TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

PUMP RUNNING
NORMALLY BUT
PRESSURE LOW
ON INSTALLATION

Pump sucking air

Check water supply and possibility of air 
seepage.

Check valves sticking

Check and clean or replace if necessary.

Unloader valve seat faulty

Check and replace if necessary.

Nozzle incorrectly sized

Check and replace if necessary.

Worn piston packing

Check and replace if necessary.

FLUCTUATING
PRESSURE

Valves worn

Check and replace if necessary.

Blockage in valve

Check and clean out if necessary.

Faulty or misadjusted 
unloader valve

Tampering with the factory setting may 
cause personal injury and/or property 
damage, and will void the 
manufacturer's warranty.

Pump sucking air

Check water supply connections.

Worn piston packing

Check and replace if necessary.

Insuffi cient water

Check fi lter and hose for breakage.

PRESSURE LOW
AFTER PERIOD OF
NORMAL USE

Nozzle worn

Check and replace if necessary.

Suction or delivery valves worn

Check and replace if necessary.

Suction or delivery valves blocked

Check and clean if necessary.

Unloader valve seat worn

Check and replace if necessary.

Worn piston package

Check and replace if necessary.

PUMP NOISY

Air in suction line

Check water supply and connections on 
suction line.

Broken or weak suction or delivery 
valve spring

Check and replace if necessary.

Foreign matter in valves

Check and clean if necessary.

Worn bearings

Check and replace if necessary.

Excessive temperature of water

Reduce to below 140°F.

PRESENCE OF WATER
IN PUMP OIL

Oil seal worn

Check and replace if necessary.

High humidity in air

Check and change oil twice as often.

Piston packing worn

Check and replace if necessary.

WATER DRIPPING 
FROM UNDER PUMP

Piston packing worn

Check and replace if necessary.

O-Ring plunger retainer worn

Check and replace if necessary.

WATER DRIPPING 
FROM PUMP
PROTECTOR

Water supply pressure too high 
(over 90 psi)

Lower water supply pressure using a 
regulator.

Spray gun is in the off position for 
over 1-2 minutes

Turn machine off if not in use for over 1-2 
minutes.

OIL DRIPPING

Oil seal worn

Check and replace if necessary.

EXCESSIVE VIBRATION 
IN HIGH-PRESSURE 
HOSE

Irregular functioning of the pump 
valves

Check and replace if necessary

Summary of Contents for MPE5-50024B

Page 1: ...OPERATOR S MANUAL For technical assistance or the dealer nearest you consult our web page at www landa com MPE5 50024B MPE5 50024C LISTED 8 914 000 0 MPE...

Page 2: ......

Page 3: ...on a decal attached to the pressure washer You should record both serial number and date of purchase and keep in a safe place for future reference Important Safety Information 2 3 Component Identific...

Page 4: ...ian plumber utility company or the selling distributor for specific details If your machine is rated 250 volts or less single phase will be pro vided with a ground fault circuit interrupter GFCI If ra...

Page 5: ...FROM FREEZING WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is important you protect machine from freezing Failure to protect machine from freezing could ca...

Page 6: ...ne end to water pump high pressure discharge nipple and the other end to spray gun Rupture Disk Secondary pressure release in the unlikely event the unloader valve fails Unloader Valve Safety device w...

Page 7: ...le to make sure it is seated properly Pressure Nozzle Wand Coupler Wand Collar STEP 1 Attach the high pressure hose to the spray gun using teflon tape on hose threads Safety Latch Spray Gun High Press...

Page 8: ...er Safety Latch WA RN ING WA RN ING STEP 1 Connect machine to ad equate power source Push reset button on GFCI if equipped STEP 3 Turn machine on The five color coded quick con nect nozzles provide a...

Page 9: ...age to the pump CLEANING TIPS Pre rinse cleaning surface with fresh water Place de tergent suction tube directly into cleaning solution and apply to surface at low pressure for best results limit your...

Page 10: ...TION Pump Storage CAUTION Always store your pres sure washer in a location where the temperature will not fall below 32 F 0 C The pump in this machine is susceptible to permanent damage if frozen FREE...

Page 11: ...Check and replace if necessary Suction or delivery valves blocked Check and clean if necessary Unloader valve seat worn Check and replace if necessary Worn piston package Check and replace if necessar...

Page 12: ...s to the life of your pressure washer Perform maintenance more often under severe conditions OIL CHANGE RECORD Check pump oil and engine oil level before first use of your new pressure washer Pump Oil...

Page 13: ...and HD 1 3 9 803 810 0 Nozzle SAQCMEG 0004 5 Red 1 9 803 811 0 Nozzle SAQCMEG 15045 Yellow 1 9 803 812 0 Nozzle SAQCMEG 25045 Green 1 9 803 813 0 Nozzle SAQCMEG 4004 5 White 1 9 802 311 0 Nozzle COMP...

Page 14: ...center field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While not required for warranty service we request that you register your LANDA pressure washer by returning t...

Page 15: ......

Page 16: ...Form 8 914 000 0 Revised 06 12 Printed in U S A or Mexico...

Reviews: