background image

6

Installing CO

2

 Supply

1.  Connect high pressure CO

2

 regulator assembly to CO

2

     

cylinder or bulk system.

Thread regulator nut on to tank, then   

 

tighten nut with wrench

A. CO

2

 Regulator

B. Outlet

C. Wrench

D. CO

Supply

A

B

C

D

 

Before installing regulator, assure that a seal (washer 

or o-ring) is present in regulator attachment nut.

ATTENTION

2.  Connect a 1/4” nut, stem and seal to CO

2

 regulator outlet.

3.  Route appropriate tubing from the low pressure CO

2

         

regulator manifold location to the 1/4” nut, stem on the high 

pressure CO

2

 regulator attached to source and connect 

tubing.

A. CO

2

 Regulator

B. 1/4” Nut, Stem & Seal

C. Line to CO

2

 Regulator  

     Manifold

D. Oetiker Pliers

A

B

C

D

 

A dedicated CO

2

 regulator is required to supply the CO

2

 

inlet at the unit as well as to all syrup pumps. 

ATTENTION

6.  Using a wrench, loosen lock nut on the regulator adjustment 

screw of the high pressure CO

2

 regulator connected to the 

source, then using a screwdriver back out lock nut screw all 

the way.

4.  Connect tubing routed from the CO

2

 inlet at the unit to one of 

the low pressure CO

2

 regulator manifold outlets.

5.  Connect tubing routed from the tee at the syrup pumps to 

the second outlet of the low pressure CO

2

 regulator manifold. 

A

B

C

D

A. Line to Dispenser

B. Line to Syrup Pumps

C. Line to CO

2

 Regulator

D. CO

2

 Regulator Manifold

 

DO NOT TURN ON CO

2

 SUPPLY AT THIS TIME

WARNING

7.  Repeat Step 6 on the previous page for both low pressure 

CO

2

 regulators on the regulator manifold routed to the unit 

and the syrup pumps.  

A. CO

2

 Regulator

B. Screwdriver

C. Loosened Lock Nut

D. Regulator Adjustment Screw

A

B

C

D

Dispenser Setup

1.  Turn on water source.
2.  Open the pressure relief valve located on the front of the 

unit, by flipping up on the valve cap lever. Hold open until 

water flows from the relief valve then close (flip down) the 

relief valve.

3. 

Verify all Bag-In-Box contains syrup and check all            

connections for leaks.

4. 

Place enough ice in the ice bin to fill approximately 1/2 of the 

bin before plugging in the unit.

5.  Connect unit power cord to grounded electical outlet. 

A. Pressure 

    Relief Valve

B. CO

2

 Inlet

C. Valve Lever

A

B

C

 

The dispenser must be properly electrically grounded 

 

to avoid serious injury or fatal electrical shock. The 

 

power cord has a three-prong grounded plug. If a 

 

three-hole grounded electrical outlet is not available, 

use an approved method to ground the unit. Follow all 

local electrical codes when making connections. Each 

 

dispenser must have a separate electrical circuit. Do 

 

not use extension cords. Do not connect multiple

 

electrical devices on the same outlet.

WARNING

Summary of Contents for Blue Star IBD CB Series 22

Page 1: ...lancercorp com for immediate access or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if availa...

Page 2: ...arbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3 8 inch barb CO2 Inlet 3 8 inch barb ELECTRICAL 115 VAC 60 Hz 3 6 Amps 230 VAC 50 60 Hz 1 5 Amps PLAIN WATER SUPPLY Mi...

Page 3: ...he 25 8 valve dispensers have space restrictions so the two center valves are plumbed only for carbonated watered drinks and are non adjustable NOTE A B C E A Plain Water ON D Water Closed B Carb Wate...

Page 4: ...ed location should be able to support the weight of the dispenser ice and possibly an icemaker being installed after counter cut out is made Total weight with icemaker for this unit could exceed 800 p...

Page 5: ...et of the proper voltage and amperage rating DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL OUTLET AT THIS TIME Make sure that all water lines are tight and unit is dry before making any electrical connect...

Page 6: ...2 regulator manifold A B C D A Line to Dispenser B Line to Syrup Pumps C Line to CO2 Regulator D CO2 Regulator Manifold DO NOT TURN ON CO2 SUPPLY AT THIS TIME WARNING 7 Repeat Step 6 on the previous p...

Page 7: ...isting counter clockwise and pulling down then remove diffuser by pulling down 5 Install Lancer yellow syrup seperator PN 54 0031 in place of nozzle The pump deck has a 3 minute timeout feature If the...

Page 8: ...es when cleaning and sanitizing syrup lines to avoid contamination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects ste...

Page 9: ...10 Wearing sanitary gloves soak and clean cloth towel in Sanitizing Solution and wash all surfaces of removable parts sides of the Ice Bin Auger and surface of the aluminum casting 11 Using the Saniti...

Page 10: ...to flush solution from the dispenser 11 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again 9 Place syrup lines into sanitizing solution and activate ea...

Page 11: ...hown Syrup Lines Not Shown 30 10 Valve To prevent possible harm to the environment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product...

Page 12: ...WIRING DIAGRAM Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...