner assembly. Clean thoroughly.
Misaligned electrode
Call technical support.
Obstruction in smoke stack
Check for insulation blockage or other foreign objects.
LOW WATER
TEMPERATURE
Improper fuel or water in fuel
Drain fuel tank and replace with proper fuel.
Low fuel pressure
Increase fuel pressure.
Weak fuel pump
Check fuel pump pressure. Replace pump if needed.
Fuel filter partially clogged
Replace if needed.
Soot build-up on coils
Clean coils with soot remover.
Lime build-up in coils
Clean inside of coils with coil clean.
Improper burner nozzle
See tank assembly parts list for correct nozzle.