INSTALLATION
Unpacking the Dispenser
1.
Set shipping carton upright on the floor then cut package
banding straps and remove.
2. Open top of carton and remove interior packaging.
3. Lift carton up and off of the unit.
4.
Remove plywood shipping base from unit by moving unit so
that one side is off the counter top or table allowing access
to screws on the bottom of the plywood shipping base.
6. If leg kit has been provided, assemble legs by tilting unit.
If unit is to be transported, it is advisable to leave the
unit secured to the plywood shipping base.
NOTE
Inspect unit for concealed damage. If evident, notify
delivering carrier and file a claim against the same.
NOTE
DO NOT LAY UNIT ON ITS SIDE OR BACK
!
ATTENTION
5.
Remove accessory kit and loose parts from ice
compartment.
This manual was developed by Lancer Worldwide as a reference guide for the owner/operator and installer of this dispenser. Please
read this manual before installation and operation of this dispenser. See pages 19 - 23 for troubleshooting or service
assistance. If the service cannot be corrected please call your Service Agent or Lancer Customer Service. Always have your model
and serial number available when you call.
Read This Manual
Inspection of Drain Spider
The drain spider is located directly in the center of the bin under the ice shroud. The cold plate has a cavity designed to
hold the drain spider. During shipment or installation, the drain spider may become dislodged from its original position.
Prior to installing the dispenser, ensure the drain spider is in the correct position. This will prevent drain clog issues.
Inspect the lower bin area and reach under the shroud to ensure the drain spider is secure in the
cold plate cutout. If
the drain spider is not in place, proceed with the following steps:
NOTE
1. Remove agitator clip and pin from agitator bar.
2.
Remove agitator bar from paddle wheel (see figure below,
right side).
3.
Remove paddle wheel.
4. Remove ice shroud by lifting back then out of bin.
5.
Locate drain spider and reinstall in the cold plate cavity
where drain line exits.
6. Reinstall all components. Ensure agitator clip is locked.