815 LX / UTILIZATION
CHAPTER 5 PROBLEMS
47
N°3 H
EATING EXCESS
.
F
A
U L T
n
°
0 3
H E A T
I N G
E X C E S S
Heating Excess Definition :
Is displayed if the basin temperature exceeds the programmed temperature
by 20°C.
Corrective Action :
Verify that the incoming water temperature does not exceed the
programmed setpoint temperature.
CONTACT A MAINTENANCE TECHNICIAN.
N°4 H
EATING FAULT
.
F
A
U L T
n
°
0 4
H E A T
I N G
F A U L T
Heating Fault Definition :
This message is displayed during one of the heating phases if the water
temperature has not increased after 8 minutes of heating duration.
Corrective Action :
CONTACT A MAINTENANCE TECHNICIAN TO CHECK :
- the electrical connections,
- the condition of heating elements,
- the safety thermal cut-out with manual reset.