PAGE 6

WATER SOFTENER

PRESSURE

TANK

BYPASS PLUMBING

RECOMMENDED

IF

OPTIONAL BP2000

BYPASS VALVE

IS NOT USED.

BRINE TANK

FROM

WELL PUMP

MINIMUM 10 FEET

BETWEEN

WATER SOFTENER OUTLET

AND

WATER HEATER INLET

WATER SOFTENER

BYPASS PLUMBING

RECOMMENDED

IF

OPTIONAL BP2000

BYPASS VALVE

IS NOT USED.

TO

DRAIN

TO

OUTSIDE

TAP

BRINE TANK

WATER

HEATER

DRAIN LINE

AIR GAP

ADAPTER

FROM

WATER MAIN

COLD

HOT

MINIMUM 10 FEET

BETWEEN

WATER SOFTENER OUTLET

AND

WATER HEATER INLET

LOCATE WATER SOFTENER

AS CLOSE AS POSSIBLE

TO BRINE TANK.

A SIX FOOT LENGTH OF 3/8" O.D.

BRINE LINE POLYTUBE

SUPPLIED WITH BRINE TANK.

OVERFLOW GRAVITY DRAIN - ONLY USED IN CASE OF MALFUNCTION IN THE BRINE SHUTOFF. DO NOT CONNECT TO CONTROL VALVE DRAIN LINE.

IF UNIT IS INSTALLED WHERE OVERFLOW COULD CAUSE WATER DAMAGE, CONNECT TUBING AND RUN TO FLOOR DRAIN. DO NOT RUN TUBING ABOVE OVERFLOW HEIGHT.

WELL WATER

INSTALLATION

CITY WATER

INSTALLATION

WATER

METER

TO

DRAIN

TO

OUTSIDE

TAP

WATER

HEATER

DRAIN LINE

AIR GAP

ADAPTER

COLD

HOT

LOCATE WATER SOFTENER

AS CLOSE AS POSSIBLE

TO BRINE TANK.

A SIX FOOT LENGTH OF 3/8" O.D.

BRINE LINE POLYTUBE

SUPPLIED WITH BRINE TANK.

LOCATE WATER SOFTENER CLOSE TO A DRAIN.

AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO

PREVENT BACK PRESSURE ON BRINE INJECTOR.

IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS

5 FEET ABOVE CONNECTION ON CONTROL VALVE

OR

IF DRAIN LINE EXCEEDS 20 FEET IN LENGTH,

DRAIN LINE PIPE SIZE SHOULD BE MINIMUM 3/4".

OVERFLOW GRAVITY DRAIN - ONLY USED IN CASE OF MALFUNCTION IN THE BRINE SHUTOFF. DO NOT CONNECT TO CONTROL VALVE DRAIN LINE.

IF UNIT IS INSTALLED WHERE OVERFLOW COULD CAUSE WATER DAMAGE, CONNECT TUBING AND RUN TO FLOOR DRAIN. DO NOT RUN TUBING ABOVE OVERFLOW HEIGHT.

LOCATE WATER SOFTENER CLOSE TO A DRAIN.

AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO

PREVENT BACK PRESSURE ON BRINE INJECTOR.

IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS

5 FEET ABOVE CONNECTION ON CONTROL VALVE

OR

IF DRAIN LINE EXCEEDS 20 FEET IN LENGTH,

DRAIN LINE PIPE SIZE SHOULD BE MINIMUM 3/4".

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

6. The brine refill flow control assembly is installed in an easy to access refill 

elbow  located  on  top  of  the  control  valve.  The  refill  flow  control  assembly  is 

attached to the control valve with a locking clip. The locking clip allows the elbow 

to rotate 270 degrees so the outlet can be oriented towards the brine tank.

7.  Connect  the  brine  line  polytubing  found  with  the  brine  tank  to  the  brine 

connection on the control valve. The control valve has a standard refill elbow 

to which a 3/8” flexible tube can be connected, see

 

below. One polytube insert 

is  shipped  on  the  brine  line  elbow’s  locking  clip.  Remove  this  white  polytube 

insert and replace the locking clip. The second polytube insert is taped to the 

top of the brine well cap in the brine tank. Press the polytube inserts into each 

end of the provided brine tubing, press the polytube with insert into the nut on 

the brine fitting. Tighten nut securely to create a pressure tight connection. The 

nut, gripper and retainer sleeve is a three-piece assembly that can come apart 

from the elbow body. Parts must be reassembled exactly as shown to function 

properly.  If  the  nut  is  completely  removed  from  the  body,  slip  the  nut,  plastic 

gripper and retainer sleeve on to the tube then tighten on to the fitting. Make sure 

the floor is clean beneath the brine tank and that it is level and smooth. Install 

brine tubing to the brine tank using the above instructions.

BRINE LINE FITTING CONNECTIONS

DRAIN LINE FITTING CONNECTION USING 5/8" POLY TUBE

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

Click to buy NOW!

PD

F-XCHANGE

w

ww

.docu-track.c

om

POLYTUBE

8. A 1/2” (inside diameter, not provided) gravity drain line should be connected 

to the overflow fitting on the side of the brine tank. This overflow is in case of a 

malfunction in the brine shut off. If the unit is installed where water may flow in the 

event of an overflow and cause water damage, connect a length of flexible tubing 

and run to a drain below the level of the overflow. 

(Do not connect the tubing to 

the drain line on the control valve. Do not run tubing above overflow height 

at any point.)

A

G

A

F

B

D

C

E

Summary of Contents for X-FACTOR Series

Page 1: ...ars of trouble free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this booklet with your important documents 7 FESLX 24B 7 FESLX 32B 7 FESLX 45B 7 FESLX 60B 7 FESLXC 24B ELECTRONIC IRONSOFT WATER SOFTENER WITH THE X FACTOR CONTROL VALVE PROGRAMMED FOR PRE...

Page 2: ... for each ppm iron for total compensated hardness Use the total compensated hardness number for hardness setting on page 8 Total Grains of Compensated Hardness per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Specifications 2 Pre Installation Review 3 General Installation and Service Warnings 3 Bypass Valve Operation 4 Installation Instructions Diagrams 5 ...

Page 3: ...QUALITY If sand or sediment is present in the water supply a sediment filter should be installed ahead of the water softener Your water softener has been designed to adequately reduce compensated hardness from levels up to 100 grains per gallon Ferrous bicarbonate clear water and or ferric hydroxide red water iron levels up to 10 ppm can also be reduced Ferrous iron is dissolved in water and not v...

Page 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o rings can easily be replaced if service is required The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The handles identify the flow dir...

Page 5: ...rical plumbing should be done in accordance to all local codes INSTALLATION INSTRUCTIONS 5 The drain connection may be made using either 5 8 polytube see below or a 3 4 female adapter The polytube insert is shipped attached to the drain line elbow s locking clip Press the insert into the drain line tubing tubing not provided Loosen the nut of the drain line elbow Press the 5 8 polytube with insert...

Page 6: ...PDF XCHANGE w w w docu track c o m C l i c k t o b u y N O W PDF XCHANGE w w w docu track c o m 6 The brine refill flow control assembly is installed in an easy to access refill elbow located on top of the control valve The refill flow control assembly is attached to the control valve with a locking clip The locking clip allows the elbow to rotate 270 degrees so the outlet can be oriented towards ...

Reviews: