Installing CO
2
Supply
1. Connect high pressure CO
2
regulator assembly to CO
2
cylinder or bulk system.
-
Thread regulator nut on to tank, then
tighten nut with wrench
A. CO
2
Regulator
B. Outlet
C. Wrench
D. CO
2
Supply
A
B
C
D
Before installing regulator, assure that a seal (washer
or o-ring) is present in regulator attachment nut.
!
ATTENTION
2. Connect a 1/4” nut, stem and seal to CO
2
regulator outlet.
3. Route appropriate tubing from the low pressure CO
2
regulator manifold location to the 1/4” nut, stem on the high
pressure CO
2
regulator attached to source and connect
tubing.
A. CO
2
Regulator
B. 1/4” Nut, Stem & Seal
C. Line to CO
2
Regulator
Manifold
D. Oetiker Pliers
A
B
C
D
A dedicated CO
2
regulator is required to supply the CO
2
inlet at the unit as well as to all syrup pumps.
!
ATTENTION
6. Using a wrench, loosen lock nut on the regulator adjustment
screw of the high pressure CO
2
regulator connected to the
source, then using a screwdriver back out lock nut screw all
the way.
4. Connect tubing routed from the CO
2
inlet at the unit to one of
the low pressure CO
2
regulator manifold outlets.
5. Connect tubing routed from the tee at the syrup pumps to
the second outlet of the low pressure CO
2
regulator manifold.
A
B
C
D
A. Line to Dispenser
B. Line to Syrup Pumps
C. Line to CO
2
Regulator
D. CO
2
Regulator Manifold
DO NOT TURN ON CO
2
SUPPLY AT THIS TIME
!
WARNING
7. Repeat Step 6 on the previous page for both low pressure
CO
2
regulators on the regulator manifold routed to the unit
and the syrup pumps.
A. CO
2
Regulator
B. Screwdriver
C. Loosened Lock Nut
D. Regulator Adjustment Screw
A
B
C
D
Dispenser Setup
1. Turn on water source.
2. Open the pressure relief valve located on the front of the
unit, by flipping up on the valve cap lever. Hold open until
water flows from the relief valve then close (flip down) the
relief valve.
3.
Verify all Bag-In-Box contains syrup and check all
connections for leaks.
4.
Place enough ice in the ice bin to fill approximately 1/2 of the
bin before plugging in the unit.
5. Connect unit power cord to grounded electical outlet.
A. Pressure
Relief Valve
B. CO
2
Inlet
C. Valve Lever
A
B
C
The dispenser must be properly electrically grounded
to avoid serious injury or fatal electrical shock. The
power cord has a three-prong grounded plug. If a
three-hole grounded electrical outlet is not available,
use an approved method to ground the unit. Follow all
local electrical codes when making connections. Each
dispenser must have a separate electrical circuit. Do
not use extension cords. Do not connect multiple
electrical devices on the same outlet.
!