L. Check
o
Brix as required (refer to Section 1.10).
M. Slide control panel into control housing and tighten both captive screws finger tight.
6.13 REGULATOR ASSEMBLY
A. Unplug unit power cord from electrical outlet.
B. Remove drip tray, dispensing paddles and splash plate.
C. Close inlet water shut off valve.
D. Remove tube assembly from inlet of regulator assembly. USE A BACKUP WRENCH TO
PREVENT DAMAGE TO STRAINER.
E. Loosen nuts on outlet fitting.
F. Remove nut on mounting bracket.
G. Remove regulator assembly.
H. Repair or replace defective parts. Use approved thread sealant.
I.
Replace regulator assembly and connect inlet water shut off being careful to include flare seal
washer.
J. Tighten nuts on copper outlet tube 1/4 turn after finger tight. Open inlet water shut off valve and
check for leaks.
K. Remove cap on test connection on bottom of repaired or new regulator and connect test gauge.
L. Replace dispensing paddle.
M. Turn key switch
ON
.
N. Dispense one (1) six (6) ounce (177.4 ml) drink and discard. Set regulator at 25 PSIG
(1.76 kg/cm
2
) flowing while activating the dispensing paddle.
O. Remove test gauge and replace test connection cap.
P. Reassemble unit.
Q. Check
o
Brix and adjust as necessary (refer to Section 1.10).
6.14 VACUUM BREAKER
A. Close inlet water shut off valve.
B. Remove lid over agitator deck.
C. Remove vacuum breaker by loosening adaptor nut on top side of tank assembly.
D. Remove cap from end of vacuum breaker.
CAUTION
USE ONLY LANCER LUBE. USE OF OTHER GREASE, LUBRICANT OR COMPOUNDS MAY
CAUSE OFF TASTE, ODOR AND/OR DAMAGE TO UNIT AND WILL VOID WARRANTY.
E. Inspect umbrella check valve and o-rings. Replace as necessary and reassemble. Lubricate
o-rings only with Lancer Lube.
F. Open inlet water shut off valve and check for leaks.
G. Dispense several drinks while observing vacuum breaker.
NO WATER SHOULD COME OUT
OF HOLE ON END OF VACUUM BREAKER CAP.
6.15 ICE BANK CONTROL
WARNING
DISCONNECT THE POWER CORD FROM THE ELECTRICAL OUTLET.
A. Remove lid over agitator deck.
B. Unplug wiring harness from agitator deck.
C. Remove black rubber seal from retainer (around the ice bank control capillary tube).
D. Pour about 12 ounces (354.8 ml) warm (
NOT HOT
) water into retainer to melt ice around
control bulb.
E. Pull control bulb out of retainer.
F. Disconnect control from wiring harness.
G. Remove one (1) screw and loosen one (1) screw holding control bracket to agitator deck.
Remove defective control.
Control is
NOT
repairable.
H. Install new control.
MAKE SURE CONTROL BULB IS ALL THE WAY DOWN INTO RETAINER
.
I.
Replace black rubber seal.
J. Remove four (4) screws holding agitator motor bracket to agitator deck.
K. Pull agitator motor up so that propeller can be inspected. If any blades are broken due to ice
bank freeze up, replace propeller.
12