background image

Bullet Tower

 24VAC / 50Hz 

 

 

www.lancerbeverage.com 

Page 21 of 34 

Hoshizaki Lancer reserve the right to change specifications without notice. 

Part No: 68000028 

Images are for illustration purposes only as product may vary. 

No 061-2  -  17 December 2019 

9.4  Bullet Tower Customer Standard Assembly 

Height 556mm – 05000256, 05000259, 05000386 & 05000387 

Height 656mm – 05000385 

 

 

 

Summary of Contents for 05000256

Page 1: ...www lancerbeverage com Installation Operation Service Manual BULLET TOWER 24VAC 50Hz ...

Page 2: ...ures 10 3 10 Versapour Portion Control Programming Procedures 12 4 Dispenser Operation 13 4 1 Lever 13 4 2 Push Button 13 4 3 Portion control 13 5 Maintenance 14 5 1 As Needed 14 5 2 Daily Cleaning 14 5 3 Weekly 14 5 4 Monthly 14 5 5 Every Six Months 14 6 Cleaning and Sanitizing 15 6 1 General Information 15 6 2 Cleaning and Sanitizing Solutions 15 6 3 Cleaning and Sanitizing Bag In Box Bib Produc...

Page 3: ...nated H 656mm 05000362 Tower Bullet Customer Versapour 3 oz Push Button Illuminated H 656mm 05000383 Tower Bullet Crew LEV 4 5 oz Portion Control Illuminated H 656mm 1 2 Product Features The Bullet Tower is a beverage dispenser that consists of a stainless steel tube with a 24 VAC Lancer Electric Valve LEV and is intended for countertop installation The Bullet Tower is designed to be supported by ...

Page 4: ...ve 2 Tower Safety Information 2 1 Safety Instructions For your personal safety and that of others working around you please read understand and follow thoroughly all safety instructions included in this manual Review all applicable OSH Occupational Safety Health regulations Learn how to operate the Dispenser and use the controls properly Ensure that the Dispenser is maintained according to service...

Page 5: ...with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Caution The Tower is not suitable for use in subfreezing temperatures To prevent damage to the water s...

Page 6: ...ake full use of the merchandising features of the tower to create maximum impact 3 3 Drip Tray Installation This dispenser is designed to be mounted on a Drip tray on top of a counter or bar Inspect the counter location where the unit is to be installed Verify the selected counter is strong enough to safely support the weight of the installed unit after the cut out for the unit is made Install the...

Page 7: ...lancerbeverage com Page 7 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 3 5 Mounting Holes ...

Page 8: ...inated Towers connect the 24VDC to 24VDC convertor wires to the secondary output of the 24VAC transformer Lancer Transformer 83000451 240 to 24Vac 3A is sold separately and is suitable for supplying up to 3 towers Plug the transformer into a 240VAC 50 Hz outlet protected by an appropriate circuit breaker and Residual Current Device RCD Illuminated Bullet Tower colour adjustment The Acrylic Tube co...

Page 9: ...the chiller has made an icebank The drink temperature should be no higher than 4 4 C 40 F when the brix is set Slide up I D panel until flow control adjustments are exposed see Figure 1 Remove nozzle by twisting counter clockwise and pulling down Remove diffuser by pulling down Install Lancer syrup separator yellow PN 54 0031 for 3Oz valves or Lancer syrup separator smoke PN 54 0201 for 4 5Oz valv...

Page 10: ...e measurement to verify Remove the syrup separator and install the diffuser and nozzle Slide down I D panel 3 9 LEV Portion Control Programming Procedures Lancer Electric Valve The portion control has 5 actuators selections small medium large extra large pour cancel When you touch a selection the conductivity of your finger completes an electrical circuit activating the valve The control also has ...

Page 11: ...g portion button e g Small button highlighted until the desired liquid level is obtained Note If LED goes out during programing all data is retained however you must re enter the programming mode to set any remaining sizes Note Faster blinking indicates a top off is needed Regular blinking indicates that the next size should be entered To top off let the foam settle and then touch the size button ...

Page 12: ...rneath the nozzle Touch the Small and Large size buttons at the same time The valve will pour for five 5 seconds Use the amount poured to adjust flow rate as needed See previous page Press the pour cancel button to stop the pour at any time Programming Portion Size No Top Off Place a cup underneath the nozzle Slide the ID Panel up on the Valve Cover to gain access to Valve LED light located on the...

Page 13: ...ed however you must re enter programming mode to set any remaining sizes To set the top off portion let foam settle and touch the same portion button again until the cup is full To exit programming mode touch the pour cancel button 4 Dispenser Operation 4 1 Lever Fill cup with appropriate amount of ice and place under nozzle Press cup against level to dispense beverage Remove cup to stop 4 2 Push ...

Page 14: ...counter clockwise and pulling down Wash nozzle and diffuser in cleaning solution and then immerse them in a bath of sanitizing solution for 15 minutes Visually inspect around nozzle area for syrup residue This area may be cleaned with warm clean water and a cloth Rinse and air dry the nozzle and diffuser Ensure that cleaning solution is thoroughly rinsed from the nozzle and diffuser Reinstall the ...

Page 15: ...the unit DO NOT disconnect the water lines when cleaning and sanitizing syrup lines to avoid contamination DO NOT spill cleaning and sanitizing solution on any electrical equipment 6 2 Cleaning and Sanitizing Solutions Recommended Preparation of Cleaning Solutions Mix a mild non abrasive detergent e g Sodium Lauretha Sulphate dish soap with clean potable water at a temperature of 32 to 45 C should...

Page 16: ...5 C Place waste container under the dispensing Tap Activate the tap to flush and rinse the line and fittings for a minimum of sixty 60 seconds to remove all traces of cleaning solution Prepare sanitizing solution as described in Section 7 2 Place the end of the syrup inlet line into the container filled with the prepared sanitizing solution Activate the tap and draw sanitizing solution through the...

Page 17: ...com Page 17 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 7 Plumbing Diagram 8 Electrical Circuit Diagram ...

Page 18: ...i Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 Assembly Diagram Parts List 9 1 Bullet Tower Crew Illuminated Assembly 05000283 05000284 05000383 ...

Page 19: ...f 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 2 Bullet Tower Customer Illuminated Assembly 05000279 05000360 05000362 ...

Page 20: ...om Page 20 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 3 Bullet Tower Crew Standard Assembly 05000380 ...

Page 21: ... reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 4 Bullet Tower Customer Standard Assembly Height 556mm 05000256 05000259 05000386 05000387 Height 656mm 05000385 ...

Page 22: ... com Page 22 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 5 Bullet Tower Crew Base Assembly 05000282 ...

Page 23: ...age 23 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 6 Bullet Tower Customer Base Assembly 05000278 05000381 ...

Page 24: ...cerbeverage com Page 24 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 7 LEV Lever Assembly ...

Page 25: ...beverage com Page 25 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 LEV Lever Assembly Continued ...

Page 26: ...beverage com Page 26 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 8 LEV Push Button Assembly ...

Page 27: ...erage com Page 27 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 LEV Push Button Assembly Continued ...

Page 28: ...verage com Page 28 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 9 LEV Portion Control Assembly ...

Page 29: ...age com Page 29 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 LEV Portion Control Assembly Continued ...

Page 30: ...age com Page 30 of 34 Hoshizaki Lancer reserve the right to change specifications without notice Part No 68000028 Images are for illustration purposes only as product may vary No 061 2 17 December 2019 9 10 Versapour Valve Assembly 27 B 27 A ...

Page 31: ...21000206 SCR 6 19X 910 PHD PH SL PLT 17 05 1593 02 21051593 DIFFUSER VERSAPOUR 3 0OZ 18 05 3242 21000207 NOZZLE BLACK VERSAPOUR 19 54 0183 04 21000208 NOZZLE ASSY 2 SHOT 4 5OZ S 20 04 0310 21000209 SCR 8 16X 600 PHD PH SL PLT 21 05 0491 01 21000210 FILLER LEV PUSHBUTTON 22 05 0235 21000205 PLUG LARGE 23 05 1109 01 21000211 BODY LOWER PRESSURE 4 5 24 03 0143 21000030 SPRING BANJO VALVE LEV 25 82 38...

Page 32: ...utoff fully C Remove water soda flow control from upper body and clean out any foreign material to ensure smooth free spool movement Insufficient syrup flow A Insufficient CO2 pressure to BIB pumps B Shutoff on mounting block not fully open C Foreign debris in syrup flow control A Adjust CO2 pressure to 80 PSI minimum 70 PSI for BIB pumps B Open shutoff fully C Remove syrup flow control from upper...

Page 33: ... restriction C Valve flow control stuck A Check incoming syrup to ensure minimum flowing pressure B Check shutoff on mounting block to ensure it is in fully open position C Remove water flow control from upper body and clean out any foreign material to ensure smooth free spool movement Sleeve and spool are marked S D Excessive foaming A Incoming water soda or syrup temperature too high B CO2 press...

Page 34: ...val of the Divisional Sales Manager Lancer may choose to reimburse the customer for some or all labour costs associated with a warranty claim Any claim for labour costs must be authorized by Lancer prior to the work being undertaken Exclusions Lancer will not accept any liability or cost associated with any consequential losses such as loss of syrup or beer loss of profit or damage to property as ...

Reviews: