background image

15

Maintenance

It is advisable, periodically, to visually inspect the 

burner. Check air inlet to make sure it is not clogged or 

blocked. Wipe off any oil spills and keep equipment 

clean and dry.
The flow of combustion and ventilating air to the burner 

must not be blocked or obstructed in any manner.
The area around the Landa washer should be kept 

clean and free of combustible materials, gasoline and 

other flammable vapors and liquids.

Unloader Valves

WARNING: Unloader valves are preset and tested 

at the factory before shipping. Tampering with the 

factory setting may cause personal injury and/or 

property damage, and will void the manufacturers 

warranty. 
AVERTISSEMENT: La soupape de décompression 

sur cette laveuse à pression a été réglée en usine, 

puis scellée, et est une pièce non réglable. L'altéra

-

tion du paramètre de l'usine pourrait causer des 

lésions corporelles et/ou des dommages à la 

propriété, et annulera la garantie du fabricant.

Winterizing Procedure

Damage due to freezing is not covered by warranty. 

Adhere to the following cold weather procedures 

whenever the washer must be stored or operated 

outdoors under freezing conditions.
During winter months, when temperatures drop below 

32°F, protecting your machine against freezing is 

necessary. Store the machine in a heated room. If this 

is not possible then mix a 50/50 solution of anti-freeze 

and water in the float tank. Turn the engine on to siphon 

the anti-freeze mixture through the machine. If 

compressed air is available, an air fitting can be 

screwed into the float tank by removing the float tank 

strainer and fitting. Then inject the compressed air. 

Water will be blown out of the machine when the trigger 

on the spray gun is opened.

High Limit Hot Water Thermostat

For safety, each machine is equipped with a tempera

-

ture sensitive high limit control switch. In the event that 

the water should exceed its operating temperature, the 

high limit control will turn the burner off until the water 

cools then automatically reset itself. The thermostat 

sensor is located on the discharge side of the heating 

coil. The thermostat control dial is located on the 

control panel.

Pumps

Use only SAE 10W-40 non-foaming oil. Change oil after 

first 50 hours of use. Thereafter, change oil every year 

or at 500 hour intervals. Oil level should be checked 

through use of dipstick found on top of pump, or the red 

dot visible through the oil gauge window. Oil should be 

maintained at that level.

Cleaning of Coils

In alkaline water areas, lime deposits can accumulate 

rapidly inside the heating coil. This growth is increased 

by the extreme heat build up in the coil. The best 

preventative for liming conditions is to use high quality 

cleaning detergents. In areas where alkaline water is 

an extreme problem, periodic use of Landa Coil 

Descaler (part #8.914-296.0) will remove lime and 

other deposits before coil becomes plugged.

Periodic descaling of the heating coil is recom

-

mended so please consult your local Landa Dealer 

for instructions.

Removal of Soot and Heating Coil

In the heating process, fuel residue in the form of soot 

deposits may develop between the heating coil pipe 

and block air flow which will affect burner combustion. 

When soot has been detected on visual observation, 

the soot on the coil must be washed off after following 

the coil removal steps (See Coil Removal).

Rupture Disk

If pressure from pump or thermal expansion should 

exceed safe limits, the rupture disk will burst allowing 

high pressure to be discharged through hose to 

ground. When disk ruptures it will need to be 

replaced.he Rupture Disk should be replaced every 

two years.

Landa PGHW Operator’s Manual   8.916-485.0 - BW

Summary of Contents for PGHW4-3000

Page 1: ...ty XXXX XXX XXXX XX X XXXX XXX XXXX XX XXXX XXX XXXX GAS 8 916 274 0 DIE SEL 8 932 960 0 MODELS PGHW4 3000 1 110 048 0 PGHW4 4000 1 110 047 0 PGHW5 3000 1 110 046 0 PGHW5 3500 1 110 045 0 PGHW8 3000 1...

Page 2: ...2 Landa PGHW Operator s Manual 8 916 485 0 BW Machine Data Label...

Page 3: ...ions 10 Battery Installation 10 Operation Instructions 11 Detergents General Cleaning Techniques 12 Thermal Pump Protection 12 Cleaning Tips 12 Shutting Down And Clean Up 13 Maintenance Storage 14 Aft...

Page 4: ...ion and function of the machine The MAINTENANCE section contains preventive main tenance to keep the machine and its components in good working condition They are listed in this general order Storage...

Page 5: ...by trained opera tors Important Safety Information WARNING To reduce the risk of injury read operating instructions carefully before using AVERTISSEMENT Pour r duire le risque de blessures lire attent...

Page 6: ...fueling If any fuel is spilled make sure the area is dry before testing the spark plug or starting the engine Fire and or explosion may occur if this is not done Gasoline engines on mobile or portable...

Page 7: ...des dommages l quipement Se tenir l cart de la buse Faire preuve de prudence lors de l utilisation Ne pas d charger directement le jet vers des personnes ou des animaux car cela risquerait de causer...

Page 8: ...100 before stopping the machine Then open the spray gun to relieve pressure Failure to properly cool down or maintain the heating coil may result in a steam explosion 26 Do not overreach or stand on u...

Page 9: ...tergent Valve Engine Switch Fuel Cap Hose Reel Garden Hose Not Included High Pressure Nozzle Spray Wand Pillow Tank Spray Gun Water Connection Hose Valve Assembly High Pressure Hose Float Tank Burner...

Page 10: ...Install proper battery making sure that the red cable is attached to the positive terminal Use a 12V Group 24 battery on all models except 4 40321 and 5 35321E These models use a U1 30 amp garden tra...

Page 11: ...t water turn the burner switch to ON when a steady stream of water flows out of the spray gun Burner will now light automatically NOTE Do not start machine with burner switch on STEP 3 Pull wand coupl...

Page 12: ...pump protector engages and cools the pump by discharging the warm water onto the ground This thermal device prevents internal damage to the pump Cleaning Tips Pre rinse cleaning surface with fresh wa...

Page 13: ...10 Burner Switch Se nD EC TAC H H OU R 1 10 Engine Key Switch Liquides contenant des solvants c d diluant peinture essence huiles etc Produits base de tripolyphosphate de sodium Ammoniac ou produits b...

Page 14: ...flame or sparks NOTE The use of a fuel additive such as STA BIL or an equivalent will minimize the formulation of fuel deposits during storage Such additives may be added to gasoline in fuel tank of t...

Page 15: ...hermostat For safety each machine is equipped with a tempera ture sensitive high limit control switch In the event that the water should exceed its operating temperature the high limit control will tu...

Page 16: ...low 130 PSI when checked at the post pump pressure port The fuel pressure may need to be adjusted due to altitude For every 500 ft altitude above sea level the boiling point of water goes down 1 F At...

Page 17: ...ocal state and federal regulations CAUTION If white smoke appears from burner exhaust vent during start up or operation discon tinue use and readjust air bands ATTENTION Si de la fum e blanche s chapp...

Page 18: ...n Leaking pressure control valve Rebuild or replace as needed Slow engine RPM Set engine speed at proper specifications Pump sucking air Check water supply and possibility of air seepage Valves sticki...

Page 19: ...ne altitude The gasoline engine is preset for operation at altitudes below 1000 feet above sea level If operated at higher altitudes it may be necessary to install a high altitude main jet in the carb...

Page 20: ...ce Incorrect fuel nozzle size See specifications for proper fuel nozzle Insufficient water supplied Check water G P M to machine Restricted water flow Check nozzle for obstruction proper size PUMP NOI...

Page 21: ...nt line s Repair hole Low detergent level Add detergent if needed PUMP RUNNING NORMALLY BUT PRESSURE LOW ON INSTALLATION Pump sucking air Check water supply and possibility of air seepage Valves stick...

Page 22: ...ent Contact your Landa dealer for maintenance Regular preventative maintenance will add many hours to the life of your pressure washer Perform maintenance more often under severe conditions Maintenanc...

Page 23: ...e pump oil after first 50 hours and every year or 500 hours thereafter Use SAE 10W 40 non foaming oil DateOilChanged Month Day Year Estimated Operating Hours Since Last Oil Change DateOilChanged Month...

Page 24: ...8 916 485 0 Printed in U S A...