Section 5: Maintenance & Lubrication
RC(L)4710 & RCM(L)4710 Rotary Cutters 334-863M
7/31/20
58
CV Driveline Joint Access
Figure 5-21
33994
8-10 pumps
Zerk Located through slot in tube
CV Driveline without overrunning clutch
23556
8-10 pumps
CV Driveline with overrunning clutch
39280
4-5 pumps
2-3 pumps
2-3 pumps
4-6 pumps
CV Driveline without overrunning clutch
23556
CV Driveline with overrunning clutch
39280
4-5 pumps
2-3 pumps
4-6 pumps
2-3 pumps
CV Main Driveline Profile Tubes
Type of Lubrication: Multi-purpose Grease
Frequency = Every 8 hours
Quantity = 8-10 pumps
IMPORTANT:
To extend the life of the constant
velocity joint, extensive lubrication must be
performed every 8 hours of operation.
CV Main Driveline Joints
Type of Lubrication: Multi-purpose Grease
Frequency = Every 8 hours
For instructions on how to access grease zerks shown
See
“Accessing CV Driveline Joints”
.
•
The constant velocity joint should be greased in a
straight position forcing grease through the passages
and into the cavity. After lubrication, grease should
be visible around the ball joints.
•
Grease fittings located on the u
-
joints, driveline
shields and overrunning clutch should be lubricated
every 8 hours of operation.
8
Hours
8
Hours
CV Main Driveline Shield Grease Point
Type of Lubrication: Multi-purpose Grease
Frequency = Every 8 hours
Quantity = 2-3 Pumps
8
Hours