background image

 

www.lancerbeverage.com 

 

 

 

 

 

 

 

Installation, Operation & 

Service Manual 

 

 

VERSAPOUR VALVES 

Summary of Contents for 21000165

Page 1: ...www lancerbeverage com Installation Operation Service Manual VERSAPOUR VALVES ...

Page 2: ...lity for the unit Upon receiving the unit carefully inspect the carton for visible damage If damage exists have the carrier note the damage on the freight bill and file a claim with carrier Responsibility for damage to the dispenser lies with the carrier The installation and relocation if necessary of this product must be carried out by qualified personnel with up to date safety and hygiene knowle...

Page 3: ...e VersaPour is a post mix valve that utilizes electrical and mechanical components to actuate the paddle arms and combine syrup and carbonated plain water to dispense the finished beverage 1 3 Specifications Actuations Self Serve Push Button Portion Control Lever Flowing Pressures at Valve Minimum Water Soda 40 PSIG 0 276 MPA Syrup Sugar 20 PSIG 0 138 MPA Syrup Diet 20 PSIG 0 138 MPA Maximum Water...

Page 4: ...omplete depressurization of water and syrup in the system CO2 will still flow from the valve after water and syrup are emptied Turn OFF CO2 at the supply Operate each valve to depressurize CO2 from the lines Remove existing valve and mounting block Reuse the mounting block screws 3 2 Installation of Valve Caution If dispenser is connected to electrical power the unit must be properly grounded to a...

Page 5: ... screw Slide down I D panel 3 3 Adjust Water Flow NOTE VersaPour Valve The water flow for the Model 100 may be adjusted from 1 25 oz sec 37 ml sec to 2 50 oz sec 74 ml sec The restricted flow adjustment plug Model 100 adjusts to a maximum flow of 2 0 oz sec 59 2 ml sec Slide up I D panel until flow control adjustments are exposed Remove nozzle by twisting counter clockwise and pulling down Remove ...

Page 6: ... valve will pour the appropriate amount determined by the selection in the previous step Flow Rate Setting Place a ratio cup underneath the nozzle Touch the Small and Large size buttons at the same time The valve will pour for five 5 seconds 4 Use the amount poured to adjust flow rate as needed See previous page No Top Off Programming Place a cup underneath the nozzle Slide the ID Panel up on the ...

Page 7: ...ch the same portion button again until the cup is full To exit programming mode touch the pour cancel button 4 Cleaning and Sanitizing 4 1 Daily Cleaning NOTE Nozzle and Diffuser must be cleaned daily Remove nozzle by twisting counter clockwise and pulling down Remove diffuser by pulling down Rinse nozzle and diffuser with warm water Wash nozzle and diffuser with mild cleaning solution in warm wat...

Page 8: ...Hoshizaki Lancer reserve the right to change specifications without notice Images are for illustration purposes only as product may vary No 066 30 October 2017 5 Assembly Diagrams Parts List 5 1 VersaPour Assembly Model 100 SSL PB PC 3 0 oz sec 27 B 27 A ...

Page 9: ...70 21000206 SCR 6 19X 910 PHD PH SL PLT 17 05 1593 02 21051593 DIFFUSER VERSAPOUR 3 0OZ 18 05 3242 21000207 NOZZLE BLACK VERSAPOUR 19 54 0183 04 21000208 NOZZLE ASSY 2 SHOT 4 5OZ S 20 04 0310 21000209 SCR 8 16X 600 PHD PH SL PLT 21 05 0491 01 21000210 FILLER LEV PUSHBUTTON 22 05 0235 21000205 PLUG LARGE 23 05 1109 01 21000211 BODY LOWER PRESSURE 4 5 24 03 0143 21000030 SPRING BANJO VALVE LEV 25 82...

Page 10: ...4 21000010 MOUNTING BLOCK ASSY 82 2658 21822658 3 WAY MOUNTING BLOCK ASSY WATER SODA SYRUP NOT SHOWN 3 05 0266 21000221 STEM VALVE MOUNTING BLOCK 4 05 0267 21000052 WASHER 5 02 0047 79001049 O RING 6 04 0269 79000117 SCREW 7 03 0087 21000222 RETAINER STEM VALVE MNT BLK 8 05 0265 21000026 MOUNTING BLOCK 22 02 0126 79020126 O RING 5 4 Tools PARTS LIST PART NO HL PART NO ALT PART NO DESCRIPTION 54 02...

Page 11: ...etween upper and lower bodies One or more retaining screws loose Paddle arm assemblies are worn or damaged Tighten all six 6 retaining screws Replace paddle arm assemblies Miscellaneous leakage Gap between parts Damaged or improperly installed o rings Tighten appropriate retaining screws Replace or adjust appropriate o rings Insufficient water flow Water flowing pressure is too low or restricted F...

Page 12: ...upplied to valve See SPECIFICATIONS If current is adequate check solenoid coil and switch Replace if necessary Remove valve from mounting block and open stems slightly and check to ensure proper water and syrup supply If no supply check dispenser for freeze up or other problems Water only dispensed no syrup or syrup only dispensed no water Water or syrup stem on mounting block not fully OPEN Impro...

Page 13: ...the Divisional Sales Manager Lancer may choose to reimburse the customer for some or all labour costs associated with a warranty claim Any claim for labour costs must be authorized by Lancer prior to the work being undertaken Exclusions Lancer will not accept any liability or cost associated with any consequential losses such as loss of syrup or beer loss of profit or damage to property as a resul...