background image

6

INSTALLATION

Unpacking the Dispenser

1. 

Set shipping carton upright on the floor then cut package 

banding straps and remove.

2.  Open top of carton and remove interior packaging. 
3.  Lift carton up and off of the unit.
4. 

Remove plywood shipping base from unit by moving unit so 

that one side is off the counter top or table allowing access 

to screws on the bottom of the plywood shipping base.

6.  If leg kit has been provided, assemble legs by tilting unit.

 

If unit is to be transported, it is advisable to leave the 

unit secured to the plywood shipping base.

 

NOTE

 

Inspect unit for concealed damage. If evident, notify 

delivering carrier and file a claim against the same.

NOTE

 

DO NOT LAY UNIT ON ITS SIDE OR BACK

ATTENTION

5. 

Remove accessory kit and loose parts from ice  

compartment.

This manual was developed by Lancer Worldwide as a reference guide for the owner/operator and installer of this dispenser. Please 

read this manual before installation and operation of this dispenser. See pages 19 - 23 for troubleshooting or service  

assistance. If the service cannot be corrected please call your Service Agent or Lancer Customer Service. Always have your model 

and serial number available when you call. 

Read This Manual

Inspection of Drain Spider

 

The drain spider is located directly in the center of the bin under the ice shroud. The cold plate has a cavity designed to 

hold the drain spider. During shipment or installation, the drain spider may become dislodged from its original position. 

Prior to installing the dispenser, ensure the drain spider is in the correct position. This will prevent drain clog issues. 

Inspect the lower bin area and reach under the shroud to ensure the drain spider is secure in the

 

cold plate cutout. If 

the drain spider is not in place, proceed with the following steps:

NOTE

1.  Remove agitator clip and pin from agitator bar.

2. 

Remove agitator bar from paddle wheel (see figure below, 

right side).

3. 

Remove paddle wheel.

4.  Remove ice shroud by lifting back then out of bin.

5. 

Locate drain spider and reinstall in the cold plate cavity 

where drain line exits.

6.  Reinstall all components. Ensure agitator clip is locked. 

Summary of Contents for Flavor Select 22

Page 1: ...k of Lancer 2019 by Lancer all rights reserved FS22 Tech Support Warranty 800 729 1550 email custserv lancerworldwide com web lancerworldwide com Lancer PN 28 0580 04 Revision 04 6 4 8 21 Operation Ma...

Page 2: ...ot Pump Troubleshooting 23 ILLUSTRATIONS AND PART LISTINGS 24 31 Main Unit Assembly 24 25 Ice Chute Assembly 26 Pellet Ice Bin Assembly Conversion Kit PN 82 6285 27 Lancer Flow Control Valve LFCV 28 P...

Page 3: ...used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should service internal components of electrical control housing WARNING Make sure...

Page 4: ...Empty w out Ice 280 lbs 127 kg Full w Ice 480 lbs 218 kg Ice Capacity 200 lbs 91 kg Ice Dispensable 170 lbs 77 kg ELECTRICAL 115 VAC 60 Hz 7 0 Amps 220 230 VAC 50 60 Hz 3 5 Amps FITTINGS Water for Car...

Page 5: ...r CO2 Tank Beverage Dispenser Beverage Tubing Oetiker Clamp Fittings Water Booster Lancer PN 82 3401 or MC 163172 Water Regulator supplied with unit CONSIDER THE FOLLOWING BEFORE INSTALLATION Location...

Page 6: ...dispenser See pages 19 23 for troubleshooting or service assistance If the service cannot be corrected please call your Service Agent or Lancer Customer Service Always have your model and serial numb...

Page 7: ...aker on the dispenser use a bin thermostat to control the ice level see below This will prevent damage to the dispensing mechanism The bracket for mounting a thermostat is located in the ice bin Durin...

Page 8: ...inlets at the front of the unit 6 Install tee fitting to water line to split water line between the carbonated and plain water inlets A B D C A Tee Fitting B Line to Plain Water Inlet C Line to Carb...

Page 9: ...BIB Connector A B 18 Attach BIB connectors on syrup supply line to BIB Repeat for each syrup line pump 19 Install the threaded drain fitting included in accessory kit to drain spout at back of drip t...

Page 10: ...ll syrup pumps ATTENTION Installing CO2 Supply 2 Connect appropriate CO2 tubing to inlet on regulator then route tubing from the CO2 regulator to the CO2 inlet at the unit 6 Turn the knob on the CO2 r...

Page 11: ...lready done so and turn the switch to the ON position 10 Activate each valve until the carbonator pump comes on Release the button allow carbonator to fill and stop Repeat this process until a steady...

Page 12: ...ewdriver to adjust the flow rate if needed Use the Plumbing Diagram on page 29 for reference 13 Using a Lancer ratio cup activate the plain water valve to verify water flow rate 5 oz in 4 sec 15 Repea...

Page 13: ...used must be followed Use sanitary gloves when cleaning the unit and observe all applicable safety precautions DO NOT use a water jet to clean or sanitize the unit DO NOT disconnect water lines when c...

Page 14: ...from the dispenser as instructed Avoid getting sanitizing solution on circuit boards Do not use strong bleaches or detergents these can discolor and corrode various materials Do not use metal scrapers...

Page 15: ...surfaces of the ice chute and the ice chute feed through 13 Repeat Step 6 for all exterior surfaces of the dispenser 14 Using hot water thoroughly rinse away the cleaning solution 15 Wearing sanitary...

Page 16: ...r Let sit for ten 10 minutes 10 Reconnect syrup lines to BIB s and draw drinks to flush solution from the dispenser 11 Taste the drink to verify that there is no off taste If off taste is found flush...

Page 17: ...r left on Sub Category Menu Changes values numbers letters Enter on Sub Category Menu Save Changes Cancel Exit menu NOTE Valves can be adjusted by scrolling through the menus see figure above using th...

Page 18: ...Y and press ENTER 2 Choose the Valve number 1 4 by scrolling UP and DOWN arrows 3 Use the LEFT and RIGHT arrows to shift to the Top Middle or Bottom bonus flavors categories 4 Press the UP and DOWN ar...

Page 19: ...e cycles 9 Place dispenser back into service Carbonator Pump Modifications 1 Turn off power to the dispenser 2 Remove drip tray and splash plate 3 Turn off water 4 Turn the CO2 off activate the relief...

Page 20: ...on the power supply or momentarily unplugging unit 3 Check connections of liquid level probe to PCB assembly 4 Replace PCB assembly 5 Replace liquid level probe 6 Replace pump Excessive foaming 1 No i...

Page 21: ...psi 0 552 MPa min 70 psi 0 483 MPa Do not exceed manufacturer s recommenda tions 2 Open shutoff fully 3 Remove syrup flow control from valve and clean out any foreign material to ensure smooth spool m...

Page 22: ...Agitator pin is missing or damaged 3 Poor ice quality 4 Key not installed on agitation shaft 1 Fill dispenser with ice 2 Replace agitator pin 3 Service ice machine 4 Install key on agitation shaft No...

Page 23: ...B connector if still leaking then replace line 2 Replace o ring 3 Replace defective pump BIB pump fails to restart after bag replacement 1 BIB connector not on tightly 2 BIB connector is stopped up 3...

Page 24: ...24 Main Unit Assembly ILLUSTRATIONS AND PART LISTINGS 1 2 5 6 3 4 9 10 7 8 11 12 14 15 35 34 13 27 28 28b 29 25 26 30 31 32 33 16 17 18 19 20 21 24 22 23 36...

Page 25: ...3 1373 Agitator Assembly FS IBD HEX 18 54 0472 Rear Agitator Bearing IBD 19 10 0762 Pin Hex Design FS 20 03 0368 Agitator Retainer Pin IBD 21 82 3556 Dispensing Wheel Assembly HEX 22 05 1467 Back Lid...

Page 26: ...05 Lower Ice Chute 3 05 0999 02 Ice Chute Lever IBD 4 04 0268 Screw 6 19 x 0 625 LG PLSTI HHSW W 5 03 0241 Ice Chute Spring IBD 6 12 0244 Switch SPST 5A 250V MDM 7 05 0359 01 Bushing 123 ID x 187 OD N...

Page 27: ...et Ice Shield 30 3 82 3651 Dispensing Wheel Assembly Pellet Ice 4 10 0762 Agitator Pin 5 03 0368 Agitator Pin Retainer 6 23 1401 01 Helical Agitator Assembly 7 05 2993 02 Ice Shroud Bin Liner 30 15 00...

Page 28: ...SYRUP ASSY 82 3824 LFCV 3 0 4 5 SODA WATER ASSY LFCV KIT 82 4020 01 LFCV REBUILD KIT Lancer Flow Control Valve LFCV LFCV SPARE PARTS Item Part No Description 1 10 0870 01 Plug Nut Solenoid 2 pack 2 02...

Page 29: ...V1 YEL BLK RED BLK BRN BLK YEL GRY V A L V E M O U N T I N G N O Z Z L E P A N E L I N L E T F I T T I N G S BLU BLK RED GRY S1 3 SODA1 WATER1 S1 4 S1 2 S1 1 IS1 1 IS1 2 IS1 3 VALVE HARNESS DIAGRAM BL...

Page 30: ...NICATING PROBE ICE SWITCH NOZZLE NOZZLE V2 V1 BLACK BLACK WHITE BLACK WHITE BLACK POWER SUPPLY CONTROLLER BOARD DISPLAY CARB AGI FOT COMM ICE OPTIC ICE DOOR ICE SWITCH KEY SOLD OUT JV1 JV2 JV3 JV4 CAR...

Page 31: ...22 20 1 8 15 16 30 1 2 23 18 5 8 1 5 8 7 1 2 1 1 2 3 DIAMETER OPTIONAL 3 18 11 7 1 2 2 F R O N T O F D I S P E N S E R OPTIONAL HOLES FOR FASTENING DISPENSER TO COUNTER WITH SCREWS CUT OUT DASHED ARE...

Page 32: ...Lancer Worldwide 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancerworldwide com lancerworldwide com...

Reviews: