Top Off Programming
•
Place a cup underneath the nozzle.
•
To enter programming mode, touch the small and extra large sizes at the
same time.
•
To set the portions, touch the corresponding portion size button until the
desired liquid level is obtained.
NOTE: There is a timeout feature that will exit programming mode after
25.5 seconds of continuous pouring or 25.5 seconds of inactivity. If
timeout occurs, all data will be retained; however you must re-enter
programming mode to set any remaining sizes.
•
To set the top off portion, let foam settle and touch the same portion
button again until the cup is full.
•
To exit programming mode, touch the pour/cancel button.
4. Cleaning and Sanitizing
4.1. Daily Cleaning
NOTE: Nozzle and Diffuser must be cleaned daily.
•
Remove nozzle by twisting counter clockwise and pulling
down.
•
Remove diffuser by pulling down.
•
Rinse nozzle and diffuser with warm water.
•
Wash nozzle and diffuser with mild cleaning solution in
warm water. Ensure that cleaning solution is thoroughly
rinsed from nozzle and diffuser. Residual solution will
cause foaming and off taste in finished product.
•
Reinstall diffuser and nozzle.
NOTE: Ensure compliance with the instructions of the dispenser manufacturer to properly
clean and sanitize the nozzle and diffuser and ensure no off-taste is present.
4.2. Bi-Weekly Sanitising
•
Nozzle and diffuser must be sanitized bi-weekly. Comply with the instructions of the dispenser
manufacturer to properly sanitize the nozzle and diffuser, and ensure no off-taste is present.