PAGE 14
•
Remove sump housing using the sump
spanner wrench.
Note:
Be careful as it will be full of water
and heavy. Recommend a bucket or pail
under the sump. If sump is fitted with
a bottom drain port, removing the plug
to drain the system into the bucket is
recommended.
• Remove and discard the used filter
cartridge in accordance with applicable
codes and regulations. Wipe clean the
sump housing with cold water and a soft
sponge.
• Before installing new filter cartridge, make
sure filter housing o-ring seal is properly
seated and shows no sign of visible
damage. Ensure o-ring is lubricated using
silicone based lubricant.
• Open the new filter cartridge wrap
and discard wrap. Insert the new filter
cartridge into the sump housing and
connect to the unit using the sump
spanner wrench.
Note:
Be careful not to overtighten.
•
Plug the electronic ballast controller into
the GFCI outlet and power-up the system.
• Make sure vent-valve is closed.
• Slowly turn on water supply.
•
Vent to purge air, then turn and tighten
vent-valve closed.
• Let water flow for at least 5 minutes
before use.
6
5
4
7
9
8