CHAPTER 2 ACCES TO TECHNICIAN MENU
NT_820_910_1300_LX_ANG_V1 04_2007.doc
11
2.THE MACHINE TEST
After accessing to technician menu, you must select TEST MACHINE with
////////////////
44444444
4444
4444 ++++++++++++++++
and
////////////////
33333333
3333
3333 ----------------
buttons to test the relay state and the inputs of the
electronic card
Accept with
button.
T E C H N I C I A N M E N U
T e s t
m a c h i n e
Choose the relay number to be checked.
Choose the relay number with
////////////////
44444444
4444
4444 ++++++++++++++++
and
////////////////
33333333
3333
3333 ----------------
buttons.
Each press on
button activates or inactivates the relay.
To leave the relay test, select relay 0 and validate with
button.
T e s t
m a c h i n e
R e l a y
N ° 0 1 : O F F
Particular case :
The "ON" position of relay 14 is limited to 5 seconds to avoid damaging
the heating element if heating without water.
It is necessary to have a quantity of water in the bottom of the basin to
check the functioning of the heaters.
The following display enables to control the state of inputs.
Conformity of the inputs :
INPUT 1 and 2 : CHAMBER FULL
INPUT 3 : CHEMICAL TANKS FULL
INPUT 4 : DOOR LOCKING
INPUT 5, 6 and 7 : N/A
A value of "1" indicates that the switch is closed and the input is
connected to ground (On). A value of "0" indicates that the switch is
open and that the input is not connected to ground (Off).