background image

6

Safety

Important Safety Information

WARNING: If you do not follow these instructions 
exactly, a fire or explosion may result, causing 
property damage, personal injury or loss of life.

WARNING: To reduce the risk of 
injury, read operating instructions 
carefully before using.

1.

Read the owner's manual thor-
oughly. Failure to follow instruc-
tions and warnings could cause 
malfunction of the machine and 
result in death, serious bodily 
injury and/or property damage.

2.

Know how to stop the machine and bleed pressure 
quickly. Be thoroughly familiar with the controls.

3.

Stay alert — watch what you are doing.

4.

Use only your hand to push in or turn the gas 
control knob. Never use a tool. If the knob will not 
push in or turn by hand, don't try to repair it; call a 
qualified service technician.

5.

All installations must comply with local codes. 
Contact your electrician, plumber, utility company 
or the selling dealer for specific details.

DANGER: Improper connection of the equipment-
grounding conductor can result in a risk of electro-
cution. Check with a qualified electrician or service 
personnel if you are in doubt as to whether the 
outlet is properly grounded. 

DANGER: Keep wand, hose, and 
water spray away from electric 
wiring or fatal electric shock may 
result.

6.

To protect the operator from 
electrical shock, the machine 
must be electrically grounded. It 
is the responsibility of the owner 
to connect this machine to a 
grounded receptacle of proper 

voltage and amperage ratings. Do not spray water 
on or near electrical components. Do not touch 
machine with wet hands or while standing in water. 
Always disconnect power before servicing.

WARNING: Flammable liquids can 
create fumes which can ignite, 
causing property damage or 
severe injury.

WARNING: Risk of explosion — 
Operate only where open flame or 
torch is permitted. Do not spray 
flammable liquids.

WARNING: Risk of fire — Do not 
change LP tanks when the 
product is operating or still hot. 

WARNING: Use vapor fuel only.

7.

Gas appliances shall be 
installed only in locations where 
combustible dusts and 
flammable gases or vapors are 
not present. Do not store or use                       

 flammable materials near this machine.

WARNING: In the event of a pilot outage, wait at 
least five minutes to clear out any gas before 
relighting.

8.

Keep operating area clear of all persons.

WARNING: High pressure spray 
can cause paint chips or other 
particles to become airborne and 
fly at high speeds. To avoid 
personal injury, eye, hand and 
foot safety devices must be worn.

9.

Always wear properly rated eye 
protection such as safety 
goggles or face shield while 
spraying. 

(Safety glasses do not provide full protection)

Landa ENG Dealer’s Manual  9.801-510.0 - AV

DANGER

       

KEEP WATER 

 SPRAY AWAY FROM 

ELECTRICAL WIRING.

WARNING

    READ OPERATOR’S 

 MANUAL THOROUGHLY 

           PRIOR TO USE.

OPERATIONS

SAFET

Y

MAINTENANCE

WARNING

RISK OF EXPLOSION: 

IF GAS SMELL

 PRESENT TURN OFF

 SUPPLY 

WARNING

    USE PROTECTIVE 

  EYE WEAR 

AND CLOTHING

WHEN OPERATING

 THIS EQUIPMENT.

WARNING

RISK OF FIRE. 

DO NOT ADD FUEL 

WHEN OPERATING

MACHINE.

Summary of Contents for ENG4-2000

Page 1: ...T E DOIV ENT ETR E POR TEE S lorsq ue vous oper ez cet appa reil RISK OF ASP HYX IATI ON Use only in well vent i lated area RIES GO DE ASF IXIA Use el prod ucto en un area de venti laci n adec uada RI...

Page 2: ...e light is on it means the overload is tripped Reset overload Pilot Light When the light is on it means there is power to the pilot control If there is no light see troubleshooting guide Voltage When...

Page 3: ...les 26 Unloader Valves 26 Winterizing Procedure 26 Low Pressure Diagnosis 26 High Limit Hot Water Thermostat 26 Pumps 26 Heating Coils 26 Gas Valve Regulator Adjustment 27 Pressure Relief Valve 27 Pro...

Page 4: ...ep the machine and its components in good working condition They are listed in this general order Maintenance And Service Spray Nozzles Unloader Valves Winterizing Procedure Low Pressure Diagnosis Hig...

Page 5: ...he operator in the operator s native language by the purchaser owner making sure that the operator comprehends its contents Owner and or user must study and maintain for future reference the manufactu...

Page 6: ...machine to a grounded receptacle of proper voltage and amperage ratings Do not spray water on or near electrical components Do not touch machine with wet hands or while standing in water Always discon...

Page 7: ...RNING Protect machine from freezing 13 To keep machine in best operating conditions it is important you protect machine from freezing Failure to protect machine from freezing could cause malfunction o...

Page 8: ...roduce arcs or sparks Therefore when located in a garage it should be in a room or enclosure provided for the purpose or should be installed 18 457mm or more above the floor WARNING To reduce the risk...

Page 9: ...odically to be sure they are tight When testing for leaks use approved leak detector solution not matches 6 Make certain your container is properly fastened in place 7 Turn container with open part of...

Page 10: ...019 0 1 NIPPLE 3 4 X 2 BLACK 2 8 717 747 0 1 REGULATOR R622CFF FOR R932 28 R932462 3 8 717 746 0 1 REGULATOR HI PRESSURE R321H22 4 8 711 855 0 1 HOSE 1 2 X 19 PROPANE 5 8 717 782 0 1 FITTING PIGTAIL...

Page 11: ...FIC ADO S LIRE LE MAN UEL DE L OP ERA TEU R AVA NT UTIL ISAT ION CET APP ARE IL DOIT ETR E UTIL ISE PAR DES OPE RA TEU RS QUA LIFIE S RIS K OF INJU RY PRO TEC TIVE EYE WEA R AND CLO THIN G MUS T BE WO...

Page 12: ...l 19 50 Dia Customer Supplied Draft Diverter 24 00 24 87 4 00 High Pressure Out 3 8 QC Nipple 48 54 36 68 24 50 24 00 12 00 49 00 Water In 3 4 GHF 21 30 20 61 20 61 Exhaust Out 10 Dia NOTE Draft diver...

Page 13: ...Customer Supplied Draft Diverter Control Panel 61 00 17 33 34 79 17 36 26 18 3 64 High Pressure Out 3 8 QC Nipple 31 77 64 00 26 91 26 91 Water In 3 4 GHF Exhaust Out 12 Dia NOTE Draft diverter shoul...

Page 14: ...reas or near exhaust fans Gas Codes Confer with local gas company and with proper municipal officials regarding any specific code or regu lations governing the installation The installation must confo...

Page 15: ...h of bubbles If bubbles grow tighten or repair the connection as needed Repeat leak test until problem is corrected Check all tank and the line connections periodically to be sure they are tight When...

Page 16: ...cal codes In the absence of local codes refer to National Fuel Gas Code NFPA 54 and be constructed of materials approved by the Uniform Building Code Vents penetrating ceilings or walls should be doub...

Page 17: ...kinked the machine will run very rough and the burner will not fire Water Connection Connect the high pressure hose by pulling the coupler collar back and then inserting it onto the discharge nipple...

Page 18: ...n position 4 Start the pressure washer and allow it to heat up for at least 20 minutes before making any adjust ments 5 Note the values for Excess Air and or Oxygen 6 Close the damper in small increme...

Page 19: ...me to impinge on the regulator vent tubing if supplied It may clog and cause gas valve malfunction 9 DO NOT use the gas cock to adjust gas flow 10 If main burner fails to shut off turn off gas supply...

Page 20: ...r gases been removed from installation location Is there adequate gas supply for the BTU rating of the burner Is incoming gas supply pressure between 6 14 water column inches or 1 2 PSIG Has the prope...

Page 21: ...g nozzle turn on the water supply and run machine allowing water to run from the end of the wand until clear Turn off machine STEP 3 Connect garden hose to the cold water source STEP 6 Pull the spring...

Page 22: ...o pass through the pump NOTE Never run pump dry or leave spray gun closed longer than 3 minutes Landa ENG Dealer s Manual 9 801 510 0 AV O F F O N 8 1 0 1 2 1 4 1 6 0 2 4 6 TACH HO UR TACH HO UR IN ST...

Page 23: ...evice prevents internal damage to the pump Cleaning Tips Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solution and apply to surface For best results...

Page 24: ...et appareil e RIESGO DE ASFIXIA Use el producto en un area de venti laci n adecuad a RISQUE D ASPH YXIE Utiliser dans un endroit bien a r RISK OF ELECT ROCUT ION Connec t only to properl y ground ed o...

Page 25: ...r supply hose and high pressure hose 3 Turn on the machine for a few seconds until remaining water exits Turn pump off immediately 4 Do not allow high pressure hose to become kinked 5 Store the machin...

Page 26: ...y eliminating the unloader from the system and attaching the 50 discharge hose directly to the pump If high pressure is developed in this manner the pump is good and the unloader needs to be repaired...

Page 27: ...th propane systems Gas Pressure Requirements All propane fired machines operate on vapor propane fuel only They are designed to operate at a pressure of 11 w c i between 1 3 and 1 2 of one psi and are...

Page 28: ...ignition lines from the gas valve Disconnect union in main burner line below ther mostat Slide burner manifold out through shell opening 2 To Clean Burner Jets Select proper size drill for type gas in...

Page 29: ...3 39 BTU per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Number 125 91 Molecular Weight 44 09 58 12 To Calculate Run...

Page 30: ...ater column inches i e 11 w c i Higher pressures are expressed in terms of the force exerted against a square inch of area for example 125 lbs per square inch 125 psi Oil Change Record 1 Water Column...

Page 31: ...vere conditions Maintenance Schedule Replace Fuel Lines Annually Pump Oil SAE 10W 40 Non foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually Clean...

Page 32: ...High viscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent line s Repair hole Strainer basket plugged Remove and...

Page 33: ...acking kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with valve kit Obstruction in spray nozzle Remove obstruction Leakin...

Page 34: ...rned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals replace gas valve 3 Probe terminals PV and MV PV If 24 volts not pr...

Page 35: ...r sensor rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS OFF BEFORE THE BURNER SWITCH OR FLOW SWITCH IS TURNED OFF Dr...

Page 36: ...36 Notes Landa ENG Dealer s Manual 9 801 510 0 AV...

Page 37: ...37 Parts Parts LANDA ENG ENG4 2000 ENG4 2200 ENG4 3000 ENG5 2300 ENG5 3000 ENG6 3200 ENG8 3200 ENG10 3200 Landa ENG Dealer s Manual 9 801 510 0 AV...

Page 38: ...38 Frame NG 4 5 NG 4 2000 4 2200 4 3000 5 2300 5 3000 Landa ENG Dealer s Manual 9 801 510 0 AV 10 10 11 11 13 5 12 7 8 8 8 8 8 1 9 22...

Page 39: ...anual 9 801 510 0 AV Frame NG 4 5 NG 4 2000 4 2200 4 3000 5 2300 5 3000 GR OU ND 8 1 0 1 2 1 4 1 6 0 2 4 6 14 8 22 4 20 17 19 16 4 3 5 4 4 4 6 10 3 3 4 2 10 4 8 8 18 21 15 8 6 8 8 See Electrical Box a...

Page 40: ...KET DOOR LATCH 4 8 753 398 0 12 RIVET 3 16 LPST 5 8 718 625 0 25 BOLT 5 16 18 X 3 4 CRRG 6 9 802 778 0 12 NUT 5 16 WHIZ LOC 7 8 925 209 0 1 ASSY PUMP RAIL NG SM 8 8 753 397 0 81 RIVET 1 4 PRST 9 8 920...

Page 41: ...G SM 15 9 802 778 0 4 NUT 5 16 WHIZ LOC 9 802 781 0 4 NUT 3 8 WHIZ LOC 16 8 718 625 0 4 BOLT 5 16 18 X 3 4 CRRG 8 753 546 0 4 BOLT 3 8 X 1 CRRG 17 8 718 873 0 8 NUT RETAINER 5 16 8 751 125 0 5 NUT RET...

Page 42: ...ner NG 4 5 NG 4 2000 4 2200 4 3000 5 2300 5 3000 Landa ENG Dealer s Manual 9 801 510 0 AV O F F O N 1 5 11 11 10 7 9 8 19 8 7 16 15 6 12 14 9 13 22 18 20 21 23 2 17 4 3 To Coil Inlet To Unloader Valve...

Page 43: ...9 803 561 0 1 NIPPLE 3 4 X 5 BLACK PIPE 7 9 802 027 0 2 ELBOW 3 4 90 PIPE 8 9 802 019 0 2 NIPPLE 3 4 X 2 BLACK PIPE 9 9 802 049 0 2 UNION 3 4 BLACK PIPE 10 9 802 021 0 1 NIPPLE 3 4 X 9 BLACK PIPE 11...

Page 44: ...4 5 NG 4 2000 4 2200 4 3000 5 2300 5 3000 Landa ENG Dealer s Manual 9 801 510 0 AV O FF O N 24 14 6 2 1 11 15 28 13 9 8 27 30 29 16 31 25 17 21 20 26 21 7 10 5 23 22 18 19 4 3 See Burner Assy Illus Fo...

Page 45: ...0 1 PUSH ON 1 2 BARB X 3 8 MPT 14 9 802 259 0 40 HOSE 1 2 PUSH ON 15 8 706 167 0 1 ELBOW 3 8 FPT 90 DGR P N TF3509X6 16 8 715 967 0 36 WIRE NTW 16 GA GREEN 17 8 726 103 0 4 SCREW 1 4 20 X 5 8 WHIZ LO...

Page 46: ...46 Frame NG 6 10 NG 6 3200 8 3200 10 3000 Landa ENG Dealer s Manual 9 801 510 0 AV 9 1 7 11 13 8 8 9 5 22 10 10 8 8 22 12...

Page 47: ...a ENG Dealer s Manual 9 801 510 0 AV Frame NG 6 10 NG 6 3200 8 3200 10 3000 GRO UND 6 6 21 23 19 8 14 16 19 25 15 23 17 20 8 8 4 4 4 3 3 5 18 10 5 3 2 4 4 10 24 8 8 26 See Electrical Box assembly for...

Page 48: ...98 0 19 RIVET 3 16 LPST 5 8 718 625 0 25 BOLT 5 16 X 18 X 3 4 NC CRRGE ANC 6159 6 9 802 778 0 12 NUT 5 16 WHIZ LOC FLANGE 7 8 923 701 0 1 RAIL PUMP NG LM 8 8 753 397 0 103 RIVET 1 4 PRST 9 8 921 632 0...

Page 49: ...BOLT 3 8 16 X 1 CARRIAGE ZNC 17 8 751 125 0 5 NUT 3 8 PUSH BOLT RETAINER 18 8 921 651 0 1 PLATE MOTOR NG LM 19 8 706 547 0 12 GROMMET 1 2 X 1 X 1 2 20 8 921 385 0 1 MIRROR 21 8 921 627 0 1 BASE HALF...

Page 50: ...G 6 10 NG 6 3200 8 3200 10 3000 Landa ENG Dealer s Manual 9 801 510 0 AV HO NE YW EL L LO HI 12 11 14 10 20 18 11 19 22 6 2 15 16 5 3 4 9 8 17 1 21 9 13 31 11 23 24 To Coil Inlet 25 30 26 27 28 29 26...

Page 51: ...23 0 2 UNION 1 BLACK PIPE 10 8 706 021 0 2 NIPPLE 1 X 11 BLACK PIPE 11 8 706 183 0 2 ELBOW 1 STREET 90 BLACK 12 8 918 227 0 1 HOSE 1 2 X 36 2 WIRE PRESSURE LOOP 13 8 718 050 0 1 VALVE 1 NATURAL GAS 24...

Page 52: ...l NG 6 10 NG 6 3200 8 3200 10 3000 Landa ENG Dealer s Manual 9 801 510 0 AV HO NE YW ELL LO HI See Burner Assy Illus For Detail 26 27 2 5 10 11 12 14 18 6 9 8 15 30 21 7 3 16 17 23 13 20 22 25 19 24 2...

Page 53: ...PLE 1 2 X 4 GALV SCH 80 MPT 13 8 912 530 0 2 WLMT PLATE DISCHARGE COUPLING VNG 14 8 712 187 0 1 SWITCH SNAP 275 DR HI LIMIT 15 9 802 260 0 1 HOSE 5 8 16 9 802 024 0 1 ELBOW 3 8 MPT X 1 2 FPT STREET ST...

Page 54: ...54 Float Tank NG 4 5 NG 4 2000 4 2200 4 3000 5 2300 5 3000 Landa ENG Dealer s Manual 9 801 510 0 AV To Unloader To Water Inlet 16 15 5 7 2 1 6 11 13 15 14 4 17 3 8 8 9 10 12 12 10 19 18...

Page 55: ...743 0 2 BULKHEAD 1 2 POLYPRO 7 8 707 310 0 1 VALVE FLOAT BRASS 8 8 707 311 0 1 ADAPTER FLOAT VALVE 9 8 921 824 0 1 TANK FLOAT 2 6 GAL W HOLES 10 9 802 252 0 2 HOSE 1 4 BRAIDED VINYL 11 9 802 695 0 2...

Page 56: ...56 Float Tank NG 6 10 NG 6 3200 8 3200 10 3000 Landa ENG Dealer s Manual 9 801 510 0 AV 6 7 8 9 11 To Water Inlet To Pump To Pump To Unloader 1 2 3 5 10 13 1 16 16 1 1 2 2 15 4 16 14 12 4 18 17...

Page 57: ...00 10 3000 7 8 707 061 0 2 STRAINER 1 2 BASKET 6 3000 8 707 076 0 2 STRAINER 1 4 BASKET 8 3200 10 3000 8 8 706 925 0 2 BUSHING 3 4 X 1 2 6 3200 8 706 923 0 2 BUSHING 3 4 X 1 4 8 3200 10 3000 9 8 749 3...

Page 58: ...4 2200 4 3000 5 2300 5 3000 Landa ENG Dealer s Manual 9 801 510 0 AV Bypass Bypass To Float Tank Cool Bypass to Float Tank To Detergent Valve To Coil 9 8 7 16 11 10 4 12 13 14 5 4 18 8 9 1 2 3 15 Ste...

Page 59: ...8 COUNTERSUNK 7 8 706 965 0 1 HOSE BARB 1 4 BARB X 3 8 MPT 90 8 6 390 126 0 2 CLAMP HOSE 46 54 ST 9 9 802 252 0 24 HOSE 1 4 X 1 2 BRAIDED VINYL FT 10 9 802 632 0 1 CAP VALVE 24MM W 1 4 GAUGE PORT 11 9...

Page 60: ...3200 10 3000 Landa ENG Dealer s Manual 9 801 510 0 AV To Float Tank To Float Tank To Detergent Valve Cool Bypass To Coil 2 3 2 5 Steam Valve Option Steam Valve Option 1 7 17 15 16 14 6 12 4 2 8 11 10...

Page 61: ...8 706 852 0 1 CROSS 3 4 FEMALE PIPE P N 3950 12 10 8 706 923 0 2 BUSHING 3 4 X 1 4 BRASS 11 8 706 865 0 1 PLUG 1 4 NPT COUNTER SUNK 12 8 706 800 0 2 NIPPLE 3 4 HEX BRASS 8 3200 10 3000 8 706 881 0 2...

Page 62: ...62 Tensioner NG 4 5 NG 4 2000 4 2200 4 3000 5 2300 5 3000 Landa ENG Dealer s Manual 9 801 510 0 AV 1 9 2 4 5 See Pump Assy Illus For Detail 11 12 8 6 16 3 7 13 14 10 17 17 15 15 17...

Page 63: ...0 4 BOLT 10MM X 20MM HH ZINC 4 2200 4 3000 5 2300 5 3000 9 802 741 0 4 BOLT 8MM X 16MM 4 2200 6 8 718 961 0 4 WASHER M10 SPLT RING LCK8 8 CLSS ZINC PLTD 4 2200 4 3000 5 2300 5 3000 9 802 813 0 4 WASHE...

Page 64: ...64 Tensioner NG 6 10 NG 6 3200 8 3200 10 3000 Landa ENG Dealer s Manual 9 801 510 0 AV 6 4 See Pump Assy Illus For Detail 2 5 3 11 10 7 9 1 15 16 16 12 14 13 16...

Page 65: ...G H X 25MM 5 9 803 980 0 1 BUSHING P1 X 1 5 8 6 8 715 706 0 3 BELT BX46 6 3200 10 3000 8 715 708 0 3 BELT BX48 8 3200 7 8 921 648 0 1 BRACKET PULLEY TENSIONER LG LM 8 9 802 722 0 1 BOLT 3 8 X 1 1 4 NC...

Page 66: ...Torque Specifications Landa ENG Dealer s Manual 9 801 510 0 AV 3 1 2 434 in lbs 36 166 ft lbs 25 in lbs 2 08 ft lbs 9 ft lbs 108 in lbs 1 2 3 NOTE Orientation of item numbers 1 and 2 is dependent on...

Page 67: ...ealer s Manual 9 801 510 0 AV Tensioner Torque Specifications REF PART NO QTY DESCRIPTION NOTES 1 8 923 700 0 1 BRAKET TENSIONER ROSTA 2 8 749 975 0 1 TENSIONER ROSTA SE18 BELT 3 8 749 973 0 1 BUSHING...

Page 68: ...2000 4 2200 4 3000 5 2300 5 3000 Landa ENG Dealer s Manual 9 801 510 0 AV GR OU ND 1 3 12 4 11 4 5 19 12 11 17 21 18 11 20 30 22 12 5 34 12 29 7 10 8 9 9 31 12 6 12 32 12 27 13 14 15 16 24 26 25 2 2...

Page 69: ...8 921 397 0 1 COVER ELECTRICAL BOX REAR NG SM 9 8 726 103 0 4 SCREW 1 4 X 20 5 8 WHIZ LOC BLK CAD 10 8 716 883 0 1 TRANSFORMER 208 230 460 24 115V 050KVA 8 716 884 0 1 TRANSFORMER 100KVA 575V 24V 11 9...

Page 70: ...00B H 8 724 303 0 1 OVERLOAD XTOB010CC1DP 6 0 10 0 4 2200F 4 3000F 5 2300F 8 724 312 0 1 OVERLOAD XTOB016CC1DP 10 0 16 0 4 2200C 4 3000C 5 2300C 5 3000C F 8 724 307 0 1 OVERLOAD XTOB057DC1DP 40 0 57 0...

Page 71: ...8 8 900 207 0 1 LABEL INCOMING POWER 29 8 716 460 0 1 TERMINAL GROUND LUG LAMA6 14 Q 30 8 753 544 0 1 TERMINAL BLOCK 3 POLE 85 AMP 31 9 800 040 0 2 LABEL GROUND SYMBOL 32 9 802 762 0 1 SCREW 10 32 X 1...

Page 72: ...6 10 NG 6 3200 8 3200 10 3000 Landa ENG Dealer s Manual 9 801 510 0 AV GR OU ND 7 4 9 22 8 3 28 30 1 2 34 21 9 9 33 4 6 39 38 5 39 31 19 20 25 26 13 14 15 16 24 27 17 18 40 10 11 12 31 29 32 34 12 12...

Page 73: ...12 9 802 695 0 25 NUT 10 32 KEPS 13 8 749 980 0 2 TERMINAL BLOCK END CAP PHOENIX 14 8 749 976 0 8 TERMINAL BLOCK FEED THRU PHOENIX 15 9 804 595 0 2 END BRACKET ENTRELEC 103 002 26 16 8 753 064 0 4 TE...

Page 74: ...43 0 1 FUSE 4 AMP 26 8 713 080 0 2 FUSE CLASS R 1 AMP 208 230 1PH 3PH 8 713 081 0 2 FUSE CLASS R 1 2 AMP 460 575 3PH 27 8 718 730 0 1 SCREW 10 32 X 2 1 2 RND HD MCH 28 8 900 207 0 1 LABEL INCOMING POW...

Page 75: ...1 4 RH SL BLK 33 8 916 343 0 1 LABEL PE HE TESTED 34 9 802 764 0 4 SCREW 10 32 X 3 4 HEX WASH SL MACH BLK 35 9 802 785 0 2 NUT 8 32 KEPS 36 9 801 608 0 1 LABEL FUSE KTK 50 V 9 801 626 0 1 LABEL FUSE...

Page 76: ...Panel NG 4 5 NG 4 2000 4 2200 4 3000 5 2300 5 3000 Landa ENG Dealer s Manual 9 801 510 0 AV GR OU ND 8 1 0 1 2 1 4 1 6 0 2 4 6 TAC H H OUR 5 10 20 11 7 8 9 12 19 14 15 18 13 16 17 21 6 1 3 2 4 Steam V...

Page 77: ...712 350 0 1 NOZZLE SAQCMEG 1504 5 YELLOW 4 3000 8 712 354 0 1 NOZZLE SAQCMEG 1505 YELLOW 4 2000 8 712 366 0 1 NOZZLE SAQCMEG 1506 5 YELLOW 5 2300 9 9 712 359 0 1 NOZZLE SAQCMEG 4005 5 WHITE 4 2200 5 3...

Page 78: ...78 Control Panel NG 6 10 NG 6 3200 8 3200 10 3000 Landa ENG Dealer s Manual 9 801 510 0 AV GR OU ND TAC H H OUR 10 Steam Valve Option 6 22 7 8 9 11 19 13 4 3 2 2 1 5 12 20 15 14 16 17 21 18...

Page 79: ...1509 YELLOW 8 3200 8 707 763 0 1 NOZZLE 11 X 40 1 4 MEG 10 3000 9 8 712 372 0 1 NOZZLE SAQCMEG 4007 WHITE 6 3200 8 712 381 0 1 NOZZLE SAQCMEG 4009 8 707 761 0 1 NOZZLE 11 X 15 1 4 MEG 10 3000 10 9 80...

Page 80: ...in well venti lated area RIESGO DE ASFIXI A Use el product o en un area de venti laci n adecua da RISQU E D ASPH YXIE Utiliser dans un endroit bien a r RISK OF ELECT ROCU TION Conne ct only to proper...

Page 81: ...900 990 0 1 LABEL INSTRUCTIONS WARNING 10 9 800 016 0 1 LABEL DISCONNECT POWER 11 8 916 090 0 1 LABEL LANDA 12 8 900 207 0 1 LABEL INCOMING POWER 13 8 932 964 0 1 LABEL NATURAL GAS 14 9 800 020 0 1 L...

Page 82: ...IVENT ETRE PORTEE S lorsque vous operez cet appareil RISK OF ASPHYX IATION Use only in well venti lated area RIESGO DE ASFIXIA Use el producto en un area de venti laci n adecuada RISQUE D ASPHY XIE Ut...

Page 83: ...STRUCTIONS WARNINGS 10 9 800 016 0 1 LABEL DISCONNECT POWER SUPPLY 11 8 900 802 0 1 LABEL LANDA LOGO 25 75 X 6 0 12 8 900 207 0 1 LABEL INCOMING POWER 13 8 932 964 0 1 LABEL NATURAL GAS ONLY 14 9 800...

Page 84: ...84 Hose Spray Gun Landa ENG Dealer s Manual 9 801 510 0 AV 1 2 3 7 5 6 4...

Page 85: ...WHITE 4 22 5 3 8 712 349 0 1 NOZZLE 0004 5 RED 4 3 8 712 350 0 1 NOZZLE 1504 5 YELLOW 4 3 8 712 352 0 1 NOZZLE 4004 5 WHITE 4 3 8 712 353 0 1 NOZZLE 0005 RED 4 2A 8 712 354 0 1 NOZZLE 1505 YELLOW 4 2...

Page 86: ...T NO 6 3200 X 44 50 SEE PARTS LIST NO 8 3200 X 88 52 SEE PARTS LIST NO 10 3000 X 88 52 SEE PARTS LIST NO MODEL BURNER ASSEMBLY JET SIZE GAS VALVE PILOT ORIFICE CONVERSION 4 2000LP X 44 63 SEE PARTS LI...

Page 87: ...23024F LT6035R 8 904 881 0 2BK100 9 802 391 0 H25mm 9 802 403 0 ENG5 23024G LT6035R 8 904 881 0 2BK100 9 802 391 0 H25mm 9 802 403 0 ENG5 23024H LT6035R 8 904 881 0 2BK100 9 802 391 0 H25mm 9 802 403...

Page 88: ...23024G 8 2 HP 208V 1PH 8 715 162 0 2BK34 9 802 382 0 H x 1 1 8 9 802 400 0 BX48 2 8 715 708 0 ENG5 23024H 8 2 HP 208V 3PH 8 715 171 0 2BK36 9 802 383 0 H x 1 1 8 9 802 400 0 BX48 2 8 715 708 0 ENG5 3...

Page 89: ...8 713 081 0 4 Amp 8 749 743 0 ENG5 23024G 9 802 451 0 8 724 280 8 724 306 0 8 716 883 0 1 Amp 8 713 080 0 4 Amp 8 749 743 0 ENG5 23024H 9 802 451 0 8 724 275 0 8 724 304 0 8 716 883 0 1 Amp 8 713 080...

Page 90: ...OADER NOT SHOWN 8 750 710 0 REPAIR KIT VRT3 4500 PSI KIT ITEMS 3 9 11 25 26 28 Landa ENG Dealer s Manual 9 801 510 0 AV 24 14 15 16 17 18 19 23 27 35 25 26 25 40 23 23 23 22 21 20 4 1 3 5 6 7 8 9 11 1...

Page 91: ...and screw down until contact is made with the nuts Items 15 Screw down lock nut Item 19 onto the stem Item 8 until the threads cut into the nylon insert of the lock nut Item19 If adjustment knob Item...

Page 92: ...NOTES 8 754 012 0 REPAIR KIT VRT 100 UNLOADER KIT ITEMS 2 3 4 6 9 10 25 26 28 30 36 39 Landa ENG Dealer s Manual 9 801 510 0 AV 35 32 33 34 31 30 29 28 36 37 38 39 20 23 23 24 21 22 40 27 25 26 25 1 2...

Page 93: ...8 and screw down until contact is made with the nuts Items 15 Screw down lock nut Item 19 onto the stem Item 8 until the threads cut into the nylon insert of the lock nut Item19 If adjustment knob Ite...

Page 94: ...O RING 2 62 X 17 13 SEE KITS TABLE 12 6 VALVE ASSEMBLY SEE KITS TABLE 13 6 O RING 2 62 X 20 29 SEE KITS TABLE 14 9 802 928 0 6 VALVE PLUG 15 9 802 938 0 8 MANIFOLD STUD BOLT 16 9 802 884 0 16 WASHER...

Page 95: ...RING WASHER 43 9 803 238 0 6 CONNECTING ROD SCREW 44 8 933 016 0 1 O RING 2 62 X 126 67 45 8 751 229 0 1 CRANKCASE COVER 46 9 803 197 0 1 O RING 1 78 X 14 47 9 803 202 0 1 SIGHT GLASS 3 4 48 9 802 939...

Page 96: ...NG 11 9 804 498 0 6 O RING 2 62 X 25 1 SEE KITS TABLE 12 6 VALVE ASSEMBLY SEE KITS TABLE 13 9 803 193 0 6 O RING 3068 SEE KITS TABLE 14 9 802 928 0 6 VALVE PLUG 15 8 753 817 0 8 MANIFOLD STUD BOLT 16...

Page 97: ...5 8 752 820 0 3 BONDED SEAL SEE KITS TABLE 36 8 753 819 0 3 PLUNGER 18MM SEE KITS TABLE 37 8 752 823 0 3 COPPER SPACER SEE KITS TABLE 38 8 753 820 0 3 PLUNGER ROD 39 8 752 822 0 3 CONNECTING ROD PIN 4...

Page 98: ...803 287 0 6 O RING 3 53 X 25 80 134 SEE KITS TABLE 14 8 752 855 0 6 VALVE PLUG 15 8 752 833 0 8 MANIFOLD STUD BOLT 16 9 802 890 0 8 LOCK WASHER 17 9 803 199 0 1 COPPER WASHER 1 2 18 9 802 926 0 1 BRAS...

Page 99: ...35 8 752 820 0 3 BONDED SEAL SEE KITS TABLE 36 8 752 847 0 3 PLUNGER 22MM SEE KITS TABLE 37 8 752 823 0 3 COPPER SPACER SEE KITS TABLE 38 8 752 842 0 3 PLUNGER ROD 39 8 752 822 0 3 CONNECTING ROD PIN...

Page 100: ...1 PLUG BRASS G1 2 11 8 754 852 0 1 MANIFOLD 12 8 717 233 0 6 O RING 1 78 X 15 6 SEE TABLE KITS 13 6 VALVE ASSEMBLY SEE TABLE KITS 14 9 803 948 0 6 O RING 1 78 X 18 77 SEE TABLE KITS 15 9 803 949 0 6 V...

Page 101: ...STICK 35 8 933 010 0 1 SEAL CRANKSHAFT 36 8 754 855 0 3 BOLT PLUNGER SEE TABLE KITS 37 8 754 092 0 3 SPACER COPPER SEE TABLE KITS 38 8 754 848 0 3 PLUNGER 16 MM SEE TABLE KITS 39 9 803 962 0 3 SPACER...

Page 102: ...9 801 510 0 Printed in U S A...

Reviews: