background image

PE SERIES PRESSURE WASHER  

OPERATOR’S MANUAL

5

LANDA PE • REV 10/02

PRE-OPERATION CHECK

 Pump oil (SAE 30W non-detergent oil)

 Cold water supply (6 gpm •

 

5/8" • 20 psi)

 Hose, wand, nozzle (nozzle size per serial plate)

 Water filter (intact, non restrictive)

SET-UP PROCEDURES

Attach a 5/8" garden hose to inlet connector. Mini-
mum flow should be 6 gpm.

Attach high pressure hose to discharge nipple using
quick coupler. Lock coupler securely into place by
pulling back coupler collar and inserting it onto dis-
charge nipple, then pushing collar forward to lock in
place. (Also see page 4).

Attach wand to spray gun using teflon tape on threads
to prevent leakage.

Attach swivel connector on discharge hose to spray
gun using teflon tape on threads.

Remove oil plug on top of pressure washer pump
and replace with dipstick supplied.  (This may be
installed from the factory.)

Check oil level on sight glass on back of pump. Oil
should be visible one half way up sight glass (30W
non-detergent).

For operator safety and to comply with electrical stan-
dards, the PE3-11021D comes with a 120V 20 amp
plug end that will fit only into a 20 amp receptacle.

On 230V and 460V machines, attach appropriate
plug end (not included) to power cord.

Pressure Hose

Filter

Garden Hose

Inlet Connector

Collar

Discharge

Nipple

Dipstick

Sightglass

OPERATING INSTRUCTIONS

  1. With power switch in OFF position, plug power cord

into a grounded type of receptacle of proper voltage
and amperage reading. Then push GFCI reset but-
ton at end of power cord if required.

  2. Turn on water at faucet and pull trigger on spray gun

allowing  water to flow until all air has discharged
from system. Check for water leaks; tighten as
needed.

  3. Pull  wand  coupler  collar

back and insert pressure
nozzle into coupler then
secure by pushing collar
forward to lock.

  4. With spray gun off, push

green star t switch/toggle
switch to ON position and check for leaks.

5. With spray nozzle pointed away from you or any-

body else, press trigger on spray gun to obtain pres-
surized spray.

GENERAL
WASHING TECHNIQUES

Test pressure and spray pattern on hard surface (i.e.
cement) to gauge distance and impact of water spray.

Hold spray nozzle approximately one foot from sur-
face being cleaned. For best surface cleaning ac-
tion, spray at slight angle.

To change spray nozzle for a different pattern it is
recommended that you turn off machine and
squeeze spray gun trigger to release hose pressure.
Pull back on quick coupler at end of wand and ex-
change nozzle. Make sure nozzle is seated securely.
Restart machine.

Use the detergent injector to apply detergent.  Wash
from the bottom and work up. Allow the detergent to
set 5-10 minutes on surface. Rinse from top down.

NOTE: 

If pressure washer is running and not being

used for more than 3 minutes, turn off machine.

Spray Nozzle

Quick Coupler

Wand

1 Foot

Summary of Contents for PE3-1100

Page 1: ...UAL LANDA INC 4275 N W Pacific Rim Blvd Camas WA 98607 USA For technical assistance or the Landa Dealer nearest you call 800 LANDA 4 U 800 526 3248 or 360 833 9100 or consult our web page at www landa...

Page 2: ...p in a safe place for future reference Introduction 3 Important Safety Instructions 3 4 Component Identification 4 Pre Operation Check 5 Set Up Procedures 5 Operating Instructions 5 General Washing Te...

Page 3: ...ntrols 3 Stay alert watch what you are doing 4 All installations must comply with local codes Con tact your electrician plumber utility company or the selling distributor for specific details To compl...

Page 4: ...t be cold and clean fresh water 16 To reduce the risk of injury close supervision is nec essary when a machine is used near children Do not allow children to operate the pressure washer This machine m...

Page 5: ...INSTRUCTIONS 1 With power switch in OFF position plug power cord into a grounded type of receptacle of proper voltage and amperage reading Then push GFCI reset but ton at end of power cord if require...

Page 6: ...ay gun to re lease pressure before removing discharge hose STORAGE Pump Storage CAUTION Always store your pressure washer in a location where the tem perature will not fall below 32 F 0 C The pump in...

Page 7: ...nto the quick coupler of the wand 7 Open spray gun Water detergent ratio is approxi mately 15 to 1 8 When you finish washing rinse by simply releasing the spray gun removing the soap nozzle and re pla...

Page 8: ...4 20021A B C PE4 30021A B C PE5 30021A B C F EXPLODED VIEW LEFT SIDE 7 4 5 47 60 59 61 46 58 53 57 29 27 24 28 36 68 66 64 63 65 67 3 1 2 69 48 37 48 5 6 5 5 5 6 5 76 9 9 5 8 43 44 45 7 5 48 48 5 18 2...

Page 9: ...EWASHER OPERATOR S MANUAL 9 LANDA PE REV 10 02 PE3 11021D PE4 20021A B C PE4 30021A B C PE5 30021A B C F EXPLODED VIEW RIGHT SIDE 41 40 72 34 33 22 26 29 55 56 20 30 32 31 5 6 5 6 10 15 16 14 6 5 12b...

Page 10: ...PE 1 95 07101022 Bracket Electric Box 4 3000A 5 3000A 1 24 10 08018 Label Warning Service Cord 1 25 2 0106 Cushion Pump 2 26 5 3022 Unloader General YVB75L EZ 3 1100 1 5 3025 Unloader General YVB75K47...

Page 11: ...PH 1725 230V 1 PH 4 2000A 1 5 1011 Motor 6 HP 3 PH 1725 230V 460V 3 PH 4 2000B C 1 ITEM PART NO DESCRIPTION QTY 42 5 1018 Motor 10 HP 3 PH 1725 230V 460V 3 PH 5 30021B C 1 5 1013 Motor 7 5 HP 1 PH 17...

Page 12: ...e Fiberglass Nema 4X except 3 1100 1 6 03909 Box Plastic 10 x 8 x 6 4 3000A 5 3000A 1 PE3 11021D PE4 20021A B C PE4 30021A B C PE5 30021A B C F EXPLODED VIEW PARTS LIST CONTINUED ITEM PART NO DESCRIPT...

Page 13: ...ON QTY 4 4 011231 Cover Wand All Models 1 5 Nozzles See Page 10 6 4 16540 Brass Soap Nozzle 1 7 4 011183 Detergent Injector 3 1100 1 4 011184 Detergent Injector All Models 1 8 2 2000 Coupler 1 4 Femal...

Page 14: ...loader valve seat worn Check and replace if necessary Worn piston package Check and replace if necessary PUMP NOISY Air in suction line Check water supply and connections on suction line Broken or wea...

Page 15: ...ld be approximately equal to isolate and correct the problem Over voltage or under voltage Check input voltage at each phase to motor Open stator winding Check stator resistance at all three phases fo...

Page 16: ...n WARNING Do not touch electrical connections before you first ensure that power has been disconnected Electrical shock can cause serious or fatal injury Only qualified personnel should attempt the in...

Page 17: ...rvice including adjustments fuel system cleaning and clearing of obstructions 6 Transportation to service center field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While...

Page 18: ...de alta presi n lejos del cableado electrico ya que puede ocurrir un choque fatal Lea la etiqueta de advertencia del cable electrico 3 Para proteger al operador de un choque el ctrico la m quina deber...

Page 19: ...a de Alta Presi n Manguera Para Detergentes Manguera de Suministro de Agua no se incluye Medidor de Aceite Mirilla de Nivel de Aceite Conector no incluido on unidades de 230v 1fase Switch de Encendido...

Page 20: ...r a 6 gpm 5 8 20 psi Manguera varilla boquilla tama o de boquilla seg n placa de serie Filtro de agua intacto no restrictivo Apropiada fuante el ctrica recept culo y caja de circuitos PROCEDIMIENTOS D...

Page 21: ...avar Riegue a cierto ngulo a modo que golp e debajo de la mugre o materia y la deprenda 2 Cuando este lavando objetos grandes use un inyector detergente pcional para aplicar el detergente Empiece el l...

Page 22: ...n del flujo 2 Conecte la manguera de descarga a presi n a la boquilla de inyector asegurando el conector r pido 3 Arranque la m quina como se indica en las instrucciones de operaci n 4 Coloque el tub...

Page 23: ...a 4 Da o a los componentes debido a fluctuaciones en el suministro el ctrico o al abastecimiento de agua 5 Servicio de mantenimiento normal incluso los ajustes limpieza del sistema de combustible y de...

Page 24: ...4275 NW Pacific Rim Blvd Camas WA 98607 USA Form 96 604 Revised 10 02 Printed in U S A by Landa Inc Camas WA 98607 WATER CLEANING SYSTEMS...

Reviews: