background image

4

PRE-INSTALLATION

Unpack the Dispenser

1.  Set shipping carton upright on the floor then cut package 

banding straps and remove.

2.  Open top of carton and remove interior packaging. 
3.  Lift carton up and off of the unit.
4.  Remove plywood shipping base from the bottom of the unit. 

(Support dispenser while removing shipping base.)

Inspection of Drain Spider

 

DO NOT LAY UNIT ON ITS SIDE OR BACK

ATTENTION

 

If unit is to be transported, it is advisable to leave the 

unit secured to the plywood shipping base.

 

NOTE

 

The drain spider is located directly in the center of the 

bin under the ice shroud. The coldplate has a cavity 

designed to hold the drain spider. During shipment, the 

drain spider may become dislodged from its original 

position.

NOTE

 

Prior to installing the unit, ensure the drain spider is in 

the correct position. This will prevent drain clog issues. 

Inspect the lower bin area and reach under the shroud  

to ensure the drain spider is secure in the coldplate 

cutout. If the spider is not in place, proceed with the 

following steps:

NOTE

5.  Remove accessory kit and loose parts from ice compartment.

 

Inspect unit for concealed damage. If evident, notify 

 

delivering carrier and file a claim against the same.

NOTE

6.  If leg kit has been provided, assemble legs by tilting unit.

1.  Remove agitator clip (2) and pin (4) from agitator bar (3). 
2.  Remove agitator bar from paddle wheel (5).
3.  Remove paddle wheel.
4.  Remove ice shroud (1) by lifting back then out of the bin.
5.  Locate the drain spider and reinstall in the coldplate cavity 

where the drain line exits.

6.  Reinstall all components. Ensure agitator clip is locked.

Leveling the Dispenser

In order to facilitate proper dispenser drainage and carbonation, 

ensure that the dispenser is level, front to back and side to side. 

Place a level on the top of the rear edge of the dispenser. The 

bubble must settle between the level lines. Repeat this procedure 

for the remaining three sides. Level unit if necessary

Selecting/Preparing Counter Location

1.  Select a level, well ventilated location that is in close       

proximity to a properly grounded electrical outlet, within five 

(5) feet (1.5 m) of a drain, a water supply that meets the 

requirements shown in the Specifications section found on 

pages 4-6, away from direct sunlight or overhead lighting, 

and has sufficient clearance for service and air circulation. 

2.  Sufficient clearance must be provided, if an ice maker is not 

installed, to allow filling ice compartment from a five gallon 

bucket (a minimum of 16 inches is recommended). 

 

The dispenser should only be installed in a location 

where it can be overseen by trained personnel

NOTE

 

Lancer does 

NOT

 recommend the use of shaved or

 

flake ice in the dispenser.

NOTE

AIR

 IN

AIR

 IN

M

INIM

UM

 of

 6

" (1

52 

m

m)

w

all 

cle

aran

ce

MINIMUM

 of 6" (152 mm)

clearance above ice maker

31" (775 mm)

AI

R

 OU

T

AIR

 OUT

AIR OU

T

AIR

 O

UT

MINIMUM

 of 6" (152 mm)

clearance above ice maker

6"

 (1

52 mm

) cle

arance

6" (152

 mm) clear

anc

e

30" (762 mm)

35.5”  (901

.7 mm

)

3.  The selected location should be able to support the weight of 

the dispenser, ice and possibly an icemaker being installed 

after counter cut out is made. Total weight (with icemaker) for 

this unit could exceed 800 pounds (363.6kg).

4.  Unit may be installed directly on countertop or on legs. If 

installed directly on the counter, unit must be sealed to the 

countertop with an FDA approved sealant. If an icemaker is 

to be mounted on top of dispenser, do not install dispenser 

on legs. 

5.  Select a location for the remote pump deck, syrup pumps, 

CO

2

 tank, syrup containers, and water filter (recommended).                                                                                  

6.  Using  Counter  Cutout  Template  provided,  cut  out  required                                                                                      

opening for the water, syrup, and CO

2

 lines in the designated 

dispenser location.

Summary of Contents for Bevariety ACIB 22

Page 1: ...s not a toy Children should not be supervised not to play with appliance It should not be used by children or infirm persons without supervision This appliance is not intended for use by persons inclu...

Page 2: ...local standards It is the responsibility of the installer to ensure compliance Water Notice Units are equipped with an automatic agitation system and will activate unexpectedly Do not place hands or f...

Page 3: ...chilled products 30 only or two chilled and one ambient product on each MVU pad Capable of dispensing flavor shots Replaces the two center LEVs Provides additional carb or non carb beverage flexibili...

Page 4: ...ack and side to side Place a level on the top of the rear edge of the dispenser The bubble must settle between the level lines Repeat this procedure for the remaining three sides Level unit if necessa...

Page 5: ...the left side wall Dispenser Installation The installation and relocation if necessary must be carried out by qualified personnel with up to date knowledge and practical experience in accordance with...

Page 6: ...ocation to the tee fitting at water line 3 Connect line from tee fitting at water line to the remote pump deck inlet regulator 4 Complete the carbonated water line connection installed in the previous...

Page 7: ...aking connections Each dispenser must have a separate electrical circuit Do not use extension cords Do not connect multiple electrical devices on the same outlet WARNING A Regulator Adjustment Screw B...

Page 8: ...ctivate valve to purge syrup until steady flow is achieved 8 Using a Lancer ratio cup activate the valve and capture a sample Verify that the syrup level is even with the water level Use a screwdriver...

Page 9: ...press the Push button one time to change to a non carb beverage 3 Press the same brand button again to change to a carbonat ed beverage light will flash slowly 4 Press the button one more time to chan...

Page 10: ...n to capture a sample Self Serve Crew Serve 8 Verify that the syrup level is even with the water level Use screwdriver to adjust appropriate LFCV if necessary 9 Repeat steps 7 8 for each brand on MVU...

Page 11: ...save 60 seconds after all changes have been made NOTE 5 Repeat Steps 2 4 for each of the desired brands 6 Press the Pour Cancel button to save Cleaning Solution Mix a mild non abrasive detergent e g...

Page 12: ...lush solution from the dispenser Cleaning and Sanitizing Syrup Lines Figal Tank 1 Disconnect syrup inlet from the figal syrup tank 2 Prepare cleaning solution and using a plastic bristle brush scrub b...

Page 13: ...off power to the dispenser 2 Remove Merchandiser 3 Remove Ice Chute Lever then remove Splash Plate Assembly by lifting it up and out from the dispenser face 4 Remove the Ice Chute Assembly base by rem...

Page 14: ...14 WIRING DIAGRAMS ACIB 22 30...

Page 15: ...15 PLUMBING DIAGRAMS ACIB 22 30...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: