Item Part No.

Description

-

82-1248/03 Refrigeration Deck Assembly, 

 

R-134A, 230 V/50 Hz, Export

-

82-1372/03

Refrigeration Deck Assembly, 

 

R-134A, 115 V/60 Hz, Domestic

1

51-2107/01

Sub-Assembly, Compressor Deck

2

50-0200/01

Insulation, Compressor Deck

3

04-0063

Flat Washer

4

89-0014

Hole Cover

5

82-1373/01

Evaporator Coil, R-134A

6

52-1773/02

Probe Assembly, IBC

7

04-0394

Screw, 6-32 x 0.500

8

51-0068

Handle

9

04-0574

Washer

10

52-0903/02

Control Housing Assembly

11

30-5118

Control Housing Cover

12

06-2221/02 Wiring Diagram Label

13

02-0032

Washer

14

04-0504/01

Screw, 8-18 x 0.375

15

52-1209

Lead Assembly, Ground

16

02-0041

Seal

17

REF

Capacitor, Carbonator

-

26-0374

Capacitor, Carbonator, 115 V/60 

Hz

-

12-0608

Capacitor, Carbonator, 230 V/50-

60 Hz

18

REF

Transformer

-

25-0047

Transformer, 115 V/60 Hz

-

25-0048

Transformer, 230 V/50-60 Hz

19

REF

Motor Assembly

-

52-1261

Motor Assembly, 115 V/60 Hz

-

52-1262

Motor Assembly, 230 V/50-60 Hz

20

30-5113

Agitator Bracket

21

05-0495/01

Propeller, 2.062” Diameter

22

05-0502

Propeller, 2.250” Diameter

23

02-0040

Extrusion Seal

24

04-0032/01 Nut, Nylok, 1/4 - 20

25

04-0033/01 Washer, Flat (0.281 ID)

26

83-0071

Compressor, R-134A, 115 V/60 

Hz, Domestic

-

83-0076

Compressor, R-134A, 230 V/50-60 

Hz, Export

27

02-0114

Grommet

Item Part No.

Description

28

04-0537

Washer, Flat (0.467 ID)

29

03-0150

Retainer Clip

30

REF

Relay

-

12-0612

Relay, 115 V/60 Hz

-

12-0607

Relay, 230 V/50-60 Hz

31

REF

Overload

-

12-0611

Overload, 115 V/60 Hz

-

12-0606

Overload, 230 V/50-60 Hz

32

13-0066

Cover Terminal

33

03-0040

Bale Strap

34

47-0344

Process Tube

35

47-0718

Compressor Tube (High Side)

36

47-0724

Return Tube (Low Side)

37

51-0061

Accumulator

38

50-0211

Boot

39

50-0205

Insulation Tube

40

50-0159

Insulation Tube

41

23-0985

Condenser

42

50-0201

Condenser Baffle

43

30-5112

Retainer Plate

44

04-0518

Rivet, 0.1250 x 0.328

45

30-5867

Air Shield, Left

46

30-5865/01

Fan Shroud, Top

47

50-0249

Barrier, Long

48

30-5866

Fan Shroud, Bottom

49

REF

Fan Motor

-

91-0007

Fan Motor, 115 V/60 Hz

-

91-0009

Fan Motor, 230 V/50-60 Hz

50

07-0354

Fan Blade

51

04-0060

Nut

52

02-0413

Silencer

53

30-5864

Fan Motor Bracket

54

23-0765

Dryer Cap Assembly

55

47-0698

Condenser Out Tube

56

52-2008 

Secondary Harness Assembly

57

04-0110

Nut, 8 - 32

58

04-0576

Washer, Int., Tooth

59

06-0877/01

Label, Ground

60

04-0059

Screw, 8-36 x 0.375

Summary of Contents for MAX II

Page 1: ...by Lancer all rights reserved 9000 Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Tech Support Warranty 800 729 1550 email custserv lancercorp com web lancercorp com Lancer P...

Page 2: ...llation WARNING Text following the Caution signal indicates a hazardous situation which if not avoided could result in death or serious injury Be sure to read the Caution statements before proceeding...

Page 3: ...d not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should service internal com ponents of electrical control housing WARNING...

Page 4: ...N WATER SUPPLY Min Pressure 25 psi 0 172 MPa Max Pressure 50 psi 0 345 MPa CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FITTINGS Water for Carbonator Inlet 3 8...

Page 5: ...etiker Clamp Fittings Water Booster Lancer PN 82 3401 or MC 163172 Water Regulator supplied with unit CONSIDER THE FOLLOWING BEFORE INSTALLATION Location of Water Supply Lines Location of Drain Locati...

Page 6: ...of the unit to provide for proper air flow and circulation Failure to maintain specified clearance will cause the compressor to overheat and will result in compressor failure ATTENTION Lancer recomme...

Page 7: ...e tubing from the water source to the carbonator pump inlet at the unit and connect tubing to water source Carefully read this before filling the water bath tank In order to optimize the maximum perfo...

Page 8: ...t have a separate electrical circuit Do not use extension cords Do not connect multiple electrical devices on the same outlet WARNING 16 Route appropriate tubing from the syrup pump location to the CO...

Page 9: ...pump and void the warranty F ATTENTION A Relief Valve Open B CO2 Inlet C CO2 Line A B C 1 Purge water to fill carbonator tank by opening carbonator relief valve Close relief valve once water comes ou...

Page 10: ...move nozzle by twisting counter clockwise and pulling down then remove diffuser by pulling down 6 Re open syrup shut off at mounting block 7 Activate valve to purge syrup until steady flow is achieved...

Page 11: ...d Instruction warnings on the product being used must be followed Use sanitary gloves when cleaning the unit and observe all applicable safety precautions DO NOT use a water jet to clean or sanitize t...

Page 12: ...warm water 5 Wash nozzle and diffuser with cleaning solution then immerse in sanitizing solution and let sit for fifteen 15 minutes 6 Set nozzle and diffuser aside and let air dry DO NOT rinse with wa...

Page 13: ...bris in syrup flow control 5 Bad syrup pump 1 Adjust CO2 pressure to 80 psi 0 550 MPa minimum 70 psi 0 480 MPa for BIB pumps 2 Replace CO2 tank refill 3 Open shutoff fully 4 Remove syrup flow control...

Page 14: ...ind leak and recharge unit If unit is not frozen 6 Turn water ON and shut unit OFF 7 Turn unit OFF then ON to reset 8 Replace PCB Assembly Valve will not shut off 1 Cup lever may be sticking or bindin...

Page 15: ...t leak 5 Condenser fan motor not working 6 Dirty condenser 7 Dispenser capacity exceeded 1 Check clearances around sides top and inlet of unit Remove objects blocking airflow through grill 2 Switch to...

Page 16: ...Measure voltage across common and run terminal on compressor Voltage must not drop below 90 of rated voltage 4 Refer to wiring diagram and correct 5 Have the unit repaired by a qualified service tech...

Page 17: ...83 0 552 MPa 2 Replace syrup supply 3 Fasten connector tightly 4 Straighten or replace lines 5 Replace BIB pump BIB pump operated but no flow 1 Leak in syrup inlet or outlet line 2 Defective BIB pump...

Page 18: ...nator timer Again measure continuity of the PCB screw lug connections Terminal 3 to 4 Carbonator During the first 2 5 to 3 5 minutes there should be continuity After 2 5 to 3 5 min utes there should b...

Page 19: ...19 INTENTIONALLY LEFT BLANK...

Page 20: ...20 ILLUSTRATIONS AND PART LISTINGS Max II Assembly 1 11 2 3 18 17 19 15 SEE SECTION 6 3 4 10 8 9 6 7 15 16 5 12 14 13...

Page 21: ...x 0 375 13 04 0074 Nut Clip 10 24 14 04 0236 Screw 10 24 x 0 375 Optional Merchandising Panels 15 05 2389 Left and Right Lens Wrapper 16 05 2391 Left Wrapper 17 05 2393 Back Wrapper 18 05 2394 Back Le...

Page 22: ...ck Assembly 26 34 33 32 31 30 29 28 27 35 36 40 39 37 47 46 42 43 44 44 44 43 42 41 14 48 51 53 50 52 49 14 14 24 24 25 25 55 3 4 13 22 20 2 1 6 7 54 8 23 5 19 21 38 18 14 14 11 56 58 59 58 15 10 14 1...

Page 23: ...ion Seal 24 04 0032 01 Nut Nylok 1 4 20 25 04 0033 01 Washer Flat 0 281 ID 26 83 0071 Compressor R 134A 115 V 60 Hz Domestic 83 0076 Compressor R 134A 230 V 50 60 Hz Export 27 02 0114 Grommet Item Par...

Page 24: ...24 Cabinet Assembly 27 26 28 1 2 3 7 5 4 13 8 9 10 11 3 14 15 3 3 17 18 19 16 20 21 22 23 3 24 25 26 12 6 3...

Page 25: ...12 06 0851 Label Overflow R 13 30 5850 Plate Bottom R 14 30 5221 02 Leg Bracket Assembly R 15 81 0112 Legs R 16 30 0319 Splash Plate R 17 82 1312 Drain Assembly R 18 04 0068 Screw 10 24 x 0 375 FH Mac...

Page 26: ...1 4 20 x 1 000 Round Head R 8 04 0711 Cap Plug R 9 06 0856 Water Fill Label R 10 89 0014 Cover Hole Item Part No Description 11 86 0085 Pump 100 GPH R 12 07 0017 Clamp with Screw R 13 REF Carbonator...

Page 27: ...Nut 7 18 18 UNS R 3 07 0481 01 Bracket Regulator 4 01 0446 Fitting Barb R 5 04 0504 Screw 8 18 x 0 375 AB R 6 07 0438 Clamp Oetiker R 7 08 0264 Tubing 0 375 ID R 8 01 0234 Stem Hose 3 8 R 9 01 0232 Nu...

Page 28: ...28 Carbonator Water Syrup Line Assemblies 21 19 20 15 16 10 14 13 12 11 8 9 7 6 5 4 17 8 9 10 4 7 4 29 28 6 3 2 1 19 30 31 32 9 33 34 35 9 36 27 25 9 26 24 18 9 9 7 6 9 7 6 8 17 23 22 8 17 4 17...

Page 29: ...cription R 19 04 0082 Nut 10 24 R 23 1388 Water Cage Assembly R 20 23 0767 Cage Assembly Water R 21 48 2375 Tube Assembly Water R 17 0485 Double Check Valve Assembly R 22 01 1466 Fitting Check Valve R...

Page 30: ...ts Only 6 52 2061 Lead Assembly EIBC 7 12 0190 Terminal Block 8 04 0477 Screw 8 32 x 0 375 Item Part No Description 9 04 0504 Screw 8 16 x 0 375 10 30 5108 01 Cover Control Box 11 11 0186 Jumper 4 Pos...

Page 31: ...11 3 W 10 9 1 B B W B W B 1 4 B W B W B G 9000 and 9100 Series Only COMPRESSOR J3 TERM2 PCB IBC TERM3 B J2 OUT IN IN TERM1 B B J4 OUT B R G B R G W B G B W G R B B W CARBONATOR W TO PLAIN WATER VALVE...

Page 32: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...